579 research outputs found

    Trial protocol OPPTIMUM : does progesterone prophylaxis for the prevention of preterm labour improve outcome?

    Get PDF
    Background Preterm birth is a global problem, with a prevalence of 8 to 12% depending on location. Several large trials and systematic reviews have shown progestogens to be effective in preventing or delaying preterm birth in selected high risk women with a singleton pregnancy (including those with a short cervix or previous preterm birth). Although an improvement in short term neonatal outcomes has been shown in some trials these have not consistently been confirmed in meta-analyses. Additionally data on longer term outcomes is limited to a single trial where no difference in outcomes was demonstrated at four years of age of the child, despite those in the “progesterone” group having a lower incidence of preterm birth. Methods/Design The OPPTIMUM study is a double blind randomized placebo controlled trial to determine whether progesterone prophylaxis to prevent preterm birth has long term neonatal or infant benefit. Specifically it will study whether, in women with singleton pregnancy and at high risk of preterm labour, prophylactic vaginal natural progesterone, 200 mg daily from 22 – 34 weeks gestation, compared to placebo, improves obstetric outcome by lengthening pregnancy thus reducing the incidence of preterm delivery (before 34 weeks), improves neonatal outcome by reducing a composite of death and major morbidity, and leads to improved childhood cognitive and neurosensory outcomes at two years of age. Recruitment began in 2009 and is scheduled to close in Spring 2013. As of May 2012, over 800 women had been randomized in 60 sites. Discussion OPPTIMUM will provide further evidence on the effectiveness of vaginal progesterone for prevention of preterm birth and improvement of neonatal outcomes in selected groups of women with singleton pregnancy at high risk of preterm birth. Additionally it will determine whether any reduction in the incidence of preterm birth is accompanied by improved childhood outcome

    Automatic Detection and Classification of Breast Tumors in Ultrasonic Images Using Texture and Morphological Features

    Get PDF
    Due to severe presence of speckle noise, poor image contrast and irregular lesion shape, it is challenging to build a fully automatic detection and classification system for breast ultrasonic images. In this paper, a novel and effective computer-aided method including generation of a region of interest (ROI), segmentation and classification of breast tumor is proposed without any manual intervention. By incorporating local features of texture and position, a ROI is firstly detected using a self-organizing map neural network. Then a modified Normalized Cut approach considering the weighted neighborhood gray values is proposed to partition the ROI into clusters and get the initial boundary. In addition, a regional-fitting active contour model is used to adjust the few inaccurate initial boundaries for the final segmentation. Finally, three textures and five morphologic features are extracted from each breast tumor; whereby a highly efficient Affinity Propagation clustering is used to fulfill the malignancy and benign classification for an existing database without any training process. The proposed system is validated by 132 cases (67 benignancies and 65 malignancies) with its performance compared to traditional methods such as level set segmentation, artificial neural network classifiers, and so forth. Experiment results show that the proposed system, which needs no training procedure or manual interference, performs best in detection and classification of ultrasonic breast tumors, while having the lowest computation complexity

    Assessment of 1183 screen-detected, category 3B, circumscribed masses by cytology and core biopsy with long-term follow up data

