196 research outputs found
Dust and grit matter: abrasives of different size lead to opposing dental microwear textures in experimentally fed sheep (Ovis aries)
External abrasives ingested along with the herbivore diet are considered main contributors to dental wear, though how the different sizes and concentrations of these abrasives influence wear remains unclear. Dental microwear texture analysis (DMTA) is an establishedmethod for dietary reconstructionwhich describes a toothâs surface topography on a micrometre scale. The method has yielded conflicting results as to the effect of external abrasives. In the present study, a feeding experiment was performed on sheep (Ovis aries) fed seven diets of different abrasiveness. Our aim was to discern the individual effects of size (4, 50 and 130 ÎŒm) and concentration (0%,4% and 8% of dry matter) of abrasives on dental wear, applying DMTA to four tooth positions. Microwear textures differed between individual teeth, but surprisingly, showed no gradient along the molar tooth row, and the strongest differentiation of experimental groups was achieved when combining data of all maxillary molars. Overall, a pattern of increasing height, volume and complexity of the toothâs microscopic surface appeared with increasing size of dietary abrasives, and when compared with the control, the small abrasive diets showed a polishing effect. The results indicate that the size of dietary abrasives is more important for dental microwear texture traces than their concentration, and that different sizes can have opposing effects on the dietary signal. The latter finding possibly explains conflicting evidence from previous experimental DMTA applications. Further exploration is required to understand whether and how microscopic traces created by abrasives translate quantitatively to tissue loss
Description, Host-specificity, and Strain Selectivity of the Dinoflagellate Parasite Parvilucifera sinerae sp.nov. (Perkinsozoa)
17 pages, 7 figures, 2 tablesA new species of parasite, Parvilucifera sinerae sp. nov., isolated froma bloomof the toxic Dinoflagellate Alexandrium minutum in the harbor of Arenys de Mar (Mediterranean Sea, Spain), is described. This species is morphologically, behaviourally, and genetically (18S rDNA sequence) different from Parvilucifera infectans, until now the only species of the genus Parvilucifera to be genetically analyzed. Sequence anĂĄlisis of the 18S ribosomal DNA supported P. Sinerae as a new species placed within the Perkinsozoa and close to P. infectans. Data on the seasonal occurrence of P. sinerae, its infective rates in natural and laboratory cultures, and intra-species strain-specific Resistance are presented. Life-cycle studies in field simples showed that the dinoflagellate resting zygote (restingcyst) was resistant to infection, but the mobile zygote (planozygote) orpelli clestage (temporary cyst) became infected. The effects of Light and salinity level son the growth of P. sinerae were examined, and the results showed that low salinity levels promote both sporangial germination and higher rates of infection. Our findings on this newly described parasite point to a complex hostâparasite interaction and provide valuable information that leads to a reconsideration of the biological strategy to control dinoflagellate blooms by jeans of intentional parasitic infectionsThis research was funded by the EU Project SEED (GOCE-CT-2005-003875). R.I. Figueroa work is supported by a I3P contract and E. GarcĂ©sâ work is supported by a Ramon y Cajal grant, both from the Spanish Ministry of Education and SciencePeer reviewe
Effect of Anesthesia on Microelectrode Recordings during Deep Brain Stimulation Surgery in Tourette Syndrome Patients
Background: Deep brain stimulation (DBS) is an accepted treatment for patients with medication-resistant Tourette syndrome (TS). Sedation is commonly required during electrode implantation to attenuate anxiety, pain, and severe tics. Anesthetic agents potentially impair the quality of microelectrode recordings (MER). Little is known about the effect of these anesthetics on MER in patients with TS. We describe our experience with different sedative regimens on MER and tic severity in patients with TS. Methods: The clinical records of all TS patients who underwent DBS surgery between 2010 and 2018 were reviewed. Demographic data, stimulation targets, anesthetic agents, perioperative complications, and MER from each hemisphere were collected and analyzed. Single-unit activity was identified by filtering spiking activity from broadband MER data and principal component analysis with K-means clustering. Vocal and motor tics which caused artifacts in the MER data were manually selected using visual and auditory inspection. Results: Six patients underwent bilateral DBS electrode implantation. In all patients, the target was the anterior internal globus pallidus. Patient comfort and hemodynamic and respiratory stability were maintained with conscious sedation with one or more of the following anesthetic drugs: propofol, midazolam, remifentanil, clonidine, and dexmedetomidine. Good quality MER and clinical testing were obtained in 9 hemispheres of 6 patients. In 3 patients, MER quality was poor on one side. Conclusion: Cautiously applied sedative drugs can provide patient comfort, hemodynamic and respiratory stability, and suppress severe tics, with minimal interference with MER. (C) 2019 The Author(s) Published by S. Karger AG, Base
