8 research outputs found

    Reduction in stiffness of proximal leg muscles during the first 6 months of glucocorticoid therapy for giant cell arteritis: A pilot study using shear wave elastography.

    Get PDF
    Aim: To investigate muscle stiffness changes in patients treated for giant cell arteritis (GCA) with high‐dose oral glucocorticoids. Methods: Using ultrasound elastography, shear wave velocity (SWV) was measured in the quadriceps, hamstrings and biceps brachii muscles of 14 patients with GCA (4 male, mean age ± SD, 68.2 ± 4.3 years) within the first 2 weeks of initiating glucocorticoid treatment (baseline) and repeated after 3 and 6 months treatment. Muscle strength and performance tests were performed at each visit. Baseline measures were compared with those from 14 healthy controls. Linear mixed models were used to test for change in patient measures over time. Results: At baseline, muscle SWV in patients was not significantly different from controls. With glucocorticoid treatment, there was a reduction in SWV in the leg but not the arm muscles. SWV decreased by a mean of 14% (range 8.3%‐17.3%; P = .001) after 3 months and 18% (range 10.2%‐25.3%; P < .001) after 6‐months in the quadriceps and hamstrings during the resting position. The baseline, 3 and 6 months mean SWV (±SD) for the vastus lateralis were 1.62 ± 0.16 m/s, 1.40 ± 0.10 m/s and 1.31 ± 0.06 m/s, respectively (P < .001). In the patient group as a whole, there was no significant change in muscle strength. However, there were moderate correlations (r = .54‐.69) between exhibiting weaker muscle strength at follow‐up visits and a greater reduction in SWV. Conclusion: Glucocorticoid therapy in patients with GCA was associated with a significant reduction in proximal leg muscle stiffness during the first 6 months. Future research should study a larger sample of patients for a longer duration to investigate if diminished muscle stiffness precedes signs of glucocorticoid‐induced myopathy

    The effect of ageing on shear wave elastography muscle stiffness in adults

    No full text
    Background: Skeletal muscle undergoes structural changes with ageing which may alter its biomechanical properties. Shear wave elastography (SWE) may detect these changes by measuring muscle stiffness. Aims: To investigate muscle stiffness in healthy young, middle-aged and elderly cohorts using SWE and correlate it with muscle strength and mass. Methods: Shear wave velocity (SWV) was measured in the quadriceps, hamstrings and biceps brachii of 26 young (range 20–35 years), 21 middle-aged (40–55) and 30 elderly (77–94) volunteers. The participants performed several muscle tests to evaluate their strength. The One-way ANOVA was used to test the muscle stiffness differences between the groups and the Pearson’s correlation coefficient to evaluate the relationship between SWV and muscle strength. Results: The overall resting muscle SWV gradually decreased with age but was only significantly reduced in the elderly group (p < 0.001); with the exception of the vastus lateralis SWV where a significant difference was noted (p < 0.05) between young (1.77 m/s), middle-aged (1.64 m/s) and elderly (1.48 m/s). The elderly group had on average 16.5% lower muscle stiffness compared to the young. SWV significantly correlated with muscle mass (r = 0.316), walking time (r = − 0.560), number of chair stands (r = 0.522), handgrip strength (r = 0.436) and isokinetic knee strength (r = 0.640). Sex and BMI did not explain any significant variation in SWV. Conclusions: Ageing was associated with a decline in skeletal muscle stiffness which positively correlates with muscle weakness. Further research is needed to evaluate the promising role of SWE as a biomarker for sarcopenia assessment and potential falls risk prediction in elderly individuals

    Shear-Wave Elastography of Benign versus Malignant Musculoskeletal Soft-Tissue Masses: Comparison with Conventional US and MRI

