894 research outputs found
Recommended from our members
Impact of physiological noise correction on detecting blood oxygenation level-dependent contrast in the breast.
Physiological fluctuations are expected to be a dominant source of noise in blood oxygenation level-dependent (BOLD) magnetic resonance imaging (MRI) experiments to assess tumour oxygenation and angiogenesis. This work investigates the impact of various physiological noise regressors: retrospective image correction (RETROICOR), heart rate (HR) and respiratory volume per unit time (RVT), on signal variance and the detection of BOLD contrast in the breast in response to a modulated respiratory stimulus. BOLD MRI was performed at 3 T in ten volunteers at rest and during cycles of oxygen and carbogen gas breathing. RETROICOR was optimized using F-tests to determine which cardiac and respiratory phase terms accounted for a significant amount of signal variance. A nested regression analysis was performed to assess the effect of RETROICOR, HR and RVT on the model fit residuals, temporal signal-to-noise ratio, and BOLD activation parameters. The optimized RETROICOR model accounted for the largest amount of signal variance ([Formula: see text] = 3.3 ± 2.1%) and improved the detection of BOLD activation (P = 0.002). Inclusion of HR and RVT regressors explained additional signal variance, but had a negative impact on activation parameter estimation (P < 0.001). Fluctuations in HR and RVT appeared to be correlated with the stimulus and may contribute to apparent BOLD signal reactivity.This work was supported by the NIHR Cambridge Biomedical Research Centre, the Cambridge Experimental Cancer Medicine Centre and the CRUK-EPSRC Cancer Imaging Centre in Cambridge and Manchester (C197/A16465 and C8742/A18097)
Imaging Carotid Atherosclerosis Plaque Ulceration: Comparison of Advanced Imaging Modalities and Recent Developments.
Atherosclerosis remains the leading cause of long-term mortality and morbidity worldwide, despite remarkable advancement in its management. Vulnerable atherosclerotic plaques are principally responsible for thromboembolic events in various arterial territories such as carotid, coronary, and lower limb vessels. Carotid plaque ulceration is one of the key features associated with plaque vulnerability and is considered a notable indicator of previous plaque rupture and possible future cerebrovascular events. Multiple imaging modalities have been used to assess the degree of carotid plaque ulceration for diagnostic and research purposes. Early diagnosis and management of carotid artery disease could prevent further cerebrovascular events. In this review, we highlight the merits and limitations of various imaging techniques for identifying plaque ulceration
Recommended from our members
Comparison of breath-hold, respiratory navigated and free-breathing MR elastography of the liver
Hepatic magnetic resonance elastography (MRE) is currently a breath-hold imaging technique. Patients with chronic liver disease can have comorbidities that limit their ability to breath-hold (BH) for the required acquisition time. Our aim was to evaluate whether stiffness measurements obtained from a navigator-triggered MRE acquisition are comparable to standard expiratory breath-hold, inspiratory breath-hold or free-breathing in healthy participants.
Twelve healthy participants were imaged using the four methods on a clinical 1.5 T MR system equipped with a product MRE system. Mean liver stiffness, and measurable area of stiffness (with a confidence threshold >95%) were compared between sequences using the concordance correlation coefficient. Repeatability of each sequence between two acquisitions was also assessed.
The standard BH expiratory technique had high concordance with the navigated technique (r = 0.716), and low concordance with the BH inspiration (r = 0.165) and free-breathing (r = 0.105) techniques. The navigator-triggered technique showed no statistical difference in measurable area of liver or in repeatability compared with the standard expiratory acquisition (p = 0.997 and p = 0.407 respectively). The free-breathing technique produced less measurable liver area and was less repeatable than the alternative techniques. The increase in acquisition time for navigator techniques was 3 min 6 s compared to standard expiratory breath-hold.
