12 research outputs found

    2D-fluoroscopic navigated percutaneous screw fixation of pelvic ring injuries - a case series

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Screw fixation of pelvic ring fractures is a common, but demanding procedure and navigation techniques were introduced to increase the precision of screw placement. The purpose of this case series was the evaluation of screw misplacement rate and functional outcome of percutaneous screw fixation of pelvic ring disruptions using a 2D navigation system.</p> <p>Methods</p> <p>Between August 2004 and December 2007, 44 of 442 patients with pelvic injuries were included for closed reduction and percutaneous screw fixation of disrupted pelvic ring lesions using an optoelectronic 2D-fluoroscopic based navigation system. Operating and fluoroscopy time were measured, as well as peri- and postoperative complications documented. Screw position was assessed by postoperative CT scans. Quality of live was evaluated by SF 36-questionnaire in 40 of 44 patients at mean follow up 15.5 ± 1.2 month.</p> <p>Results</p> <p>56 iliosacral- and 29 ramus pubic-screws were inserted (mean operation time per screw 62 ± 4 minutes, mean fluoroscopy time per screw 123 ± 12 seconds). In post-operative CT-scans the screw position was assessed and graded as follows: I. secure positioning, completely in the cancellous bone (80%); II. secure positioning, but contacting cortical bone structures (14%); III. malplaced positioning, penetrating the cortical bone (6%). The malplacements predominantly occurred in bilateral overlapping screw fixation. No wound infection or iatrogenic neurovascular damage were observed. Four re-operations were performed, two of them due to implant-misplacement and two of them due to implant-failure.</p> <p>Conclusion</p> <p>2D-fluoroscopic navigation is a safe tool providing high accuracy of percutaneous screw placement for pelvic ring fractures, but in cases of a bilateral iliosacral screw fixation an increased risk for screw misplacement was observed. If additional ramus pubic screw fixations are performed, the retrograde inserted screws have to pass the iliopubic eminence to prevent an axial screw loosening.</p

    Outcome of long-axis percutaneous sacroplasty for the treatment of sacral insufficiency fractures.

    Get PDF
    Our aim was to assess the clinical outcome of patients who were subjected to long-axis sacroplasty for the treatment of sacral insufficiency fractures. Nineteen patients with unilateral (n = 3) or bilateral (n = 16) sacral fractures were involved. Under local anaesthesia, each patient was subjected to CT-guided sacroplasty using the long-axis approach through a single entry point. An average of 6 ml of polymethylmethacrylate (PMMA) was delivered along the path of each sacral fracture. For each individual patient, the Visual Analogue pain Scale (VAS) before sacroplasty and at 1, 4, 24 and 48 weeks after the procedure was obtained. Furthermore, the use of analgesics (narcotic/non-narcotic) along with the evolution of post-interventional patient mobility before and after sacroplasty was also recorded. The mean pre-procedure VAS was 8 +/- 1.9 (range, 2 to 10). This rapidly and significantly (P &lt; 0.001) declined in the first week after the procedure (mean 4 +/- 1.4; range, 1 to 7) followed by a gradual and significant (P &lt; 0.001) decrease along the rest of the follow-up period at 4 weeks (mean 3 +/- 1.1; range, 1 to 5), 24 weeks (mean 2.2 +/- 1.1; range, 1 to 5) and 48 weeks (mean 1.6 +/- 1.1; range, 1 to 5). Eleven (58%) patients were under narcotic analgesia before sacroplasty, whereas 8 (42%) patients were using non-narcotics. Corresponding values after the procedure were 2/19 (10%; narcotic, one of them was on reserve) and 10/19 (53%; non-narcotic). The remaining 7 (37%) patients did not address post-procedure analgesic use. The evolution of post-interventional mobility was favourable in the study group as they revealed a significant improvement in their mobility point scale (P &lt; 0.001). Long-axis percutaneous sacroplasty is a suitable, minimally invasive treatment option for patients who present with sacral insufficiency fractures. More studies with larger patient numbers are needed to explore any unrecognised limitations of this therapeutic approach
    corecore