    Routine clinical cardiovascular magnetic resonance in paediatric and adult congenital heart disease: patients, protocols, questions asked and contributions made

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Cardiovascular Magnetic Resonance (CMR) of patients with congenital heart disease (CHD) has become routine clinical practice. However, existing CMR protocols focus predominantly on patients with ischemic heart disease, and information is limited on the types of patient with CHD who benefit from CMR investigation, and in what ways. Therefore the aim of this study was to answer the questions: What type of patients were studied by CMR in a centre specializing in paediatric and adult CHD management? What questions were asked, which protocols were used and were the questions successfully answered? To answer these questions, we conducted a cohort study of all 362 patients that received routine clinical CMR during 2007 at the Department of Paediatric Cardiology and Congenital Heart Disease at the Deutsches Herzzentrum München.</p> <p>Results</p> <p>Underlying diagnosis was in 33% Fallot's tetralogy, 17% aortic coarctation, 8% Ebstein's disease, 6% Marfan's disease, 4% single ventricle with Fontan-like circulation, and 32% others. Median age was 26 years (7 days – 75 years). Ventricular volumes were assessed in 67% of the patients; flow in 74%; unknown anatomy only in 9%; specific individual morphology of known anatomy in 83%; myocardial fibrosis in 8%; stress-induced myocardial perfusion defects in 1%. Only in 3% of the cases the question could not be fully answered.</p> <p>Conclusion</p> <p>Contrary to common belief, routine CMR of patients with CHD was not requested to address global anatomical questions so much as to clarify specific questions of morphology and function of known anatomy. The CMR protocols used differed markedly from those widely used in patients with ischemic heart disease.</p

    Performance of turbo high-pitch dual-source CT for coronary CT angiography: first ex vivo and patient experience

    Full text link
    OBJECTIVES: To evaluate image quality, maximal heart rate allowing for diagnostic imaging, and radiation dose of turbo high-pitch dual-source coronary computed tomographic angiography (CCTA). METHODS: First, a cardiac motion phantom simulating heart rates (HRs) from 60-90 bpm in 5-bpm steps was examined on a third-generation dual-source 192-slice CT (prospective ECG-triggering, pitch 3.2; rotation time, 250 ms). Subjective image quality regarding the presence of motion artefacts was interpreted by two readers on a four-point scale (1, excellent; 4, non-diagnostic). Objective image quality was assessed by calculating distortion vectors. Thereafter, 20 consecutive patients (median, 50 years) undergoing clinically indicated CCTA were included. RESULTS: In the phantom study, image quality was rated diagnostic up to the HR75 bpm, with object distortion being 1 mm or less. Distortion increased above 1 mm at HR of 80-90 bpm. Patients had a mean HR of 66 bpm (47-78 bpm). Coronary segments were of diagnostic image quality for all patients with HR up to 73 bpm. Average effective radiation dose in patients was 0.6 ± 0.3 mSv. CONCLUSIONS: Our combined phantom and patient study indicates that CCTA with turbo high-pitch third-generation dual-source 192-slice CT can be performed at HR up to 75 bpm while maintaining diagnostic image quality, being associated with an average radiation dose of 0.6 mSv. KEY POINTS: • CCTA is feasible with the turbo high-pitch mode. • Turbo high-pitch CCTA provides diagnostic image quality up to 73 bpm. • The radiation dose of high-pitch CCTA is 0.6 mSv on average
    corecore