42 research outputs found

    Reproducibility of volumetric intravascular ultrasound radiofrequency-based analysis of coronary plaque composition in vivo

    Get PDF
    Intravascular ultrasound radiofrequency (RF-IVUS) data permit the analysis of coronary plaque composition in vivo and is used as an endpoint of ongoing pharmacological intervention trials. We assessed the reproducibility of volumetric RF-IVUS analyses in mild-to-moderately diseased atherosclerotic human coronary arteries in vivo. A total of 9,212 IVUS analyses on cross-sectional IVUS frames was performed to evaluate the reproducibility of volumetric RF-IVUS measurements in 33 coronary segments with a length of 27 ± 7 mm. For vessel, lumen, and plaque + media volume the relative measurement differences (P = NS for all) were (A = intraobserver comparison, same pullback) −0.40 ± 1.0%; −0.48 ± 1.4%; −0.35 ± 1.6%, (B = intraobserver comparison, repeated pullback) −0.42 ± 1.2%; −0.52 ± 1.8%; −0.43 ± 4.5% (C = interobserver comparison, same pullback) 0.71 ± 1.8%; 0.71 ± 2.2%, and 0.89 ± 5.0%, respectively. For fibrous, fibro-lipidic, calcium, and necrotic-core volumes the relative measurement differences (P = NS for all) were (A) 0.45 ± 2.1%; −1.12 ± 4.9%; −0.84 ± 2.1%; −0.22 ± 1.8%, (B) 1.40 ± 4.1%; 1.26 ± 6.7%; 2.66 ± 7.4%; 0.85 ± 4.4%, and (C) −1.60 ± 4.9%; 3.85 ± 8.2%; 1.66 ± 7.5%, and −1.58 ± 4.7%, respectively. Of note, necrotic-core volume showed on average the lowest measurement variability. Thus, in mild-to-moderate atherosclerotic coronary artery disease the reproducibility of volumetric compositional RF-IVUS measurements from the same pullback is relatively high, but lower than the reproducibility of geometrical IVUS measurements. Measurements from repeated pullbacks and by different observers show acceptable reproducibilities; the volumetric measurement of the necrotic-core shows on average the highest reproducibility of the compositional RF-IVUS measurement

    Impact of analyzing less image frames per segment for radiofrequency-based volumetric intravascular ultrasound measurements in mild-to-moderate coronary atherosclerosis

    Get PDF
    Volumetric radiofrequency-based intravascular ultrasound (RF–IVUS) data of coronary segments are increasingly used as endpoints in serial trials of novel anti-atherosclerotic therapies. In a relatively time-consuming process, vessel and lumen contours are defined; these contours are first automatically detected, then visually checked, and finally (in most cases) manually edited to generate reliable volumetric data of vessel geometry and plaque composition. Reduction in number of cross-sectional images for volumetric analysis could save analysis time but may also increase measurement variability of volumetric data. To assess whether a 50% reduction in number of frames per segment (every second frame) alters the reproducibility of volumetric measurements, we performed repeated RF–IVUS analyses of 15 coronary segments with mild-to-moderate atherosclerosis (20.2 ± 0.2 mm-long segments with 46 ± 13% plaque burden). Volumes were calculated based on a total of 731 image frames. Reducing the number of cross-sectional image frames for volumetric measurements saved analysis time (38 ± 9 vs. 68 ± 17 min/segment; P < 0.0001) and resulted for only a few parameters in (borderline) significant but mild differences versus measurements based on all frames (fibrous volume, P < 0.05; necrotic-core volume, P = 0.07). Compared to the intra-observer variability, there was a mild increase in measurement variability for most geometrical and compositional volumetric RF–IVUS parameters. In RF–IVUS studies of mild-to-moderate coronary disease, analyzing less image frames saved analysis time, left most volumetric parameters greatly unaffected, and resulted in a no more than mild increase in measurement variability of volumetric data

    A systematic review of Vancouver B2 and B3 periprosthetic femoral fractures

    Get PDF
    Aims The aim of this study was to investigate the outcomes of Vancouver type B2 and B3 fractures by performing a systematic review of the methods of surgical treatment which have been reported. Materials and Methods A systematic search was performed in Ovid MEDLINE, Embase and the Cochrane Central Register of Controlled Trials. For inclusion, studies required a minimum of ten patients with a Vancouver type B2 and/or ten patients with a Vancouver type B3 fracture, a minimum mean follow-up of two years and outcomes which were matched to the type of fracture. Studies were also required to report the rate of re-operation as an outcome measure. The protocol was registered in the PROSPERO database. Results A total of 22 studies were included based on the eligibility criteria, including 343 B2 fractures and 167 B3 fractures. The mean follow-up ranged from 32 months to 74 months. Of 343 Vancouver B2 fractures, the treatment in 298 (86.8%) involved revision arthroplasty and 45 (12.6%) were treated with internal fixation alone. A total of 37 patients (12.4%) treated with revision arthroplasty and six (13.3%) treated by internal fixation only underwent further re-operation. Of 167 Vancouver B3 fractures, the treatment in 160 (95.8%) involved revision arthroplasty and eight (4.8%) were treated with internal fixation without revision. A total of 23 patients (14.4%) treated with revision arthroplasty and two (28.6%) treated only with internal fixation required re-operation. Conclusion A significant proportion, particularly of B2 fractures, were treated without revision of the stem. These were associated with a higher rate of re-operation. The treatment of B3 fractures without revision of the stem resulted in a high rate of re-operation. This demonstrates the importance of careful evaluation and accurate characterisation of the fracture at the time of presentation to ensure the correct management. There is a need for improvement in the reporting of data in case series recording the outcome of the surgical treatment of periprosthetic fractures. We have suggested a minimum dataset to improve the quality of data in studies dealing with these fractures