    Get PDF
    Purpose: To examine if shear-wave elastography (SWE) improves the accuracy of diagnosing soft-tissue masses as benign or malignant compared with US alone or in combination with MRI. Materials and Methods: Two hundred six consecutive adult participants (mean age, 57.7 years; range, 18–91 years), including 89 men (median age, 56.0 years; range, 21–91 years) and 117 women (median age, 59.1 years; range, 18–88 years), who were referred for biopsy of a soft-tissue mass were prospectively recruited from December 2015 through March 2017. Participants underwent B-mode US, MRI, and SWE prior to biopsy. Three musculoskeletal radiologists independently reviewed US images alone, followed by US and MRI images together, and classified lesions as benign, probably benign, probably malignant, or malignant. For SWE, the area under the receiver operating characteristic (ROC) curve (AUC) was calculated for transverse shear-wave velocity (SWV). Multivariable logistic regression was used to investigate the association between SWE and malignancy alongside individual demographic and imaging variables. Results: At histologic examination, 79 of 206 (38%) participants had malignant lesions. SWV showed good diagnostic accuracy for lesions classified as benign or probably benign by US alone (AUC = 0.87 [95% confidence interval {CI}: 0.79, 0.95]). SWV did not provide substantive diagnostic information for lesions classified as probably malignant or malignant, whether the classification was made with or without MRI. However, multivariable modeling indicated that diagnostic accuracy may vary by lesion position (interaction P = .02; superficial, odds ratio [OR] = 17.7 [95% CI: 1.50, 207], P = .02; deep/mixed, OR = 0.24 [95% CI: 0.07, 0.86], P = .03) and participant age (interaction P = .01; eg, age 43 years, OR = 0.72 [95% CI: 0.15, 3.5], P = .69; age 72 years, OR = 0.08 [95% CI: 0.02, 0.37], P = .001). Conclusion: Shear-wave elastography can increase accuracy of soft-tissue lesion diagnosis in conjunction with US. However, a single cut-off may not be universally applicable with diagnostic accuracy that is affected by lesion position and patient age

    Muscle shear wave elastography in idiopathic inflammatory myopathies: a case–control study with MRI correlation

    Get PDF
    Objective: To investigate muscle stiffness in patients with idiopathic inflammatory myopathies (IIM) using shear wave elastography (SWE) and to correlate the results with muscle strength and MRI features of myositis. Materials and methods: Muscle shear wave velocity (SWV) was measured in 23 active IIM patients (13 females, mean age 50.4 ± 16.1 years) and 23 matched healthy controls (13 females, mean age 50.7 ± 16.2 years). The investigated muscles included the vastus lateralis (VL), rectus femoris (RF), vastus medialis (VM) vastus intermedius (VI), biceps femoris (BF), semitendinosus (ST), semimembranosus (SM) and the biceps brachii (BB) scanned during relaxed resting and passive stretching positions. Participants performed multiple tests to evaluate their muscle strength. IIM patients had a thigh MRI to assess degrees of oedema, fatty infiltration and atrophy. Results: In the resting position, IIM patients had a 12.9-22.2% significantly lower SWV (p < 0.05) for the quadriceps and hamstrings, but not BB. There was no difference during passive stretching. The SWV for VL, VI and BF showed moderate correlations with the muscle strength tests ranging from r = 0.47 to r = 0.70 (all p < 0.05). Lower SWV was associated with greater MRI scores of oedema (p = 0.001) and atrophy (p = 0.006). However, SWV did not correlate with fatty infiltration (r < 0.3; p = 0.28), creatine kinase (r = 0.28; p = 0.19) or disease duration (r = 0.26; p = 0.24). Conclusion: Shear wave elastography may detect abnormal reduced thigh stiffness in IIM patients. SWE measurements were significantly associated with muscle weakness and MRI signs of oedema and atrophy. Future research should investigate this new technology for monitoring disease activity

    An investigation into the variability between different shear wave elastography systems in muscle

    No full text
    Aims: The reliability and agreement between shear wave elastography (SWE) systems using different acquisition methods in muscles is not yet established. The objectives were to determine the reliability of a new SWE system on normal resting muscles using different acquisition methods and to compare its performance to an established state-of-the-art system. Material and methods: Small, medium and large ROI sizes in addition to longitudinal, oblique and transverse orientations over five different locations within the rectus femoris muscle were tested using the new system. Results were compared to the established system to test for inter-system reproducibility. Results: Lowest within-subject coefficient of variance (4.3%) and shear wave velocity (1.83 m/s) were associated with the medium ROI and longitudinal orientation from the lateral location. This combination resulted in a strong internal agreement of intra-class correlation of 0.76 (0.57–0.89) for the new system and an almost perfect agreement of 0.92 (0.82–0.97) for the established. Inter-system reproducibility for the best combination was 0.71 (0.48–1) with a mean velocity difference ±95% limits of agreement of 0.07±0.49 m/s. Conclusions: Altering SWE acquisition methods can produce variable results. The new system produced reliable results that are comparable with but not as reliable as the established
    corecore