Navigator-based hepatic MRE measurements are comparable to the reference standard expiratory breath-hold acquisition in healthy participants.This work was supported by the Addenbrooke's Charitable Trust and the NIHR Comprehensive Biomedical Research Centre award to Cambridge University Hospitals NHS Foundation Trust in partnership with the University of Cambridge
What is a hospital bed day worth? A contingent valuation study of hospital Chief Executive Officers
BACKGROUND: Decreasing hospital length of stay, and so freeing up hospital beds, represents an important cost saving which is often used in economic evaluations. The savings need to be accurately quantified in order to make optimal health care resource allocation decisions. Traditionally the accounting cost of a bed is used. We argue instead that the economic cost of a bed day is the better value for making resource decisions, and we describe our valuation method and estimations for costing this important resource. METHODS: We performed a contingent valuation using 37 Australian Chief Executive Officers’ (CEOs) willingness to pay (WTP) to release bed days in their hospitals, both generally and using specific cases. We provide a succinct thematic analysis from qualitative interviews post survey completion, which provide insight into the decision making process. RESULTS: On average CEOs are willing to pay a marginal rate of 436 for an Intensive Care Unit (ICU) bed day, with estimates of uncertainty being greater for ICU beds. These estimates are significantly lower (four times for ward beds and seven times for ICU beds) than the traditional accounting costs often used. Key themes to emerge from the interviews include the importance of national funding and targets, and their associated incentive structures, as well as the aversion to discuss bed days as an economic resource. CONCLUSIONS: This study highlights the importance for valuing bed days as an economic resource to inform cost effectiveness models and thus improve hospital decision making and resource allocation. Significantly under or over valuing the resource is very likely to result in sub-optimal decision making. We discuss the importance of recognising the opportunity costs of this resource and highlight areas for future research. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1186/s12913-017-2079-5) contains supplementary material, which is available to authorized users
Recommended from our members
Amniotic fluid volume: Rapid MR-based assessment at 28-32 weeks gestation.
OBJECTIVES: This work evaluates rapid magnetic resonance projection hydrography (PH) based amniotic fluid volume (AFV) estimates against established routine ultrasound single deepest vertical pocket (SDVP) and amniotic fluid index (AFI) measurements, in utero at 28-32 weeks gestation. Manual multi-section planimetry (MSP) based measurement of AFV is used as a proxy reference standard. METHODS: Thirty-five women with a healthy singleton pregnancy (20-41 years) attending routine antenatal ultrasound were recruited. SDVP and AFI were measured using ultrasound, with same day MRI assessing AFV with PH and MSP. The relationships between the respective techniques were assessed using linear regression analysis and Bland-Altman method comparison statistics. RESULTS: When comparing estimated AFV, a highly significant relationship was observed between PH and the reference standard MSP (R(2) = 0.802, p < 0.001). For the US measurements, SDVP measurement related most closely to amniotic fluid volume, (R(2) = 0.470, p < 0.001), with AFI demonstrating a weaker relationship (R(2) = 0.208, p = 0.007). CONCLUSION: This study shows that rapid MRI based PH measurement is a better predictor of AFV, relating more closely to our proxy standard than established US techniques. Although larger validation studies across a range of gestational ages are required this approach could form part of MR fetal assessment, particularly where poly- or oligohydramnios is suspected. KEY POINTS: • MR projection hydrography can be used to estimate amniotic fluid volume. • MR projection hydrography relies on the T2w signal from amniotic fluid. • Amniotic fluid volume (AFV) is more accurately assessed than with ultrasound.This study was supported by the National Institute of Health Research, Cambridge Biomedical Research Centre. The authors also acknowledge the support of Addenbrooke’s Charitable Trust and thank the participants for their contribution to the study.This is the author accepted manuscript. The final version is available from Springer via http://dx.doi.org/10.1007/s00330-015-4179-
Hypertensive patients' use of blood pressure monitors stationed in pharmacies and other locations: a cross-sectional mail survey
