3 research outputs found

    Array comparative genomic hybridisation (aCGH) analysis of premenopausal breast cancers from a nuclear fallout area and matched cases from Western New York

    Get PDF
    High-resolution array comparative genomic hybridisation (aCGH) analysis of DNA copy number aberrations (CNAs) was performed on breast carcinomas in premenopausal women from Western New York (WNY) and from Gomel, Belarus, an area exposed to fallout from the 1986 Chernobyl nuclear accident. Genomic DNA was isolated from 47 frozen tumour specimens from 42 patients and hybridised to arrays spotted with more than 3000 BAC clones. In all, 20 samples were from WNY and 27 were from Belarus. In total, 34 samples were primary tumours and 13 were lymph node metastases, including five matched pairs from Gomel. The average number of total CNAs per sample was 76 (range 35–134). We identified 152 CNAs (92 gains and 60 losses) occurring in more than 10% of the samples. The most common amplifications included gains at 8q13.2 (49%), at 1p21.1 (36%), and at 8q24.21 (36%). The most common deletions were at 1p36.22 (26%), at 17p13.2 (26%), and at 8p23.3 (23%). Belarussian tumours had more amplifications and fewer deletions than WNY breast cancers. HER2/neu negativity and younger age were also associated with a higher number of gains and fewer losses. In the five paired samples, we observed more discordant than concordant DNA changes. Unsupervised hierarchical cluster analysis revealed two distinct groups of tumours: one comprised predominantly of Belarussian carcinomas and the other largely consisting of WNY cases. In total, 50 CNAs occurred significantly more commonly in one cohort vs the other, and these included some candidate signature amplifications in the breast cancers in women exposed to significant radiation. In conclusion, our high-density aCGH study has revealed a large number of genetic aberrations in individual premenopausal breast cancer specimens, some of which had not been reported before. We identified a distinct CNA profile for carcinomas from a nuclear fallout area, suggesting a possible molecular fingerprint of radiation-associated breast cancer

    Структурные схемы асинхронного двигателя с короткозамкнутым ротором для частотно-регулируемого электропривода со скалярным и векторным управлением

    Get PDF
    Modern control systems for variable-frequency asynchronous electric drives (ED) are based on three-phase asynchronous motor (AM) represented by two-phase general electric machine. This simplifies mathematical description of AM and practical implementation of control systems of frequency-controlled asynchronous EDs, while the mathematical description of AM can be carried out in various coordinate systems. In practice, when studying processes in AM, mathematical description and their structural schemes are most often used in fixed coordinate system ,  rigidly connected to the stator and axis d synchronously rotating with the stator magnetic field coordinate system d, g, oriented on rotor interlinkage vector  , which greatly simplifies the study of their mathematical models. The obtained structural layouts contain internal back couplings, including nonlinear ones, resulting from the equations of the stator voltage projections. To compensate for the internal EMF of the motor induced in its stator, back couplings are used at the input of the converters, allowing to simplify the block diagrams of motors and, accordingly, the analysis of control systems. The resulting mathematical models and block diagrams of AM in a fixed coordinate system α, β and axis d synchronously rotating d, g, oriented on rotor interlinkage vector ψ , it is feasible to use in systems of frequency-controlled asynchronous EDs, respectively, with scalar and vector control . The introduction of back couplings voltages at the inlet of the converter into the system of the mentioned ED, compensating the EMF of the AM rotation, by analogy with DC motors, ensures independent control of their magnetic flux and electromagnetic moment .  The obtained mathematical models and AM block diagrams can be used for development of sensorless systems of frequency-controlled asynchronous EDs, where the motor parameters such as interlinkage, angular velocity, electromagnetic moment, etc .  are calculated from the measured values of phase current and stator voltage of electric motor .Современные системы управления частотно-регулируемых асинхронных электроприводах (ЭП) базируются на представлении трехфазного асинхронного двигателя (АД) двухфазной обобщенной электрической машиной. Это упрощает математическое описание АД и практическую реализацию систем управления частотно-регулируемых асинхронных ЭП, при этом математическое описание АД может проводится в различных системах координат. На практике при исследовании процессов в АД наиболее часто используется математическое описание и их структурные схемы в неподвижной системе координат ,  жестко связанной со статором и вращающейся синхронно с магнитным полем статора системе координат d, g осью d, ориентированной по вектору потокосцепления ротора  , что значительно упрощает исследование их математических моделей. Полученные структурные схемы содержат внутренние обратные связи, в том числе и нелинейные, вытекающие из уравнений проекций напряжений статора. Для компенсации внутренних ЭДС двигателя, наводимых в его статоре, используются обратные связи на входе преобразователей, что позволяет упростить структурные схемы двигателей, а соответственно, и анализ систем управления. Полученные математические модели и структурные схемы АД в неподвижной системе координат ,  и синхронно вращающейся d, g осью d, ориентированной по вектору потокосцепления ротора  , целесообразно использовать в системах частотно-регулируемых асинхронных ЭП, соответственно, со скалярным и векторным управлением. Введение в систему указанных ЭП напряжений обратных связей на входе преобразователя, компенсирующих ЭДС вращения АД, по аналогии с двигателями постоянного тока обеспечивает возможность независимого регулирования их магнитного потока и электромагнитного момента. Полученные математические модели и структурные схемы АД возможно использовать при разработке бездатчиковых систем частотно-регулируемых асинхронных ЭП, где по измеряемым значениям фазных токов и напряжений статора электродвигателя проводится расчет таких параметров двигателя, как потокосцепление, угловая скорость, электромагнитный момент и др
    corecore