9 research outputs found
Impact of the second reader on screening outcome at blinded double reading of digital screening mammograms
BACKGROUND: To determine the impact of the second reader on screening outcome at blinded double reading of digital screening mammograms. METHODS: We included a consecutive series of 99,013 digital screening mammograms, obtained between July 2013 and January 2015 and double read in a blinded fashion. During 2-year follow-up, we collected radiology, surgery and pathology reports of recalled women. RESULTS: Single reading resulted in 2928 recalls and 616 screen-detected cancers (SDCs). The second reader recalled another 612 women, resulting in 82 additional SDCs. Addition of the second reader increased the recall rate (3.0% to 3.6%, p < 0.001), cancer detection rate (6.2-7.0 per 1000 screens, p < 0.001) and false positive recall rate (24.4-28.7 per 1000 screens, p < 0.001). Positive predictive value of recall (21.0% vs. 19.7%, p = 0.20) and of biopsy (52.1% vs. 50.9%, p = 0.56) were comparable for single reading and blinded double reading. Tumour characteristics were comparable for cancers detected by the first reader and cancers additionally detected by the second reader, except of a more favourable tumour grade in the latter group. CONCLUSIONS: At blinded double reading, the second reader significantly increases the cancer detection rate, at the expense of an increased recall rate and false positive recall rate
Impact of the digitalisation of mammography on performance parameters and breast dose in the Flemish Breast Cancer Screening Programme
To investigate the impact of digitalisation on performance parameters and breast dose of the Flemish Breast Cancer Screening Programme. Both computed (CR) and direct radiography (DR) are compared with screen-film mammography (SFM).
Data from 975,673 mammographic examinations were collected from units which underwent digitalisation from SFM to CR (41 units) or DR (72 units) in the period 2005-2011. Performance indicators were obtained by consulting the Screening Programme database. Phantom and patient dosimetry data were acquired from the physical technical quality assurance of the programme.
Digitalisation induced no significant change in cancer detection rate (CDR), percentage of ductal carcinomas in situ and percentage of breast cancers smaller than 1 cm. A decrease in false-positive results and third readings was observed, which was a time-related observation. After digitalisation, positive predictive value (PPV) increased and recall rates decreased. Compared with SFM, an increase of 30 % in mean glandular dose (MGD) was found for CR, while a similar change in the opposite direction was found for DR.
No major differences in performance parameters after digitalisation were found. Transition of SFM to CR resulted in a higher MGD and associated lower detection-over-induction ratio (DIR), while the change to DR induced an improvement of DIR.
* Performance parameters showed no major differences after digitalisation to CR or DR.
* Transition from SFM to CR results in a higher mean glandular dose.
* Transition from SFM to DR results in a lower mean glandular dose