17 research outputs found

    Roles of electric field and fiber structure in cardiac electric stimulation.

    Get PDF
    This study investigated roles of the variation of extracellular voltage gradient (VG) over space and cardiac fibers in production of transmembrane voltage changes (DeltaV(m)) during shocks. Eleven isolated rabbit hearts were arterially perfused with solution containing V(m)-sensitive fluorescent dye (di-4-ANEPPS). The epicardium received shocks from symmetrical or asymmetrical electrodes to produce nominally uniform or nonuniform VGs. Extracellular electric field and DeltaV(m) produced by shocks in the absolute refractory period were measured with electrodes and a laser scanner and were simulated with a bidomain computer model that incorporated the anterior left ventricular epicardial fiber field. Measurements and simulations showed that fibers distorted extracellular voltages and influenced the DeltaV(m). For both uniform and nonuniform shocks, DeltaV(m) depended primarily on second spatial derivatives of extracellular voltages, whereas the VGs played a smaller role. Thus, 1) fiber structure influences the extracellular electric field and the distribution of DeltaV(m); 2) the DeltaV(m) depend on second spatial derivatives of extracellular voltage

    Coronary vein defibrillator coil placement in patients with high defibrillation thresholds

    No full text
    Background: Elevated defibrillation threshold (DFT) occurs in 2%-6% of patients undergoing implantable cardioverter defibrillator (ICD) implantation. Adding a defibrillation coil in the coronary sinus (CS) or its branches can result in substantial reductions in the mean DFT. However, data regarding acute success and long-term stability remain lacking. We report our experience with this bailout strategy. Methods: Patients with elevated DFT at implantation (safety margin at implantation <10 J) and those with failed ICD shocks for ventricular arrhythmias (VA) referred for high DFT underwent placement of an additional defibrillation coil in the CS. DFT testing was performed at the completion of the implantation procedure. External potentially reversible factors were excluded. High-output devices were systematically used. Results: Four patients with high DFT at implantation and two with several failed shock attempts underwent placement of a defibrillation coil in the CS. Mean age was 41.8 (23-78). They presented a mean LVEF of 21% (15-30), QRS-complex duration of 109.8 milliseconds (87-168), body surface area of 1.96 m(2) (1.45-2.58), and a mean R wave of 16.3 mV (8-27). Defibrillation coil implantation in the CS (final shocking configuration of right ventricle as anode and left ventricle (LV) plus can as cathode) was associated with successful DFT testing in all. Three patients had a concomitant LV lead for biventricular pacing. During a mean follow-up of 54.67 months (10-118), two patients experienced successful ICD shocks for VA (one of them also presented inappropriate shocks because of the fast conducting atrial fibrillation). Conclusions: Positioning of a defibrillation coil in the CS can result in a substantial reduction in mean DFT and associates with optimal long-term stability
    corecore