17 research outputs found

    Effect of ambient temperature on the human tear film

    Get PDF

    Protecting tear-film stability under adverse environmental conditions using a mucomimetic with a non-Newtonian viscosity agent

    Get PDF
    Background and Objectives: Tamarind-seed polysaccharide (TSP) and hyaluronic acid (HA) have mucoadhesive properties that improve drug absorption and delay in drug elimination from the ocular surface. We aimed to evaluate TSP/HA-containing formulation for its efficiency in dry-eye symptoms induced by adverse environments and the interaction between mucomimic polymer and tear-film parameters. Materials and Methods: The participants were exposed to 5% relative humidity (RH) in a Controlled Environment Chamber (CEC) under constant room temperature (21 °C). Tear-film parameters were assessed at 40% RH and 5% RH. Rohto Dry Eye Relief drops were used in the two treatment modalities, protection (drops instilled before exposure to the dry environment) and relief (drops instilled after exposure to the dry environment). The HIRCAL grid, Servomed EP3 Evaporimeter, and Keeler’s TearScope-Plus were used to screen for non-invasive tear break-up time (NITBUT), tear evaporation rate, and lipid-layer thickness (LLT) using protection and relief treatment methodology. Results: LLT was found to be significantly thinner at 5% RH compared with at 40% RH (p = 0.007). The median LLT dropped from 50–70 nm (grade 3) at 40% RH to 10–50 nm (grade 2) at 5% RH. TSP/HA eye drops significantly augment LLT in both treatment modalities, protection (p = 0.01) and relief (p = 0.004) at 5% RH. The mean evaporation rate doubled from 40.93 at 40% RH to 82.42 g/m2/h after exposure to 5% RH. In protection mode, the TSP/HA allowed the average evaporation rate to be much lower than when no TSP/HA was used at 5% RH (p &lt; 0.008). No alteration in evaporation rate was recorded when the TSP/HA drop was used after exposure (relief). The mean NITBUT was reduced from 13 s in normal conditions to 6 s in the dry environment. Instillation of TSP/HA eye drops resulted in significant improvement (p = 0.006) in tear stability, where the NITBUT increased to 8 s in both protection (before exposure) and relief (after exposure) (p = 0.001). Although improved, these values were still significantly lower than NITBUT observed at 40% RH. Conclusions: Significant protection of tear-film parameters was recorded post instillation of TSP/HA eye drop under a desiccating environment. Both treatment methods (protection and relief) were shown to be effective. The presence of TSP/HA enhances the effectiveness of teardrops in protecting the tear-film parameters when exposed to adverse environments.</p

    Analyzing the Differential Impact of Semen Preparation Methods on the Outcomes of Assisted Reproductive Techniques

    Get PDF
    Sperm separation plays a critical role in assisted reproductive technology. Based on migration, density gradient centrifugation and filtration, a properly selected sperm could help in increasing assisted reproductive outcomes in teratozoospermia (TZs). The current study aimed to assess the prognostic value of four sperm selection techniques: density gradient centrifugation (DGC), swim-up (SU), DGC-SU and DGC followed by magnetic-activated cell sorting (DGC-MACS). These were evaluated using spermatozoa functional parameters. A total of 385 infertile couples underwent the procedure of intracytoplasmic sperm injection (ICSI), with an isolated teratozoospermia in the male partner. Semen samples were prepared by using one of the mentioned sperm preparation techniques. The improvements in the percentage of normal mature spermatozoa, rate of fertilization, cleavage, pregnancy and the number of live births were assessed. The normal morphology, spermatozoa DNA fragmentation (SDF) and chromatin maturity checked by using chromomycin A3 (CMA3) with DGC-MACS preparation were better compared to the other three methods. Embryo cleavage, clinical pregnancy and implantation were better improved in the DGC-MACS than in the other tested techniques. The DGC-MACS technique helped in the selection of an increased percentage of normal viable and mature sperm with intact chromatin integrity in patients with teratozoospermia

    Synthesis, in-vitro inhibition of cyclooxygenases and in silico studies of new isoxazole derivatives

