132 research outputs found

    Allocation de SIL requis sur un réseau de refroidissement à l'ammoniac conformément à la norme CEI 61511

    Get PDF
    International audienceThe IEC 61511 standard addresses to safety in the application of safety instrumented systems for the Process Industries. The standard requires to carry out process hazard and risk assessment in order to deduce specifications for the SIS. Two main concepts, fundamental to its application, are underlined : safety lifecycle and safety integrity levels. This article deals more with the safety integrity levels (SIL) and to their allocation depending on the SIS considered. This international standard. describes various quantitative and qualitative methodology for SIL (Safety Integrity Level) allocation. The choice for one or another methodology will depend on various criteria as illustrated in this paper. The paper make a brief description of three spreaded methods in the Process Industries. The selection criteria for each method are presented. Advantages and disadvantages of these various methods are indicated. In order to illustrate the methodology of a SIL allocation, a case study on a storage unit of ammonia is presentedLa norme CEI 61511 s'intéresse à la sécurité fonctionnelle dans l'application des systÚmes instrumentés de sécurité aux industries de production par processus. Elle exige dans ce cadre de conduire une évaluation de danger et de risque des processus pour permettre d'en déduire des spécifications pour les SIS. Deux concepts fondamentaux sont mis en avant : le cycle de vie de sécurité et les niveaux d'intégrité de sécurité. Cet article s'intéresse plus particuliÚrement au niveaux d'intégrité de sécurité (SIL) et à leur allocation en fonction du SIS à évaluer. La norme décrit différentes méthodes d'allocation de SIL (Safety Integrity Level), qu'elles soient qualitatives ou quantitatives. Aucune méthode n'est à privilégier, le choix d'une technique dépendra de différents critÚres. Cet article fait ainsi une brÚve description de trois méthodes répandues dans le secteur des industries de procédés. Nous présentons les critÚres qui orientent le choix d'une méthode et indiquons les avantages et les inconvénients de ces différentes méthodes. Afin d'expliciter le déroulement d'une démarche d'allocation de SIL, une application sur une unité de stockage d'ammoniac est présenté

    Restitution thermodynamique du diagramme de phases du systĂšme binaire Bi-Sb

    Get PDF
    Le prĂ©sent travail s’intĂ©resse au calcul des enthalpies libres de Gibbs relatives aux alliages binaires Bismuth-Antimoine Ă  diffĂ©rentes tempĂ©ratures en se basant sur les donnĂ©es thermodynamiques relevĂ©es dans la littĂ©rature. Ce calcul permet de retracer le diagramme de phases du systĂšme Bi-Sb Ă  l’aide d’un programme, que nous avons Ă©tabli sous l’environnement Matlab avec le polynĂŽme de Redlich – Kister comme modĂšle mathĂ©matique. La rĂ©cupĂ©ration des fractions molaires correspondantes Ă  la tangente commune des courbes d’enthalpie libre des deux phases liquide et solide Ă  diffĂ©rentes tempĂ©ratures n’est possible qu’aprĂšs la rĂ©solution du systĂšme d’équation non linĂ©aire rĂ©sultant par la mĂ©thode de Newton – Raphson. Les solutions reprĂ©sentent les points d’équilibre stable entre les deux phases solide et liquide et qui permettent la reconstruction des courbes de liquidus et solidus du diagramme de phases Bi-Sb. Les rĂ©sultats obtenus sont trĂšs satisfaisants en comparaison avec ceux expĂ©rimentaux de la bibliographie. MOTS CLES :Diagrammes de phases – Solution solide continue – Courbe de liquidus – Courbe de solidus –ModĂ©lisation– Matlab – SystĂšmes non linĂ©aires – Newton-Raphson

    Nulliparity enhances the risk of second primary malignancy of the breast in a cohort of women treated for thyroid cancer