<p>Abstract</p> <p>Background</p> <p>Blood pressure (BP) monitors are commonly stationed in public places such as pharmacies, but it is uncertain how many people with hypertension currently use them. We sought to estimate the proportion of hypertensive patients who use these types of monitors and examine whether use varies by demographic or health characteristics.</p> <p>Methods</p> <p>We conducted a cross-sectional mail survey of hypertensive adults enrolled in a practice based research network of 24 primary care practices throughout the state of North Carolina. We analyzed results using descriptive statistics and examined bivariate associations using chi-square and independent associations using logistic regression.</p> <p>Results</p> <p>We received 530 questionnaires (76% response rate). Of 333 respondents (63%) who reported checking their BP in locations other than their doctor's office or home, 66% reported using a monitor stationed in a pharmacy. Younger patients more commonly reported using pharmacy monitors (48% among those < 45 years vs 35% of those over 65, p = 0.04). Blacks reported using them more commonly than whites (48% vs 39%, p = 0.03); and high school graduates more often than those with at least some college (50% vs 37%, p = 0.02). In multivariate analysis, younger age (aOR 1.49; 95% CI 1.00–2.21 for those age 45 to 65 years vs those > 65 years old) and high school education (aOR 1.74; 95% CI 1.13–2.58) were associated with use of pharmacy-stationed monitors, but Black race was not. Patients with diabetes, heart disease, or stroke were not more likely to use pharmacy-stationed monitors.</p> <p>Conclusion</p> <p>Hypertensive patients' use of BP monitors located in pharmacies is common. Younger patients, Blacks, and those with high school education were slightly more likely to report using them. Because use of these monitors is so common, efforts to ensure their accuracy are important.</p
Unicompartmental knee arthroplasty in patients aged less than 65: Combined data from the Australian and Swedish Knee Registries
Introduction and purpose: In recent years, there has been renewed interest in using unicompartmental knee arthroplasty (UKA). Several studies have reported increasing numbers of UKAs for osteoarthritis in patients who are less than 65 years of age, with low revision rates. To describe and compare the use and outcome of UKA in this age group, we have combined data from the Australian and Swedish knee registries. Patients and methods: More than 34,000 UKA procedures carried out between 1998 and 2007 were analyzed, and we focused on over 16,000 patients younger than 65 years to determine usage and to determine differences in the revision rate. Survival analysis was used to determine outcomes of revision related to age and sex, using any reason for revision as the endpoint. Results: Both countries showed a decreasing use of UKA in recent years in terms of the proportion of knee replacements and absolute numbers undertaken per year. The 7-year cumulative risk of revision of UKA in patients younger than 65 years was similar in the two countries. Patients younger than 55 years had a statistically significantly higher cumulative risk of revision than patients aged 55 to 64 years (19% and 12%, respectively at 7 years). The risk of revision in patients less than 65 years of age was similar in both sexes. Interpretation: The results of the combined UKA data from the Australian and Swedish registries show a uniformity of outcome between countries with patients aged less than 65 having a higher rate of revision than patients who were 65 or older. Surgeons and patients should be aware of the higher risk of revision in this age group.Annette W-Dahl, Otto Robertsson, Lars Lidgren, Lisa Miller, David Davidson, Stephen Graves
Activation of Ventral Tegmental Area 5-HT2C Receptors Reduces Incentive Motivation
FUNDING AND DISCLOSURE The research was funded by Wellcome Trust (WT098012) to LKH; and National Institute of Health (DK056731) and the Marilyn H. Vincent Foundation to MGM. The University of Michigan Transgenic Core facility is partially supported by the NIH-funded University of Michigan Center for Gastrointestinal Research (DK034933). The remaining authors declare no conflict of interest. ACKNOWLEDGMENTS We thank Dr Celine Cansell, Ms Raffaella Chianese and the staff of the Medical Research Facility for technical assistance. We thank Dr Vladimir Orduña for the scientific advice and technical assistance.Peer reviewedPublisher PD
The effectiveness of public health interventions to reduce the health impact of climate change:a systematic review of systematic reviews
Climate change is likely to be one of the most important threats to public health in the coming years. Yet despite the large number of papers considering the health impact of climate change, few have considered what public health interventions may be of most value in reducing the disease burden. We aimed to evaluate the effectiveness of public health interventions to reduce the disease burden of high priority climate sensitive diseases
- …