    Get PDF
    Isoxazole belongs to the class of five-membered heterocyclic compounds. The process of developing new drugs has significantly gained attention due to inadequate pharmacokinetic and safety attributes of the available drugs. This study aimed to design a new diverse array of ten novel isoxazole derivatives via Claisen Schmidt condensation reaction. In vitro COX-1/2 anti-inflammatory assay, in silico molecular docking of potent compounds, Molecular docking simulation, and SwissADME pharmacokinetic profile were investigated in this research. The in vitro COX-1 and COX-2 enzyme inhibitory assay showed that almost all the tested compounds exhibited anti-inflammatory effects whereas C6, C5, and C3 were found to be the most potent COX-2 enzyme inhibitors among the tested compounds and are good candidates for selective COX-2 inhibitors. In silico molecular docking studies coupled with molecular dynamic simulation has been done to rationalize the time-evolved mode of interaction of selected inhibitor inside the active pockets of target COX-2. The binding orientations and binding energy results also showed the selectivity of compounds towards COX-2. Physicochemical properties, pharmacokinetic profile, lipophilicity, water solubility, drug metabolism, drug-likeness properties, and medicinal chemistry of the synthesized isoxazole derivatives were assessed. The SwissADME (absorption, distribution, metabolism, and excretion) database was used to assess the physicochemical properties and drug-likeness properties of the synthesized isoxazole derivatives. All the compounds were shown high GI absorption except Compound 7 (C7). Compound 1 (C1) and Compound 2 (C2) were found to cross the blood-brain barrier (BBB). Lipinski’s rule of five is not violated by any of the ten synthesized isoxazole derivatives. It was predicted with the SwissADME database that C2, C5, C6, C7, and C8 are potent inhibitors of cytochrome (CYP) subtype CYP-2C19. A subtype of CYP-2C9 was inhibited by C4 and C7. The medicinal chemistry of all the compounds C1-C10 showed no PAIN (Pan assay interference compounds) alerts. The improved gastrointestinal (GI) absorption and BBB permeability of C1 and C2 can provide a future prospective for new researchers in the medicinal field to investigate the compounds for the management of chronic diseases. The synthesized isoxazole compounds showed excellent in vitro COX-1/2 enzymes anti-inflammatory investigations, in silico studies, good physicochemical properties, and improved pharmacokinetic profile which will be further investigated via in vivo anti-inflammatory activities. Moreover, to further support our findings of the computational research and in vitro studies, an in-vivo pharmacokinetic profile is suggested in the future

    Evaluation of different treatment modalities on the efficacy of hydroxypropyl Guar (HP-Guar) formulation on tear film stability (TFS) in subjects exposed to adverse environmental conditions

    Get PDF
    Abstract The study aimed to assess the efficacy of hydroxypropyl guar (HP) formulation (Systane) to protect tear film parameters under desiccating environment using protection and relief treatment modalities. The subjects were exposed to adverse environmental conditions using a Controlled Environment Chamber (CEC) where the relative humidity (RH) was 5% and the ambient temperature was 21 °C and screened for Tear break-up time (TBUT), Tear film evaporation rate (TFER) and lipid layer thickness (LLT) using the HIRCAL grid, Servomed EP3 Evaporimeter and Keeler’s TearScope-Plus respectively. Significant improvement in LLT was noticed in the protection modality. The mean tear film evaporation rate doubled after exposure to the humidity of 5% to a value of 105.37 g/m2/h (0.29 µl/min). All subjects displayed a significant reduction in non-invasive tear break-up time (NITBUT) with a mean NITBUT of 7.7 s after exposure to a desiccating environment for 15 min. A significant increase in NITBUT after the instillation of the drops was recorded in both methods. The results obtained from this study showed that a solution containing HP-Guar significantly improves tear film parameters under a desiccating environment. Apart from the tear evaporation rate, all tear parameters showed improvement after the use of HP-Guar eye drops. It is evident that tear film parameters respond differently to the management modalities and using CEC has the potential to provide researchers with a readily available method to evaluate the efficiency of tear supplementation

    Efficacy of hydroxypropyl-guar drops in improving tear film index and ocular surface dynamics using two treatment methods under a controlled desiccating environment

    No full text
    Aim: This study aimed to assess the efficacy of hp-guar eye drops on tear film index and ocular surface dynamics under desiccating conditions using protection and relief treatment modalities.Methodology: The 12 normal, non-dry eye participants were subjected to adverse environmental conditions using a Controlled Environment Chamber (CEC) where the relative humidity (RH) was 5% and the ambient temperature was 21 °C. The participants were screened for ocular symptoms, tear osmolarity, ocular surface temperature (OST), tear production using the Ocular Surface Disease Index questionnaire (OSDI), OcuSense TearLab Osmometer, FLIR System ThermaCAM P620, and Schirmer strips. Tear production was calculated by the Tear Function Index test (TFI).Results: The mean tear film osmolarity decreased significantly from 296 mOsm/L at 40% RH to 285 mOsm/L at 5% RH (p = 0.01). Conflicting responses were seen for osmolarity in protection and relief. Mean tear osmolarity was significantly higher in the protection method in comparison to the relief method (p = 0.005). The mean TFI increased from 557 at 40% to 854 at 5% (p = 0.02). A significant increase in TFI was observed in the relief method in comparison with both 40% (p = 0.001) and 5% (p = 0.04). In the relief method, the mean TFI score went up to 1139 when hp-guar was installed. A significant improvement in ocular comfort was experienced in both the protection (p = 0.041) and relief (p = 0.010) methods at 5% RH. The instillation of hp-guar drops in the relief method resulted in a significant reduction in OST. The mean OST dropped to 33.01 ºC, significantly lower than the recorded OST for both normal (p = 0.040) and dry (p = 0.014) environmental conditions. Conclusion: Hp-guar drops significantly improve tear film parameters under a desiccating environment, however, tear film parameters respond differently to the management modalities. In the protection method, tear film osmolarity was protected against a dry environment, while in the relief mode, an improvement in tear production and a decrease in ocular surface temperature were seen. Hp-guar performance could be maximized for the management of exposure to adverse environments by using a treatment protocol that targets the most affected parameters in each group of patients. Using CEC has the potential to provide researchers with a readily available method to evaluate the efficiency of tear supplementation.</p