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Many studies have reported an increased risk of developing a second primary malignancy (SPM) of the breast in women treated for thyroid cancer. In this study, we investigated several potential risk factors for this association. The aim of this retrospective cohort study was to identify a subgroup of women surgically treated for papillary thyroid cancer that may benefit from more careful breast cancer screening.</p> <p>Methods</p> <p>A total of 101 women surgically treated for papillary thyroid cancer from 1996 to 2009 with subsequent follow-up were interviewed by phone regarding personal risk factors and lifestyle habits. Only 75 questionnaires could be evaluated due to a 25.7% rate of patients not retrieved or refusing the interview. Data analysis was performed using a multivariate logistic model.</p> <p>Results</p> <p>The standardised incidence ratio (SIR) for breast cancer was 3.58 (95% IC 1.14 - 8.37). Our data suggest a protective effect of multiparity on the development of a SPM of the breast (O.R. 0.15; 95% IC 0.25 - 0.86). Significant associations were not found with other known risk factors including Body Mass Index (BMI), age at first tumour, concurrent metabolic diseases, smoking, physical activity and familiarity.</p> <p>Conclusions</p> <p>This study confirms that a higher incidence of SPM of the breast is observed in women treated for papillary thyroid cancer. Additionally, this risk is increased by nulliparity, thus a strict breast screening program for nulliparous women treated for thyroid cancer may be advisable.</p

    Mitochondrial DNA (mt DNA) A3243G mutation associated with an annular perimacular retinal atrophy

    Get PDF
    RĂ©sumĂ©:Background:La mutation 3243 de 1'ADN mitochondrial est associee avec le syndrome l\/HDD (surdite, diabĂšte transmis par la mĂšre) et le syndrome MELAS (Myopathie, EncĂ©phalopathie, acidose Lactique et attaques cĂ©rĂ©brales). Elle est aussi associe Ă  des troubles cardiaques, digestifs, endo- et exocrines. Nous rapportons deux cas de maculopathie associĂ©e Ă  cette mutation.Histoire et symptomes: pCas l: il s'agit d'une femme de 60 ans soufrant d'un diabĂšte et d'une surditĂ© sans plainte visuelle lors de la prĂ©sentation. Son acuitĂ© visuelle Ă©tait de 10/ l0 des deux yeux.Cas 2: il s'agit d'une femme de 54 ans souffrant d'une surditĂ© et d'un diabĂšte qui se plaint d'une baisse de vision principalement de l'oeil gauche. Son acuitĂ© visuelle Ă©tait de 6/10 pour l'oeil droit et de 0.5/l0 pour l'oeil gauche.Les deux patientes prĂ©sentaient une atrophie choriorĂ©tinienne arĂ©olaire centrale. La patiente 1 a Ă©tĂ© suivie durant plus de 15 ans. Une Ă©volution lente et progressive de la maculopathie a Ă©tĂ© observĂ©e. Lors de la derniĂšre visite, l'acuitĂ© visuelle Ă©tait de 6/ l0 dans les deux yeux. Elle prĂ©sentait un handicap marquĂ© des suites du scotome annulaire.ThĂ©rapie et pronostic:AucunConclusion:Les deux patientes prĂ©sentaient une atrophie rĂ©tinienne annulaire pĂ©rimaculaire. Les patients atteints d'une mutation 3243 de l'ADN mitochondrial devraient bĂ©nĂ©ficier d'un examen du fond d'oeil Ă  la recherche d'une maculopahtie, mĂȘme s'ils sont asymptomatiques.Inversement, la dĂ©couverte d'une telle maculopathie gĂ©ographique devrait suggĂ©rer la possibilitĂ© d'une mutation au locus 3243 de l'ADN mitochondrial, surtout en prĂ©sence d'un diabĂšte et/ou d'une surditĂ©

    Allocations de SIL requis des fonctions instrumentées de sécurité d'une installation lorsque l'analyse de risques est imcomplÚte

    Get PDF
    International audienceThe IEC 61511 standard describes various quantitative and qualitative methodology for SIL (Safety Integrity Level) allocation. The choice for one or another methodology will depend on various criteria as illustrated in this paper. We present the selection criteria of a method and we indicate the advantages and the disadvantages of these various methods. In order to illustrate our methodology, we took the example of an ammonia storage.La norme CEI 61511 décrit différentes méthodes d'allocation de SIL (Safety Integrity Level), qu'elles soient qualitatives ou quantitatives. Aucune méthode n'est à privilégier, le choix d'une technique dépendra de différents critÚres comme le montre cet article. Nous présentons les critÚres qui orientent le choix d'une méthode et indiquons les avantages et les inconvénients de ces différentes méthodes. Une application sur une unité de stockage d'ammoniac est présentée afin d'expliciter notre démarche

    Influence du milieu cryotechnique sur le comportement tribologique des materiaux heterogenes : etude en glissement sec dans l'azote liquide

    No full text
    SIGLECNRS T Bordereau / INIST-CNRS - Institut de l'Information Scientifique et TechniqueFRFranc

    ThĂšse Pharmacie

    No full text
    • 

    corecore