3 research outputs found

    Hydrogeophysical Investigation in Parts of the Eastern Dahomey Basin, Southwestern Nigeria: Implications for Sustainable Groundwater Resources Development and Management

    No full text
    Geoelectrical resistivity measurements were conducted in five locations within the eastern portion of the Dahomey basin for the purpose of subsurface evaluation and detecting saturated zones. The locations are Covenant University (L1), Bells University (L2), Oju-Ore-Ilogbo Road (L3), Obasanjo-Ijagba Road (L4), and Iyana Iyesi (L5). The study was carried out to avert the common challenges of drilling low-yield groundwater boreholes in the area. A total of 30 Vertical Electrical Soundings (VES) and five two-dimensional Electrical Resistivity Tomography (ERT) data sets have been acquired along the study areas. The geoelectrical resistivity results were integrated with the borehole logs to generate the spatial distribution of the subsurface lithologies in the area. The delineated subsurface lithologies include the topsoil (lateritic clay), clayey sand, sandy clay, fine silty sand, coarse sand, and shale/clay units. The fine silty sand and coarse sand units were identified as the two main aquifer units within the area. The depths to the upper aquifer unit in the area include 31.7–96.7 m, 38.5–94.0 m, 30.7–57.5 m, 39.1–63.4 m, and 46.9–57.5 m for locations L1, L2, L3, L4, and L5, respectively. At the same time, the depths to the lower aquifer unit in the area include 43.4–112.7 m, 52.2–108.0 m, 44.2–72.5 m, 53.7–78.5 m, and 63.5–72.9 m for locations L1, L2, L3, L4, and L5, respectively. The estimated hydraulic parameters for both aquifers show they are highly productive with mean porosity, mean hydraulic conductivity, and mean transmissivity of 20–22%, 12.4–17.0 Γ— 10βˆ’2 m/s, 1.56–2.18 m2/s for the upper aquifer, and 48–50%, 371–478 Γ— 10βˆ’2 m/s, 50.00–62.14 m2/s for the lower aquifer. By focusing on these aquifer systems during exploration, sustainable groundwater resources can be secured, providing relief to homeowners within the study area who might otherwise face the frustration of drilling unproductive and low-yield boreholes. However, it is crucial to consider the presence of sub-vertical faults in the study area, as these faults can significantly impact groundwater development and management. These sub-vertical structural faults may lead to changes in the permeability, hydraulic conductivity, and transmissivity of the delineated aquifers, affecting their productivity across the divide and ultimately influencing the overall water availability in the area. Careful consideration of these geological factors is essential for effective aquifer management and sustainable groundwater utilisation

    Geoelectrical Characterization of Coastal Aquifers in Agbado-Ijaye, Lagos, Southwestern Nigeria; Implications for Groundwater Resources Sustainability

    Get PDF
    Water is a natural resource; its availability depends on climatic and geological conditions, and it is invariably controlled by human activities. Agbado-Ijaye lies within a coastal area, where local communities have been facing incessant water shortages, especially during the dry season. This study investigated the groundwater-bearing geological unit(s) using hydrogeophysical techniques in the coastal environment. The electrical resistivity technique, involving vertical electrical sounding (VES) and two-dimensional (2D) electrical resistivity imaging via Wenner array electrode configuration, was used to characterize the geoelectric distribution. Twenty VES stations were investigated and current electrodes (AB/2 m) spacing expanded from 1–200 m; four 2D electrical resistivity imaging traverses having a length of 200 m each and interelectrode spacing of 10 m (level 1) to 60 m (level 6) was adopted. Four geoelectric units were delineated, namely: topsoil (15–251 Ωm), clayey (28–100 Ωm), clayey sand (125–190 Ωm) and sandy (205–876 Ωm) with thicknesses ranging from 0.7–1.3 m, 4.1–19.0 m, 2.6–15.6 m and undefined depth, respectively. The 2D imaging sections also detected similar geoelectric layers, corroborating the VES-derived sections. The inverted sections delineated two different aquifers: the shallower low-yield aquifer comprising sandy clay/clayey sand units with a maximum depth of about 5.5 m. This layer is adjudged to be the continental plain sand of the Benin Formation. The deeper high-yield aquifer with a maximum depth of 30.4 m is a beach sand unit that belongs to the Tertiary Alluvium of the Dahomey Basin. The study showed that hydrogeophysical investigation is vital in exploring, developing, and managing coastal groundwater resources
    corecore