    Accommodative Response in Patients with Central Field Loss: A Matched Case-Control Study

    No full text
    Purpose: This study was conducted to evaluate the accommodative response in young participants with visual impairment in comparison with visually normal participants. Methods: Fifteen participants with confirmed visual impairment and 30 visually normal participants aged 12–15 years were recruited. Accommodative response was measured using autorefractor (Grand Seiko WV500) at distances of accommodative demand of 33, 25, and 20 cm. The targets were one-line-above participant threshold acuity. The participants’ accommodative responses were compared between both groups after calibration for refractive errors and the vertex distance of the glasses. Visual acuity and refractive status were also assessed. Results: The age was not significantly different between both participant groups. The visual acuity of visually impaired patients was 6/30 to 6/240, and that of visually normal participants was 6/7.5 or better. Ten of the visually impaired patients and 29 of visually normal participants were myopic. In total, 61–73% of visually impaired patients showed an accommodative lead. Five subtypes of accommodative response were observed. In general, the accommodative inaccuracy increased with increasing accommodative demand. However, the visually normal participants largely exhibited an accommodative lag. A mild-to-moderate relationship was observed between visual acuity and accommodative response (r = 0.3–0.5, p &lt; 0.05). Conclusion: Accommodative response in young visually impaired patients can be variable and on an individual basis. Low vision specialists should anticipate accommodative response outside the normal range. Therefore, we shall consider evaluating each patient’s accommodative response before prescribing any near addition lenses. Accommodation inaccuracy is often more complex than predicted due to increased depth of focus caused by reduced visual acuity

    Analyzing the Differential Impact of Semen Preparation Methods on the Outcomes of Assisted Reproductive Techniques

    Get PDF
    Sperm separation plays a critical role in assisted reproductive technology. Based on migration, density gradient centrifugation and filtration, a properly selected sperm could help in increasing assisted reproductive outcomes in teratozoospermia (TZs). The current study aimed to assess the prognostic value of four sperm selection techniques: density gradient centrifugation (DGC), swim-up (SU), DGC-SU and DGC followed by magnetic-activated cell sorting (DGC-MACS). These were evaluated using spermatozoa functional parameters. A total of 385 infertile couples underwent the procedure of intracytoplasmic sperm injection (ICSI), with an isolated teratozoospermia in the male partner. Semen samples were prepared by using one of the mentioned sperm preparation techniques. The improvements in the percentage of normal mature spermatozoa, rate of fertilization, cleavage, pregnancy and the number of live births were assessed. The normal morphology, spermatozoa DNA fragmentation (SDF) and chromatin maturity checked by using chromomycin A3 (CMA3) with DGC-MACS preparation were better compared to the other three methods. Embryo cleavage, clinical pregnancy and implantation were better improved in the DGC-MACS than in the other tested techniques. The DGC-MACS technique helped in the selection of an increased percentage of normal viable and mature sperm with intact chromatin integrity in patients with teratozoospermia

    In Silico, SwissADME, and DFT Studies of Newly Synthesized Oxindole Derivatives Followed by Antioxidant Studies

    No full text
    The compounds were synthesized by refluxing 6-chlorooxindole with 2,3-dichlorobenzaldehyde and 2,6-dichlorobenzaldehyde in the presence of piperidine as a catalyst and characterized by spectroscopic analysis using 1H NMR, 13C NMR, and mass spectrometry as (E)-3-(2,3-dichlorobenzylidene)-6-chloroindolin-2-one (C-1) and (E)-3-(2,6-dichlorobenzylidene)-6-chloroindolin-2-one (C-2). Additionally, in silico ADME studies indicated that C-1 and C-2 with 1,1 rotatable bonds could have moderate water solubility and therefore could have the potential ability to cross the blood-brain barrier. Both showed high GI absorption, indicating that they are suitable for intestinal absorption while the compounds showed CYP1A2, CYP2C19, and CYP2C9 inhibition. The five drug-likeness criteria, which were Lipinski, Muegge, Ghose, Veber, and Egan, and the principles of drug-likeness are not violated by compounds C-1 and C-2. Also, the DFT computations were performed at the B3LYP level and at 6-311++G∗∗ basis set to evaluate and support the obtained results from the experiment. The FMO results revealed that C-1 could likely prefer the intramolecular interactions rather than the intermolecular interactions, and vice versa for C-2. In addition, the NBO results indicated that the resonance interaction, especially the shift of electron to empty orbitals from lone pair electrons of nitrogen, would contribute to the stabilization of both compounds greatly. In DPPH assay, the compounds showed IC50 values of 37.390 and 34.676 μM, respectively. Similarly, in ABTS assay, the calculated IC50 values for the compounds were 25.381 and 33.706 μM, respectively. In short, these results provided a solid ground for further preclinical studies in quest of new effective therapeutic agents
    corecore