    Get PDF
    Discrete masses are commonly detected during mammographic screening and most such lesions are benign. For lesions without pathognomonically benign imaging features that are still regarded likely to be non-malignant (Tabar grade 3) reliable biopsy results would be a clinically useful alternative to mammographic surveillance. Appropriate institutional guidelines for ethical research were followed. Between Jan 1996–Dec 2005 grade 3B discrete masses detected in the setting of a large, population based, breast cancer screening programme are included. Patient demographics, fine needle aspiration biopsy (FNAB), core and surgical biopsy results are tabulated. The final pathology of excised lesions was obtained. Information regarding interval cancers was obtained from the State Cancer Registry records and also through long term follow-up of clients in subsequent rounds of screening. A total of 1183 lesions, mean diameter of 13.3 mm (±8.3 mm) and mean client age of 55.1 years (±8.8 years) are included. After diagnostic work up, 98 lesions (8.3%) were malignant, 1083 were non-malignant and a final histologic diagnosis was not established in two lesions. In the 27 months after assessment, no interval cancers were attributable to these lesions and during a mean follow up of 54.5 months, available in 84.9% of eligible women, only one cancer has developed in the same quadrant as the original lesion, although the two processes are believed to be unrelated. FNAB performed in 1149 cases was definitive in 80.5% cases (882 benign, 43 malignant) with a negative predictive value (NPV) of 99.8% (880 of 882) and a positive predictive value (PPV) of 95.2% (40 of 42, both intraductal papillomas). Core biopsy was performed in 178 lesions, mostly for indefinite cytology. Core biopsy was definitive in 79.8% cases (57% benign 22% malignant) with a PPV of 100% and NPV of 99.0%. In experienced hands FNAB is an accurate first line diagnostic modality for the assessment of 3B screen-detected discrete masses, providing definitive results in 80.5% of cases. When used as a second line modality, core biopsy had a similarly high rate of definitive diagnosis at 79.8%. The stepwise approach to the use of FNAB and core biopsy would reduce substantially the proportion of cases requiring surgical diagnostic biopsy. Given the low probability of malignancy and the imperative to limit the morbidity associated with cancer screening, the demonstration of the reliability of FNAB as a minimally invasive but highly accurate test for this particular subset of screen-detected lesions has significant clinical utility

    Ultrasound-guided large-core needle biopsies of breast lesions: analysis of 962 cases to determine the number of samples for reliable tumour classification

    Get PDF
    The objective of this one-institutional study was to determine the number of large-core needle biopsies (LCNB), under three-dimensional ultrasound (3D-US) validation, that are sufficient to obtain a reliable histological diagnosis of a sonographically detectable breast lesion. Over an 28-month period, 962 sonographically guided LCNB were performed under 3D-US validation to assess 962 breast lesions. All biopsies were carried out with an automated core biopsy device fitted with 14-gauge (22 mm excursion) needles. Data of 962 biopsied breast lesions were gathered. Surgical follow-up was available for 659 lesions. Breast malignancies were diagnosed by ultrasound-guided LCNB with a sensitivity of 98.2% by performing three cores per lesion. In few cases, the open surgical specimen revealed the presence of invasive carcinomas in contrast to initial LNCB-based classification as ductal carcinomas in situ (DCIS, 11 lesions), lobular carcinoma in situ (one lesion), and atypical ductal hyperpasia (one lesion). Owing to disagreement between classification based on breast-imaging and histological findings, eight of these tumours were subsequently excised. Of the lesions that were removed at the patients' requests despite benign LCNB diagnosis, two were infiltrating carcinoma and one a DCIS. We demonstrate that three 3D-US-guided percutaneous core specimens are sufficient to achieve tissue for a reliable histological assessment of sonographically detectable breast lesions and allow the detection of malignancies with high sensitivity and low rate of false-negative diagnoses

    A comparison of Power Doppler with conventional sonographic imaging for the evaluation of renal artery stenosis

    Get PDF
    BACKGROUND: Power Doppler (PD) has improved diagnostic capabilities of vascular sonography, mainly because it is independent from the angle of insonation. We evaluated this technique in a prospective comparison with conventional imaging, consisting in Duplex and Color Doppler, for the evaluation of Renal Artery (RA) stenosis. METHODS: Sensitivity, specificity and predictive values of PD and conventional imaging were assessed in a blinded fashion on eighteen patients, 9 with angiographic evidence of unilateral RA stenosis (hypertensive patients) and 9 with angiographically normal arteries (control group). PD images were interpreted with an angiography-like criteria. RESULTS: In the control group both techniques allowed correct visualization of 16 out of the 18 normal arteries (93% specificity). Only in five hypertensive patients RA stenosis was correctly identified with conventional technique (56% sensitivity and 86% negative predictive value); PD was successful in all hypertensive patients (100% sensitivity and negative predictive value), since the operators could obtain in each case of RA stenosis a sharp color signal of the whole vessel with a clear "minus" at the point of narrowing of the lumen. All results were statistically significant (p < 0.01). CONCLUSIONS: This study demonstrates that PD is superior to conventional imaging, in terms of sensitivity and specificity, for the diagnosis of RA stenosis, because it allows a clear visualization of the whole stenotic vascular lumen. Especially if it is used in concert with the other sonographic techniques, PD can enable a more accurate imaging of renovascular disease with results that seem comparable to selective angiography

