25 research outputs found
Axial electric field component in a fast ionization wave in nanosecond pulsed nitrogen discharge at 20-100 mbar
International audienceThe axial electric field component in a fast ionization wave in ns tube discharge in N2 at 20-100 mbar is measured by ps second harmonic generation with the temporal and spatial resolution of 200 ps and 0.5 mm respectively. From absolute calibration by current shunts, the peak axial electric field, 8-11 kV/cm, shows a weak dependence on pressure, with the peak reduced electric field ≈2000 Td at 20 mbar. For the same voltage conditions, pressure reduction from 100 to 20 mbar steepens the wave front from 3.0 ns to 1.0 ns FWHM
Electric field induced second harmonic (E-FISH) generation for characterization of fast ionization wave discharges at moderate and low pressures
International audienceThe electric field in an ionization wave discharge in nitrogen at 20100 mbar, initiated by positive polarity, high-voltage, ns duration pulses, is measured by ps second harmonic generation. The axial electric field component is determined both during the propagation of the ionization wave along the discharge tube, and after the wave reaches the grounded electrode, spanning the entire discharge gap. The temporal resolution of the present measurements is 200 ps, with the spatial resolution in the axial direction of approximately 0.5 mm. The second harmonic signal exhibits a quadratic dependence on the Laplacian electric field but indicates that in this pressure range most of the signal is generated within the wall of the tube. Absolute calibration of the signal is obtained from the current shunt data, after the ionization wave has reached the grounded electrode. Comparison of the data taken at different pressures shows that the peak value of the axial electric field in the wave front, 811 kV cm−1, has a fairly weak dependence on pressure, with the peak reduced electric field reaching ≈2000 Td at 20 mbar. Reducing the pressure from 100 to 20 mbar, while keeping the discharge pulse voltage waveform the same, steepens the ionization wave front considerably, from 3.0 to 1.0 ns full width at half maximum. The results demonstrate that ps second harmonic generation may be employed for electric field measurements in low-pressure discharges, discharges sustained in small diameter capillary tubes, and discharges sustained in gas mixtures with low nonlinear susceptibility, at the conditions when the detection of the signal generated directly in the plasma is challenging. High temporal resolution of the present measurements indicates a possibility of detection of non-local electron kinetics effects induced by a rapidly v
Towards ultrashort pulse generation from nanosecond laser sources for electric field measurements
International audienc
Characterization of an Optical Pulse Slicer for Gas-Phase Electric Field Measurements Using Field-Induced Second Harmonic Generation
International audienc
Nonequilibrium Modeling of Oxygen in Reflected Shock Tube Flows
Peer Reviewedhttps://deepblue.lib.umich.edu/bitstream/2027.42/140446/1/6.2014-2961.pd
Diagnostic and modeling of fast pulsed discharges
International audienc