3 research outputs found

    The recent development of protection coordination schemes based on inverse of AC microgrid: A review

    Get PDF
    Integration of distributed generation systems and diversity of microgrid operations led to a change in the structure of the power system. Due to this conversion, new challenges have arisen when employing traditional overcurrent protection schemes. As a consequence, non‐classical protection schemes have attracted significant attention in the last few years. Engineers and scholars have proposed different non‐standard methods to increase the power protection system and ensure the highly selectivity performance. Although the non‐standard characteristics and their requirements, in general, have been outlined and analyzed in the available literature, protection coordination based on voltage current–time inverse, as a branch of non‐standard optimization methods, has not yet been thoroughly discussed, compared, or debated in detail. To close this gap, this review introduces a broad overview of recent research and developments of the voltage current–time inverse based protection coordination. Focuses on assessing the potential advantages and disadvantages of related studies and provide a classification and analysis of these studies. The future trends and some recommendations have been included in this review for improving fault detection sensitivity and coordination reliability

    Innovative Optimal Nonstandard Tripping Protection Scheme for Radial and Meshed Microgrid Systems

    No full text
    The coordination of optimal overcurrent relays (OCRs) for modern power networks is nowadays one of the critical concerns due to the increase in the use of renewable energy sources. Modern grids connected to inverter-based distributed generations (IDGs) and synchronous distributed generations (SDGs) have a direct impact on fault currents and locations and then on the protection system. In this paper, a new optimal OCR coordination scheme has been developed based on the nonstandard time–current characteristics (NSTCC) approach. The proposed scheme can effectively minimize the impact of distributed generations (DGs) on OCR coordination by using two optimization techniques: genetic algorithm (GA) and hybrid gravitational search algorithm–sequential quadratic programming (GSA–SQP) algorithm. In addition, the proposed optimal OCR coordination scheme has successfully employed a new constraint reduction method for eliminating the considerable number of constraints in the coordination and tripping time formula by using only one variable dynamic coefficient. The proposed protection scheme has been applied in IEEE 9-bus and IEC MG systems as benchmark radial networks as well as IEEE 30-bus systems as meshed structures. The results of the proposed optimal OCR coordination scheme have been compared to standard and nonstandard characteristics reported in the literature. The results showed a significant improvement in terms of the protection system sensitivity and reliability by minimizing the operating time (OT) of OCRs and demonstrating the effectiveness of the proposed method throughout minimum and maximum fault modes

    The recent development of protection coordination schemes based on inverse of AC microgrid: A review

    No full text
    Integration of distributed generation systems and diversity of microgrid operations led to a change in the structure of the power system. Due to this conversion, new challenges have arisen when employing traditional overcurrent protection schemes. As a consequence, non‐classical protection schemes have attracted significant attention in the last few years. Engineers and scholars have proposed different non‐standard methods to increase the power protection system and ensure the highly selectivity performance. Although the non‐standard characteristics and their requirements, in general, have been outlined and analyzed in the available literature, protection coordination based on voltage current–time inverse, as a branch of non‐standard optimization methods, has not yet been thoroughly discussed, compared, or debated in detail. To close this gap, this review introduces a broad overview of recent research and developments of the voltage current–time inverse based protection coordination. Focuses on assessing the potential advantages and disadvantages of related studies and provide a classification and analysis of these studies. The future trends and some recommendations have been included in this review for improving fault detection sensitivity and coordination reliability
    corecore