598 research outputs found
Development of a Momentum Determined Electron Beam in the 1 -45 GeV Range
A beam line for electrons with energies in the range of 1 to 45 GeV, low
contamination of hadrons and muons and high intensity up to 10^6 per
accelerator spill at 27 GeV was setup at U70 accelerator in Protvino, Russia. A
beam tagging system based on drift chambers with 160 micron resolution was able
to measure relative electron beam momentum precisely. The resolution sigma_p p
was 0.13% at 45 GeV where multiple scattering is negligible. This test beam
setup provided the possibility to study properties of lead tungstate crystals
(PbWO_4) for the BTeV experiment at Fermilab.Comment: 12 pages, 8 figures; work done by the BTeV Electromagnetic
Calorimeter grou
Performance of a fine-sampling electromagnetic calorimeter prototype in the energy range from 1 to 19 GeV
The fine-sampling electromagnetic calorimeter prototype has been
experimentally tested using the 1-19 GeV/c tagged beams of negatively charged
particles at the U70 accelerator at IHEP, Protvino. The energy resolution
measured by electrons is Delta{E}/E=2.8%/\sqrt{E} + 1.3%. The position
resolution for electrons is Delta{x}=3.1 + 15.4/sqrt{E} mm in the center of the
cell. The lateral non-uniformity of the prototype energy response to electrons
and MIPs has turned out to be negligible. Obtained experimental results are in
a good agreement with Monte-Carlo simulations.Comment: Article is prepared for pdflatex using the class elsart. 13 pages, 9
figures in 11 PDF file
Comparison of Radiation Damage in Lead Tungstate Crystals under Pion and Gamma Irradiation
Studies of the radiation hardness of lead tungstate crystals produced by the
Bogoroditsk Techno-Chemical Plant in Russia and the Shanghai Institute of
Ceramics in China have been carried out at IHEP, Protvino. The crystals were
irradiated by a 40-GeV pion beam. After full recovery, the same crystals were
irradiated using a -ray source. The dose rate profiles along
the crystal length were observed to be quite similar. We compare the effects of
the two types of radiation on the crystals light output.Comment: 10 pages, 8 figures, Latex 2e, 28.04.04 - minor grammatical change
Correlation of Beam Electron and LED Signal Losses under Irradiation and Long-term Recovery of Lead Tungstate Crystals
Radiation damage in lead tungstate crystals reduces their transparency. The
calibration that relates the amount of light detected in such crystals to
incident energy of photons or electrons is of paramount importance to
maintaining the energy resolution the detection system. We report on tests of
lead tungstate crystals, read out by photomultiplier tubes, exposed to
irradiation by monoenergetic electron or pion beams. The beam electrons
themselves were used to measure the scintillation light output, and a blue
light emitting diode (LED) was used to track variations of crystals
transparency. We report on the correlation of the LED measurement with
radiation damage by the beams and also show that it can accurately monitor the
crystals recovery from such damage.Comment: 9 pages, 6 figures, LaTeX2
LED Monitoring System for the BTeV Lead Tungstate Crystal Calorimeter Prototype
We report on the performance of a monitoring system for a prototype
calorimeter for the BTeV experiment that uses Lead Tungstate crystals coupled
with photomultiplier tubes. The tests were carried out at the 70 GeV
accelerator complex at Protvino, Russia.Comment: 12 pages, 8 figures, LaTeX2e, revised versio
Design and performance of LED calibration system prototype for the lead tungstate crystal calorimeter
A highly stable monitoring system based on blue and red light emitting diodes
coupled to a distribution network comprised of optical fibers has been
developed for an electromagnetic calorimeter that uses lead tungstate crystals
readout with photomultiplier tubes. We report of the system prototype design
and on the results of laboratory tests. Stability better than 0.1% (r.m.s.) has
been achieved during one week of prototype operation.Comment: 10 pages, 6 figures, LaTeX2
Study of Radiation Damage in Lead Tungstate Crystals Using Intense High Energy Beams
We report on the effects of radiation on the light output of lead tungstate
crystals. The crystals were irradiated by pure, intense high energy electron
and hadron beams as well as by a mixture of hadrons, neutrons and gammas. The
crystals were manufactured in Bogoroditsk, Apatity (both Russia), and Shanghai
(China). These studies were carried out at the 70-GeV proton accelerator in
Protvino
High statistics study of the K- -> pi0 e- nu decay
The decay K- -> pi0 e- nu has been studied using in-flight decays detected
with the "ISTRA+" spectrometer working at the 25 GeV negative secondary beam of
the U-70 PS. About 550K events were used for the analysis. The lambda+
parameter of the vector form-factor has been measured: lambda+ = 0.0286 +-
0.0008 (stat) +- 0.0006(syst). The limits on the possible tensor and scalar
couplings have been obtained: f(T)/f+(0)=0.021 +0.064 -0.075 (stat) +-
0.026(syst) ; f(S)/f+(0)=0.002 +0.020 -0.022 (stat) +- 0.003(syst)Comment: LaTeX-2e, epsfig.sty, 10 pages, 7 figures in EPS forma
Gluon polarization in the nucleon from quasi-real photoproduction of high-pT hadron pairs
We present a determination of the gluon polarization Delta G/G in the
nucleon, based on the helicity asymmetry of quasi-real photoproduction events,
Q^2<1(GeV/c)^2, with a pair of large transverse-momentum hadrons in the final
state. The data were obtained by the COMPASS experiment at CERN using a 160 GeV
polarized muon beam scattered on a polarized 6-LiD target. The helicity
asymmetry for the selected events is = 0.002 +- 0.019(stat.) +-
0.003(syst.). From this value, we obtain in a leading-order QCD analysis Delta
G/G=0.024 +- 0.089(stat.) +- 0.057(syst.) at x_g = 0.095 and mu^2 =~ 3
(GeV}/c)^2.Comment: 10 pages, 3 figure
The Deuteron Spin-dependent Structure Function g1d and its First Moment
We present a measurement of the deuteron spin-dependent structure function
g1d based on the data collected by the COMPASS experiment at CERN during the
years 2002-2004. The data provide an accurate evaluation for Gamma_1^d, the
first moment of g1d(x), and for the matrix element of the singlet axial
current, a0. The results of QCD fits in the next to leading order (NLO) on all
g1 deep inelastic scattering data are also presented. They provide two
solutions with the gluon spin distribution function Delta G positive or
negative, which describe the data equally well. In both cases, at Q^2 = 3
(GeV/c)^2 the first moment of Delta G is found to be of the order of 0.2 - 0.3
in absolute value.Comment: fits redone using MRST2004 instead of MRSV1998 for G(x), correlation
matrix adde
- …