    Endocytic cargo such as the transferrin receptor is incorporated into clathrin-coated pits by associating, via tyrosine-based motifs, with the AP2 complex. Cargo-AP2 interactions occur via the mu2 subunit of AP2, which needs to be phosphorylated for endocytosis to occur. The most likely role for mu2 phosphorylation is in cargo recruitment because mu2 phosphorylation enhances its binding to internalization motifs. Here, we investigate the control of mu2 phosphorylation. We identify clathrin as a specific activator of the mu2 kinase and, in permeabilized cells, we show that ligand sequestration, driven by exogenous clathrin, results in elevated levels of mu2 phosphorylation. Furthermore, we show that AP2 containing phospho-mu2 is mainly associated with assembled clathrin in vivo, and that the level of phospho-mu2 is strongly reduced in a chicken B cell line depleted of clathrin heavy chain. Our results imply a central role for clathrin in the regulation of cargo selection via the modulation of phospho-mu2 levels

    Gonad shielding in paediatric pelvic radiography: disadvantages prevail over benefit

    Get PDF
    Objective To re-evaluate gonad shielding in paediatric pelvic radiography in terms of attainable radiation risk reduction and associated loss of diagnostic information. Methods A study on patient dose and the quality of gonad shielding was performed retrospectively using 500 pelvic radiographs of children from 0 to 15 years old. In a subsequent study, 195 radiographs without gonad shielding were included. Patient doses and detriment adjusted risks for heritable disease and cancer were calculated with and without gonad shielding. Results For girls, gonad shields were placed incorrectly in 91% of the radiographs; for boys, in 66%. Without gonad shielding, the hereditary detriment adjusted risk for girls ranged between 0.1?×?10?6 and 1.3?×?10?6 and for boys between 0.3?×?10?6 and 3.9?×?10?6, dependent on age. With shielding, the reduction in hereditary risk for girls was on average 6?±?3% of the total risk of the radiograph, for boys 24?±?6%. Without gonad shielding, the effective dose ranged from 0.008 to 0.098 mSv. Conclusions With modern optimised X-ray systems, the reduction of the detriment adjusted risk by gonad shielding is negligibly small. Given the potential consequences of loss of diagnostic information, of retakes, and of shielding of automatic exposure-control chambers, gonad shielding might better be discontinued.Support TNWApplied Science

    Pediatric interventional radiography equipment: safety considerations

    Get PDF
    This paper discusses pediatric image quality and radiation dose considerations in state-of-the-art fluoroscopic imaging equipment. Although most fluoroscopes are capable of automatically providing good image quality on infants, toddlers, and small children, excessive radiation dose levels can result from design deficiencies of the imaging device or inappropriate configuration of the equipment’s capabilities when imaging small body parts. Important design features and setup choices at installation and during the clinical use of the imaging device can improve image quality and reduce radiation exposure levels in pediatric patients. Pediatric radiologists and cardiologists, with the help of medical physicists, need to understand the issues involved in creating good image quality at reasonable pediatric patient doses. The control of radiographic technique factors by the generator of the imaging device must provide a large dynamic range of mAs values per exposure pulse during both fluoroscopy and image recording as a function of patient girth, which is the thickness of the patient in the posterior–anterior projection at the umbilicus (less than 10 cm to greater than 30 cm). The range of pulse widths must be limited to less than 10 ms in children to properly freeze patient motion. Variable rate pulsed fluoroscopy can be leveraged to reduce radiation dose to the patient and improve image quality. Three focal spots with nominal sizes of 0.3 mm to 1 mm are necessary on the pediatric unit. A second, lateral imaging plane might be necessary because of the child’s limited tolerance of contrast medium. Spectral and spatial beam shaping can improve image quality while reducing the radiation dose. Finally, the level of entrance exposure to the image receptor of the fluoroscope as a function of operator choices, of added filter thickness, of selected pulse rate, of the selected field-of-view and of the patient girth all must be addressed at installation

    Reduced atrial connexin43 expression after pediatric heart surgery

    No full text
    Myocardial dysfunction and arrhythmias may be induced by congenital heart defects, but also be the result of heart surgery with cardiopulmonary bypass (CPB), potentially caused by differential expression of connexin40 (Cx40) and connexin43 (Cx43). In 16 pediatric patients undergoing corrective heart surgery, connexin mRNA expression was studied in volume overloaded (VO group, n=8) and not overloaded (NO group, n=8) right atrial myocardium, excised before and after CPB. Additionally, in eight of these patients ventricular specimens were investigated. The atrial Cx43 expression decreased during CPB, which was restricted to the VO group (p=0.008). In contrast, atrial Cx40 mRNA did not change during CPB. In ventricular myocardium compared to atrial mRNA levels, Cx40 was lower (p=0.006) and Cx43 higher (p=0.017) expressed, without significant change during CPB. This study revealed a significant influence of CPB and the underlying heart defect on Cx43 expression
    corecore