15 research outputs found

    Performance evaluation of a new fourth-generation HIV combination antigen-antibody assay.

    Get PDF
    Education and diagnostic tests capable of early detection represent our most effective means of preventing transmission of human immunodeficiency virus (HIV). The importance of early detection is underlined by studies demonstrating increased life expectancy following early initiation of antiviral treatment. The Elecsys(®) HIV combi PT assay is a fourth-generation antigen-antibody combination assay developed to allow earlier detection of seroconversion, and to have increased sensitivity and improved specificity. We aimed to determine how early the assay could detect infection compared with existing assays; whether all HIV variants could be detected; and the assay's specificity using samples from blood donors, routine specimens, and patients with potential cross-reacting factors. Samples were identified as positive by the Elecsys(®) assay 4.9 days after a positive polymerase chain reaction result (as determined by the panel supplier), which was earlier than the 5.3-7.1 days observed with comparators. The analytical sensitivity of the Elecsys(®) HIV combi PT assay for the HIV-1 p24 antigen was 1.05 IU/mL, which compares favorably with the comparator assays. In addition, the Elecsys(®) assay identified all screened HIV subtypes and displayed greater sensitivity to HIV-2 homologous antigen and antibodies to HIV-1 E and O and HIV-2 than the other assays. Overall, the specificity of the Elecsys(®) assay was 99.88 % using samples from blood donors and 99.81 % when analyzing unselected samples. Potential cross-reacting factors did not interfere with assay performance. The Elecsys(®) HIV combi PT assay is a sensitive and specific assay that has been granted the CE mark according to Directive 2009/886/EC

    Multicenter study of a new fully automated HBsAg screening assay with enhanced sensitivity for the detection of HBV mutants.

    No full text
    In a multicenter study a new, fully automated Roche Diagnostics Elecsys HBsAg II screening assay with improved sensitivity to HBsAg mutant detection was compared to well-established HBsAg tests: AxSYM HBsAg V2 (Abbott), Architect HBsAg (Abbott), Advia Centaur HBsAg (Bayer) Enzygnost HBsAg 5.0 (Dade-Behring), and Vitros Eci HBsAg (Ortho). A total of 16 seroconversion panels, samples of 60 HBsAg native mutants, and 31 HBsAg recombinant mutants, dilution series of NIBSC and PEI standards, 156 HBV positive samples comprising genotypes A to G, 686 preselected HBsAg positive samples from different stages of infection, 3,593 samples from daily routine, and 6,360 unselected blood donations were tested to evaluate the analytical and clinical sensitivity, the detection of mutants, and the specificity of the new assay. Elecsys HBsAg II showed a statistically significant better sensitivity in seroconversion panels to the compared tests. Fifty-seven out of 60 native mutants and all recombinant mutants were found positive. Among 156 HBV samples with different genotypes and 696 preselected HBsAg positive samples Elecsys HBsAg II achieved a sensitivity of 100%. The lower detection limit for NIBSC standard was calculated to be 0.025 IU/ml and for the PEI standards ad and ay it was <0.001 and <0.005 U/ml, respectively. Within 2,724 daily routine specimens and 6.360 unselected blood donations Elecsys HBsAg II showed a specificity of 99.97 and 99.88%, respectively. In conclusion the new Elecsys HBsAg II shows a high sensitivity for the detection of all stages of HBV infection and HBsAg mutants paired together with a high specificity in blood donors, daily routine samples, and potentially interfering sera
    corecore