96 research outputs found
Seasonal adjustment of daily data with CAMPLET
In the last decade large data sets have become available, both in terms of the number of time series and with higher frequencies (weekly, daily and even higher). All series may suffer from seasonality, which hides other important fluctuations. Therefore time series are typically seasonally adjusted. However, standard seasonal adjustment methods cannot handle series with higher than monthly frequencies. Recently, Abeln et al. (2019) presented CAMPLET, a new seasonal adjustment method, which does not produce revisions when new observations become available. The aim of this paper is to show the attractiveness of CAMPLET for seasonal adjustment of daily time series. We apply CAMPLET to daily data on the gas system in the Netherlands
The Ross procedure versus repair for treatment of a unicuspid aortic valve in adults
OBJECTIVES
Aortic stenosis or regurgitation in patients with a unicuspid valve morphology requires interventions early in life. We have performed either primary valve repair or the Ross procedure. The goal of this study was to compare the midterm results of repair and pulmonary autograft replacement.
METHODS
Between December 1998 and April 2022, a total of 345 patients (77% male; mean age 34 ± 9.7 years) underwent treatment of a unicuspid aortic valve. Patients were excluded if they were 54 years (n = 3) at the time of the operation. The remaining cohort was divided into 2 groups: 167 (64%) patients underwent valve repair; 91 (36%) patients underwent pulmonary autograft replacement.
The indications for surgery were aortic regurgitation (n = 104), aortic stenosis (n = 45), combined disease (n = 103) and endocarditis (n = 6). Fifty-one patients had root dilatation (>43 mm) with aortic regurgitation (repair n = 23; Ross n = 28). Mean follow-up was 5.9 years (SD: 5 years) [range 0.1–22.3 years].
RESULTS
There were 1 early and 3 late deaths; 47 patients required reintervention. Survival at 10 years was 95% in the Ross group and 97% after valve repair (P = 0.769). Freedom from reintervention at 10 years was 98% in the Ross group and 80% after valve repair (P = 0.012). A receiver operating characteristics curve analysis showed a trend towards better durability in patients < 26 years.
CONCLUSIONS
The ideal treatment of the unicuspid aortic valve remains debatable. Repair of a unicuspid valve can be considered a bridge to pulmonary autograft replacement, at least in younger patients. The appropriate times to replace and to repair require further investigation
Autograft reoperations after the Ross procedure
OBJECTIVES: After a Ross procedure, autograft failure can occur. At reoperation, repair of the autograft preserves the advantages of the
Ross procedure. The aim of this retrospective study was to assess mid-term results after reoperation of a failed autograft.
METHODS: Between 1997 and 2022, 30 consecutive patients (83% male; age 41 ± 11 years) underwent autograft reintervention between
60 days and 24 years (median 10 years) after a Ross procedure. The initial technique varied, full-root replacement (n = 25) being the most
frequent. The indication for reoperation was isolated autograft regurgitation (n = 7), root dilatation (>43 mm) with (n = 17) or without
(n = 2) autograft regurgitation, mixed dysfunction (n = 2) and endocarditis (n = 2). In 4 instances, the valve was replaced by valve (n = 1) or
combined valve and root replacement (n = 3). Valve-sparing procedures consisted of isolated valve repair (n = 7) or root replacement
(n = 19), and tubular aortic replacement. Cusp repair was performed in all but 2. Mean follow-up was 5.4 ± 6 years (35 days to 24 years).
RESULTS: Mean cross-clamp and perfusion times were 74 ± 26 and 132 ± 64 min. There were 2 perioperative deaths (7%; both valve replacement) and 2 patients died late (32 days to 1.2 years postoperatively). Freedom from cardiac death at 10 years was 96% after valve repair and 50% after replacement. Two patients required reoperation (1.68 and 16 years) following repair. One underwent valve replacement for cusp perforation, the other, root remodelling for dilatation. Freedom from autograft reintervention at 15 years was 95%.
CONCLUSIONS: Autograft reoperations after the Ross procedure can be performed as valve-sparing operations in the majority of cases.
With valve-sparing, long-term survival and freedom from reoperation are excellent
Which Aortic Valve Can Be Surgically Reconstructed?
Purpose of Review
Preservation or repair of the aortic valve has evolved dynamically in the past 20 years. It leads to a high freedom from valve-related complications if an adequate valve durability can be achieved; it may possibly also improve survival. To date, little structured information is available about which valves can be repaired and which should better be replaced.
Recent Findings
For surgical decision-making, the size of the aortic root is important and the anatomy of the aortic valve must be considered. In the presence of root aneurysm, most tricuspid and bicuspid aortic valves can be preserved. In aortic regurgitation and normal aortic dimensions, the majority of tricuspid and bicuspid aortic valves can be repaired with good long-term durability. In bicuspid aortic valves, the morphologic characteristics must be taken into consideration. Unicuspid and quadricuspid aortic valves can be repaired in selected cases. Generally, cusp calcification is a sign of a poor substrate for repair; the same is true for cusp retraction and cusp destruction due to active endocarditis. They are associated with limited valve durability.
Summary
Using current concepts, many non-calcified aortic valves can be repaired. Modern imaging, in particular three-dimensional transesophageal echocardiography (TEE), should be able to define repairable aortic valves with a high probability
Experimental ionization of atomic hydrogen with few-cycle pulses
We present the first experimental data on strong-field ionization of atomic
hydrogen by few-cycle laser pulses. We obtain quantitative agreement at the 10%
level between the data and an {\it ab initio} simulation over a wide range of
laser intensities and electron energies
- …