    Tea Consumption Enhances Endothelial-Dependent Vasodilation; a Meta-Analysis

    Get PDF
    Background: Tea consumption is associated with a lower risk of cardiovascular disease including stroke. Direct effects of tea components on the vasculature, particularly the endothelium, may partly explain this association. Objective: We performed a meta-analysis of controlled human intervention studies on the effect of tea on flow-mediated dilation (FMD) of the brachial artery, a measurement of endothelial function, which is suggested to be associated with cardiovascular risk. Methods: Human intervention studies were identified by systematic search of the databases Medline, Embase, Chemical Abstracts and Biosis through March 2009 and by hand-searching related articles. Studies were selected based on predefined criteria: intervention with tea as the sole experimental variable, placebo-controlled design, and no missing data on FMD outcome or its variability. A random effects model was used to calculate the pooled overall effect on FMD due to the intake of tea. The impact of various subject and treatment characteristics was investigated in the presence of heterogeneity. Results: In total, 9 studies from different research groups were included with 15 relevant study arms. The overall absolute increase in FMD of tea vs. placebo was 2.6 % of the arterial diameter (95 % CI: 1.8-3.3%; P-value,0.001) for a median daily dose of 500 mL of tea (2–3 cups). This is a relative increase of approximately 40 % compared to the average FMD of 6.3% measured under placebo or baseline conditions. There was significant heterogeneity between studies (P-value,0.001) tha

    A Reliability-Generalization Study of Journal Peer Reviews: A Multilevel Meta-Analysis of Inter-Rater Reliability and Its Determinants

    Get PDF
    Background: This paper presents the first meta-analysis for the inter-rater reliability (IRR) of journal peer reviews. IRR is defined as the extent to which two or more independent reviews of the same scientific document agree. Methodology/Principal Findings: Altogether, 70 reliability coefficients (Cohen’s Kappa, intra-class correlation [ICC], and Pearson product-moment correlation [r]) from 48 studies were taken into account in the meta-analysis. The studies were based on a total of 19,443 manuscripts; on average, each study had a sample size of 311 manuscripts (minimum: 28, maximum: 1983). The results of the meta-analysis confirmed the findings of the narrative literature reviews published to date: The level of IRR (mean ICC/r 2 =.34, mean Cohen’s Kappa =.17) was low. To explain the study-to-study variation of the IRR coefficients, meta-regression analyses were calculated using seven covariates. Two covariates that emerged in the metaregression analyses as statistically significant to gain an approximate homogeneity of the intra-class correlations indicated that, firstly, the more manuscripts that a study is based on, the smaller the reported IRR coefficients are. Secondly, if the information of the rating system for reviewers was reported in a study, then this was associated with a smaller IRR coefficient than if the information was not conveyed. Conclusions/Significance: Studies that report a high level of IRR are to be considered less credible than those with a low level o

    Effects of n-3 polyunsaturated fatty acid supplementation in pregnancy on maternal and fetal erythrocyte fatty acid composition

    No full text
    Objective: The aim of this study was to assess the effects of fish oil supplementation in pregnancy on maternal erythrocyte fatty acid composition at different stages of pregnancy and in the post-partum period, and on neonatal erythrocyte fatty acid composition.Design: A double-blind, randomised, placebo-controlled study.Setting: Subiaco, Western Australia.Subjects: In all, 98 women booked for delivery at St John of God Hospital, Subiaco, were recruited from private rooms of obstetricians. In total, 83 women and their healthy full-term babies completed the study.Intervention: Women received either 4 g of fish oil (n¼52) (56% docosahexaenoic acid (DHA) and 28% eicosapentaenoic acid(EPA) or placebo (olive oil) (n¼46) per day from 20 weeks gestation until delivery.Main outcome measures: Erythrocyte phospholipid fatty acids were measured in maternal peripheral blood at 20, 30 and 37 weeks of pregnancy and at 6 weeks post partum, and from cord blood collected at birth.Results: Compared to the control group, maternal EPA and DHA were significantly higher in the fish oil group at 30 and 37 weeks gestation, and remained elevated at 6 weeks post partum (Po0.001). The proportions of n-6 polyunsaturated(arachidonic acid, 22:3n-6 and 22:4n-6) were significantly lower in the fish oil supplemented group at the same time periods(Po0.001). Similarly, the proportions of EPA and DHA were significantly higher (Po0.001), and those of n-6 polyunsaturated fatty acids arachidonic acid, 20:3n-6, 22:3n-6 and 22:4n-6 were significantly lower (Po0.001), in erythrocytes from neonates in the fish oil group, compared to those in the control group.Conclusion: Fish oil supplementation from 20 weeks of pregnancy until birth is an effective means of enhancing n-3 fatty acid status of both mothers and neonates. Furthermore, the changes in maternal erythrocyte fatty acid composition are retained until at least 6 weeks post partum. It is essential to assess the effects of concomitant decreases in arachidonic acid status before anydietary recommendations can be made.Sponsorship: The study was supported by grants from the NH &amp; MRC and Raine Medical Research Foundation, Australia
    corecore