    Diagnostic role of new Doppler index in assessment of renal artery stenosis

    Get PDF
    BACKGROUND: Renal artery stenosis (RAS) is one of the main causes of secondary systemic arterial hypertension. Several non-invasive diagnostic methods for RAS have been used in hypertensive patients, such as color Doppler ultrasound (US). The aim of this study was to assess the sensitivity and specificity of a new renal Doppler US direct-method parameter: the renal-renal ratio (RRR), and compare with the sensitivity and specificity of direct-method conventional parameters: renal peak systolic velocity (RPSV) and renal aortic ratio (RAR), for the diagnosis of severe RAS. METHODS: Our study group included 34 patients with severe arterial hypertension (21 males and 13 females), mean age 54 (± 8.92) years old consecutively evaluated by renal color Doppler ultrasound (US) for significant RAS diagnosis. All of them underwent digital subtraction arteriography (DSA). RAS was significant if a diameter reduction > 50% was found. The parameters measured were: RPSV, RAR and RRR. The RRR was defined as the ratio between RPSV at the proximal or mid segment of the renal artery and RPSV measured at the distal segment of the renal artery. The sensitivity and specificity cutoff for the new RRR was calculated and compared with the sensitivity and specificity of RPSV and RAR. RESULTS: The accuracy of the direct method parameters for significant RAS were: RPSV >200 cm/s with 97% sensitivity, 72% specificity, 81% positive predictive value and 95% negative predictive value; RAR >3 with 77% sensitivity, 90% specificity, 90% positive predictive value and 76% negative predictive value. The optimal sensitivity and specificity cutoff for the new RRR was >2.7 with 97% sensitivity (p < 0.004) and 96% specificity (p < 0.02), with 97% positive predictive value and 97% negative predictive value. CONCLUSION: The new RRR has improved specificity compared with the direct method conventional parameters (RPSV >200cm/s and RAR >3). Both RRR and RPSV show better sensitivity than RAR for the RAS diagnosis

    Value of tissue harmonic imaging (THI) and contrast harmonic imaging (CHI) in detection and characterisation of breast tumours

    Get PDF
    The purpose of this study was to investigate the extent to which tissue harmonic imaging (THI), speckle reduction imaging (SRI), spatial compounding (SC) and contrast can improve detection and differentiation of breast tumours. We examined 38 patients (14 benign, 24 malignant tumours) with different combinations of THI, SRI and SC. The effect on delineation, margin, tissue differentiation and posttumoral phenomena was evaluated with a three-point score. Additionally, 1oo not palpable tumours (diameters: 4–15 mm) were examined by contrast harmonic imaging (CHI) with power Doppler. After bolus injection (0.5 ml Optison), vascularisation and enhancement were observed for 20 min. The best combination for detection of margin, infiltration, echo pattern and posterior lesion boundary was the combination of SRI level 2 with SC low. THI was helpful for lesions OF more than 1 cm depth. In native Power Doppler, vessels were found in 54 of 100 lesions. Within 5 min after contrast medium (CM) injection, marginal and penetrating vessels increased in benign and malignant tumours and central vessels mostly in carcinomas (p<0.05). A diffuse CM accumulation was observed up to 20 min after injection in malignant tumours only (p<0.05). THI, SRI and SC improved delineation and tissue differentiation. Second-generation contrast agent allowed detection of tumour vascularisation with prolonged enhancement
    corecore