14 research outputs found
Real world hospital costs following stress echocardiography in the UK: a costing study from the EVAREST/BSE-NSTEP multi-entre study
Background: Stress echocardiography is widely used to detect coronary artery disease, but little evidence on downstream hospital costs in real-world practice is available. We examined how stress echocardiography accuracy and
downstream hospital costs vary across NHS hospitals and identifed key factors that afect costs to help inform future
clinical planning and guidelines.
Methods: Data on 7636 patients recruited from 31 NHS hospitals within the UK between 2014 and 2020 as part of EVAREST/BSE-NSTEP clinical study, were used. Data included all diagnostic tests, procedures, and hospital admissions
for 12 months after a stress echocardiogram and were costed using the NHS national unit costs. A decision tree was built to illustrate the clinical pathway and estimate average downstream hospital costs. Multi-level regression analysis was performed to identify variation in accuracy and costs at both patient, procedural, and hospital level. Linear regression and extrapolation were used to estimate annual hospital cost-savings associated with increasing predictive accuracy at hospital and national level.
Results: Stress echocardiography accuracy varied with patient, hospital and operator characteristics. Hypertension, presence of wall motion abnormalities and higher number of hospital cardiology outpatient attendances annually
reduced accuracy, adjusted odds ratio of 0.78 (95% CI 0.65 to 0.93), 0.27 (95% CI 0.15 to 0.48), 0.99 (95% CI 0.98 to 0.99)
respectively, whereas a prior myocardial infarction, angiotensin receptor blocker medication, and greater operator experience increased accuracy, adjusted odds ratio of 1.77 (95% CI 1.34 to 2.33), 1.64 (95% CI 1.22 to 2.22), and 1.06 (95% CI 1.02 to 1.09) respectively. Average downstream costs were £646 per patient (SD 1796) with signifcant variation across hospitals. The average downstream costs between the 31 hospitals varied from £384–1730 per patient. False positive and false negative tests were associated with average downstream costs of £1446 (SD £601) and £4192 (SD 3332) respectively, driven by increased non-elective hospital admissions, adjusted odds ratio 2.48 (95% CI 1.08 to 5.66), 21.06 (95% CI 10.41 to 42.59) respectively. We estimated that an increase in accuracy by 1 percentage point could save the NHS in the UK £3.2 million annually.
Conclusion: This study provides real-world evidence of downstream costs associated with stress echocardiography practice in the UK and estimates how improvements in accuracy could impact healthcare expenditure in the NHS. A real-world downstream costing approach could be adopted more widely in evaluation of imaging tests and interventions to refect actual value for money and support realistic planning
Real world hospital costs following stress echocardiography in the UK: a costing study from the EVAREST/BSE-NSTEP multi-centre study
Background: Stress echocardiography is widely used to detect coronary artery disease, but little evidence on downstream hospital costs in real-world practice is available. We examined how stress echocardiography accuracy and downstream hospital costs vary across NHS hospitals and identified key factors that affect costs to help inform future clinical planning and guidelines. Methods: Data on 7636 patients recruited from 31 NHS hospitals within the UK between 2014 and 2020 as part of EVAREST/BSE-NSTEP clinical study, were used. Data included all diagnostic tests, procedures, and hospital admissions for 12 months after a stress echocardiogram and were costed using the NHS national unit costs. A decision tree was built to illustrate the clinical pathway and estimate average downstream hospital costs. Multi-level regression analysis was performed to identify variation in accuracy and costs at both patient, procedural, and hospital level. Linear regression and extrapolation were used to estimate annual hospital cost-savings associated with increasing predictive accuracy at hospital and national level. Results: Stress echocardiography accuracy varied with patient, hospital and operator characteristics. Hypertension, presence of wall motion abnormalities and higher number of hospital cardiology outpatient attendances annually reduced accuracy, adjusted odds ratio of 0.78 (95% CI 0.65 to 0.93), 0.27 (95% CI 0.15 to 0.48), 0.99 (95% CI 0.98 to 0.99) respectively, whereas a prior myocardial infarction, angiotensin receptor blocker medication, and greater operator experience increased accuracy, adjusted odds ratio of 1.77 (95% CI 1.34 to 2.33), 1.64 (95% CI 1.22 to 2.22), and 1.06 (95% CI 1.02 to 1.09) respectively. Average downstream costs were £646 per patient (SD 1796) with significant variation across hospitals. The average downstream costs between the 31 hospitals varied from £384–1730 per patient. False positive and false negative tests were associated with average downstream costs of £1446 (SD £601) and £4192 (SD 3332) respectively, driven by increased non-elective hospital admissions, adjusted odds ratio 2.48 (95% CI 1.08 to 5.66), 21.06 (95% CI 10.41 to 42.59) respectively. We estimated that an increase in accuracy by 1 percentage point could save the NHS in the UK £3.2 million annually. Conclusion: This study provides real-world evidence of downstream costs associated with stress echocardiography practice in the UK and estimates how improvements in accuracy could impact healthcare expenditure in the NHS. A real-world downstream costing approach could be adopted more widely in evaluation of imaging tests and interventions to reflect actual value for money and support realistic planning
Normal ranges of left atrial volumes and ejection fraction by 3D echocardiography in adults: a systematic review and meta-analysis
Increased sizes and dysfunction of the left atrium have been related to adverse outcomes. 3D-echocardiography is more accurate than 2D-echocardiography in estimating LA volumes and ejection fraction. However, the use of 3DE for LA analysis is limited by the absence of established reference values. We performed a systematic review and meta-analysis to provide reference ranges of LA maximum and minimum volumes indexed for body surface area (LAVi max and LAVi min, respectively), and LA-EF assessed by 3DE in healthy adults. Data search was conducted from inception through September 15, 2021, using the following Medical Subject Heading terms: left atrial/atrium, three-dimensional/3D echocardiography. The study protocol was registered in the PROSPERO database (CRD42021252428). 15 studies including 4,226 healthy adults (51% males) and reporting 3DE values of LAVi max, LAVi min and LA-EF were selected. LAVi max, LAVi min and LA-EF mean and reference values were equal to 25.18 ml/m2 (95% CI 23.10, 27.26), 11.10 ml/m2 (10.01, 12.18) and 55.94% (51.92, 59.96), respectively. No influential studies were identified. Pooled estimates per age group- and sex were also estimated. By meta-regression analyses, we identified variability in LA volumes and LA-EF depending on participants’ age, ethnicity and number of heart cycles at 3D multi-beat acquisition. At individual patient data analysis conducted on 374 subjects, a software effect on LA-EF was shown. This systematic review and meta-analysis provides reference values of LAVi max, LAVi min and LA-EF assessed by 3DE in healthy adults, encouraging 3DE evaluation of the LA evaluation in daily practice. © 2022, The Author(s), under exclusive licence to Springer Nature B.V
A 3D fibre beam-column element with shear modelling for the inelastic analysis of steel structures
A force-based fiber beam-column element is proposed for the capacity assessment of frame structures under high shear. The proposed element is suitable for the performance assessment of large scale steel structures, which are not flexure-dominated. The element formulation follows the assumptions of the Timoshenko beam theory, while its kinematics are obtained through the natural-mode method. The element state-determination phase, instead of uniaxial material laws, typically associated with fiber elements, is based on a three-dimensional law taking into consideration the interaction between axial, bending, shear and torsion. Numerical examples are presented confirming the accuracy and the computational efficiency of the proposed formulation under monotonic, cyclic and dynamic/seismic loading. Compared to experimental results and the results of detailed finite element models, excellent agreement is achieved