20 research outputs found

    Cross sectional TEM analysis of duplex HIPIMS and DC magnetron sputtered Mo and W doped carbon coatings

    Get PDF
    A FIB lift-out sample was made from a wear-resistant carbon coating deposited by high power impulse magnetron sputtering (HIPIMS) with Mo and W. TEM analysis found columnar grains extending the whole ∼1800 nm thick film. Within the grains, the carbon was found to be organised into clusters showing some onion-like structure, with amorphous material between them; energy dispersive X-ray spectroscopy (EDS) found these clusters to be Mo- and W-rich in a later, thinner sample of the same material. Electron energy-loss spectroscopy (EELS) showed no difference in C-K edge, implying the bonding type to be the same in cluster and matrix. These clusters were arranged into stripes parallel to the film plane, of spacing 7-8 nm; there was a modulation in spacing between clusters within these stripes that produced a second, coarser set of striations of spacing ∼37 nm

    Development of superlattice CrNNbN coatings for joint replacements deposited by High Power Impulse Magnetron Sputtering

    Get PDF
    The demand for reliable coating on medical implants is ever growing. In this research, enhanced performance of medical implants was achieved by a CrN/NbN coating utilising nanoscale multilayer/superlattice structure. The advantages of the novel High Power Impulse Magnetron Sputtering technology, namely its unique highly ionised plasma were exploited to deposit dense and strongly adherent coatings on Co-Cr implants. TEM analyses revealed coating superlattice structure with bi-layer thickness of 3.5 nm. CrN/NbN deposited on Co-Cr samples showed exceptionally high adhesion, critical load values of LC2= 50 N in scratch adhesion tests. Nanoindentation tests showed high hardness of 34 GPa and Young's modulus of 447 GPa. Low coefficient of friction (µ) 0.49 and coating wear coefficient (KC) = 4.94 x 10-16 m3N-1m-1 were recorded in dry sliding tests. Metal ion release studies showed a reduction in Co, Cr and Mo release at physiological and elevated temperatures, (70 oC) to almost undetectable levels (<1 ppb). Rotating beam fatigue testing showed a significant increase in fatigue strength from 349±59 MPa (uncoated) to 539±59 MPa (coated). In vitro biological testing has been performed in order to assess the safety of the coating in biological environment, cytotoxicity, genotoxicity and sensitisation testing have been performed, all showing no adverse effects. Keywords: Orthopaedic implant, High Power Impulse Magnetron Sputtering, Superlattice coating, Corrosion, Biocompatibility

    Substrate finishing and niobium content effects on the high temperature corrosion resistance in steam atmosphere of CrN/NbN superlattice coatings deposited by PVD-HIPIMS

    Get PDF
    The main objective of this work was to evaluate the oxidation resistance of three PVD-HIPIMS CrN/NbN coatings, studying the effect of the surface finishing of the substrate and the role of niobium content into the coating composition. CrN/NbN nano-multilayered films on P92 steel were tested at 650°C in pure steam atmosphere. The mass gain was measured at fixed intervals to study their oxidation kinetics. The morphology and thickness of nanoscales were measured by transmission electron microscopy (TEM). Characterization of coatings before and after the thermal treatment was performed by scanning electron microscopy-energy with facilities of dispersive X-ray spectroscopy (SEM–EDX) and X-ray diffraction (XRD). All coatings improved the oxidation resistance of the substrate material, but the best behaviour was exhibited by the CrN/NbN with the high niobium (Nb) content and deposited on the substrate with the finest surface finishing

    Enhanced sulphidation/oxidation resistance of Ti–45Al–8Nb alloy by multilayered coatings at 850°C for up to 675 h

    No full text
    The high temperature sulphidation/oxidation behaviour of three multilayered coatings CrAlYN/CrN etched by Y+, CrAlYN/CrN etched by Cr+and CrAlYN/CrN etched CrAlzand the uncoated γ-TiAl (Ti-45Al-8Nb (at-%) used as reference sample was studied at 850°C for 675 h. Sulphidation/oxidation test was performed in the environment of H2/H2S/H2O, yielding pS2=10-1Pa and pO2=10-18Pa. Kinetic data obtained by discontinuous gravimetric method showed that the multilayered coatings effectively enhanced the sulphidation/oxidation resistance of γ-TiAl alloy. The corrosion resistance decreasing in order: CrAlYN/CrN etched by γ+>CrAlYN/CrN etched by CrAl+>CrAlYN/CrN etched by Cr+>γ-TiAl. Scale development studies using SEM, EDX and X-ray diffraction confirmed two regions of the coated materials: 'affected,' where coating cracked and developed non-protective TiO2scale, and 'unaffected,' where protective (Al, Cr)2O3scale formed. The uncoated γ-TiAl material, after exposure, showed a typical multilayered structure consisting of layers of TiO2and Al2O3