Dental microwear texture analysis correlations in guinea pigs (Cavia porcellus) and sheep (Ovis aries) suggest that dental microwear texture signal consistency is species-specific
Dental microwear texture (DMT) analysis is used to differentiate abrasive dental wear patterns in many species fed different diets. Because DMT parameters all describe the same surface, they are expected to correlate with each other distinctively. Here, we explore the data range of, and correlations between, DMT parameters to increase the understanding of how this group of proxies records wear within and across species. The analysis was based on subsets of previously published DMT analyses in guinea pigs, sheep, and rabbits fed either a natural whole plant diet (lucerne, grass, bamboo) or pelleted diets with or without added quartz abrasives (guinea pigs and rabbits: up to 45 days, sheep: 17 months). The normalized DMT parameter range (P4: 0.69 â 0.25; M2: 0.83 â 0.16) and correlation coefficients (P4: 0.50 â 0.31; M2: 0.63 â 0.31) increased along the tooth row in guinea pigs, suggesting that strong correlations may be partially explained by data range. A comparison between sheep and guinea pigs revealed a higher DMT data range in sheep (0.93 â 0.16; guinea pigs: 0.47 â 0.29), but this did not translate into more substantial correlation coefficients (sheep: 0.35 â 0.28; guinea pigs: 0.55 â 0.32). Adding rabbits to an interspecies comparison of low abrasive dental wear (pelleted lucerne diet), the softer enamel of the hypselodont species showed a smaller data range for DMT parameters (guinea pigs 0.49 â 0.32, rabbit 0.19 â 0.18, sheep 0.78 â 0.22) but again slightly higher correlations coefficients compared to the hypsodont teeth (guinea pigs 0.55 â 0.31, rabbits 0.56 â 0.30, sheep 0.42 â 0.27). The findings suggest that the softer enamel of fast-replaced ever-growing hypselodont cheek teeth shows a greater inherent wear trace consistency, whereas the harder enamel of permanent and non-replaced enamel of hypsodont ruminant teeth records less coherent wear patterns. Because consistent diets were used across taxa, this effect cannot be ascribed to the random overwriting of individual wear traces on the more durable hypsodont teeth. This matches literature reports on reduced DMT pattern consistency on harder materials; possibly, individual wear events become more random in nature on harder material. Given the species-specific differences in enamel characteristics, the findings suggest a certain species-specificity of DMT patterns
Aging and the effects of a half marathon on Achilles tendon force-elongation relationship.
PURPOSE: We aimed to determine whether there are different changes in Achilles tendon (AT) mechanical properties in middle-aged, compared to younger runners that might indicate that tendon fatigue, induced by long-distance running, is age-dependent. METHODS: 27 middle-aged (50-67 years) and 22 younger (21-29 years) participants ran a 21 km route at their own pace (mean and SD: old: 3.1 ± 0.3 m s(-1); young: 3.6 ± 0.5 m s(-1)). We tested for changes in the AT force-elongation relationship using dynamometry and ultrasonography during isometric voluntary ankle plantarflexion ramp contractions, conducted 20-28 h pre-run, immediately pre-run, immediately post-run and 20-28 h post-run. Stride frequency and number were examined to estimate cyclic tensile loading characteristics of the tendon during running. RESULTS: Muscle strength decreased significantly (P < 0.05) in both groups immediately post-run (old: 17 %; young: 11 %) and recovered to baseline within 20-28 h post-run. AT stiffness did not change for the younger adults, whereas the middle-aged adults showed a significant (P < 0.05) decrease in AT stiffness (22 %). However, tendon stiffness recovered to baseline 20-28 h post-run. Middle-aged, compared to young adults, demonstrated significantly (P < 0.05) greater stride frequency and number, but no correlations with tendon fatigue changes were determined (R (2) â€Â 0.038). CONCLUSIONS: The results suggest that the plasticity of the AT in response to short-term mechanical loading may be age dependent and that the AT length-tension properties of middle-aged runners may be more vulnerable to change following running compared to younger athletes. However, the observed AT changes in the middle-aged runners dissipated within 20-28 h post-run, suggesting that a tendon viscoelastic recovery mechanism may occur in vivo
Correlation of plasma metabolites with glucose and lipid fluxes in human insulin resistance
Objective: Insulin resistance develops prior to the onset of overt type 2 diabetes, making its early detection vital. Direct accurate evaluation is currently only possible with complex examinations like the stable isotope-based hyperinsulinemic euglycemic clamp (HIEC). Metabolomic profiling enables the detection of thousands of plasma metabolites, providing a tool to identify novel biomarkers in human obesity. Design: Liquid chromatography mass spectrometryâbased untargeted plasma metabolomics was applied in 60 participants with obesity with a large range of peripheral insulin sensitivity as determined via a two-step HIEC with stable isotopes [6,6-2H2]glucose and [1,1,2,3,3-2H5]glycerol. This additionally enabled measuring insulin-regulated lipolysis, which combined with metabolomics, to the knowledge of this research group, has not been reported on before. Results: Several plasma metabolites were identified that significantly correlated with glucose and lipid fluxes, led by plasma (gamma-glutamyl)citrulline, followed by betaine, beta-cryptoxanthin, fructosyllysine, octanylcarnitine, sphingomyelin (d18:0/18:0, d19:0/17:0) and thyroxine. Subsequent machine learning analysis showed that a panel of these metabolites derived from a number of metabolic pathways may be used to predict insulin resistance, dominated by non-essential amino acid citrulline and its metabolite gamma-glutamylcitrulline. Conclusion: This approach revealed a number of plasma metabolites that correlated reasonably well with glycemic and lipolytic flux parameters, measured using gold standard techniques. These metabolites may be used to predict the rate of glucose disposal in humans with obesity to a similar extend as HOMA, thus providing potential novel biomarkers for insulin resistance
Surgical and Hardware-Related Adverse Events of Deep Brain Stimulation:A Ten-Year Single-Center Experience
INTRODUCTION: Although deep brain stimulation (DBS) is effective for treating a number of neurological and psychiatric indications, surgical and hardware-related adverse events (AEs) can occur that affect quality of life. This study aimed to give an overview of the nature and frequency of those AEs in our center and to describe the way they were managed. Furthermore, an attempt was made at identifying possible risk factors for AEs to inform possible future preventive measures. MATERIALS AND METHODS: Patients undergoing DBS-related procedures between January 2011 and July 2020 were retrospectively analyzed to inventory AEs. The mean follow-up time was 43 ± 31 months. Univariate logistic regression analysis was used to assess the predictive value of selected demographic and clinical variables. RESULTS: From January 2011 to July 2020, 508 DBS-related procedures were performed including 201 implantations of brain electrodes in 200 patients and 307 implantable pulse generator (IPG) replacements in 142 patients. Surgical or hardware-related AEs following initial implantation affected 40 of 200 patients (20%) and resolved without permanent sequelae in all instances. The most frequent AEs were surgical site infections (SSIs) (9.95%, 20/201) and wire tethering (2.49%, 5/201), followed by hardware failure (1.99%, 4/201), skin erosion (1.0%, 2/201), pain (0.5%, 1/201), lead migration (0.52%, 2/386 electrode sites), and hematoma (0.52%, 2/386 electrode sites). The overall rate of AEs for IPG replacement was 5.6% (17/305). No surgical, ie, staged or nonstaged, electrode fixation, or patient-related risk factors were identified for SSI or wire tethering. CONCLUSIONS: Major AEs including intracranial surgery-related AEs or AEs requiring surgical removal or revision of hardware are rare. In particular, aggressive treatment is required in SSIs involving multiple sites or when Staphylococcus aureus is identified. For future benchmarking, the development of a uniform reporting system for surgical and hardware-related AEs in DBS surgery would be useful
Report from the HarmoSter study: inter-laboratory comparison of LC-MS/MS measurements of corticosterone, 11-deoxycortisol and cortisone.
Liquid chromatography-tandem mass spectrometry (LC-MS/MS) panels that include glucocorticoid-related steroids are increasingly used to characterize and diagnose adrenal cortical diseases. Limited information is currently available about reproducibility of these measurements among laboratories. The aim of the study was to compare LC-MS/MS measurements of corticosterone, 11-deoxycortisol and cortisone at eight European centers and assess the performance after unification of calibration.
Seventy-eight patient samples and commercial calibrators were measured twice by laboratory-specific procedures. Results were obtained according to in-house and external calibration. We evaluated intra-laboratory and inter-laboratory imprecision, regression and agreement against performance specifications derived from 11-deoxycortisol biological variation.
Intra-laboratory CVs ranged between 3.3 and 7.7%, 3.3 and 11.8% and 2.7 and 12.8% for corticosterone, 11-deoxycortisol and cortisone, with 1, 4 and 3 laboratories often exceeding the maximum allowable imprecision (MAI), respectively. Median inter-laboratory CVs were 10.0, 10.7 and 6.2%, with 38.5, 50.7 and 2.6% cases exceeding the MAI for corticosterone, 11-deoxycortisol and cortisone, respectively. Median laboratory bias vs. all laboratory-medians ranged from -5.6 to 12.3% for corticosterone, -14.6 to 12.4% for 11-deoxycortisol and -4.0 to 6.5% for cortisone, with few cases exceeding the total allowable error. Modest deviations were found in regression equations among most laboratories. External calibration did not improve 11-deoxycortisol and worsened corticosterone and cortisone inter-laboratory comparability.
Method imprecision was variable. Inter-laboratory performance was reasonably good. However, cases with imprecision and total error above the acceptable limits were apparent for corticosterone and 11-deoxycortisol. Variability did not depend on calibration but apparently on imprecision, accuracy and specificity of individual methods. Tools for improving selectivity and accuracy are required to improve harmonization
- âŠ