81 research outputs found

    A new aquarium for Boston

    Get PDF
    Thesis (M.Arch.) Massachusetts Institute of Technology. Dept. of Architecture, 1953.Accompanying drawings held by MIT Museum.Includes bibliographies.by Henry A. Olko.M.Arch

    Individual monitoring for internal exposure in Europe and the integration of dosimetric data

    Get PDF
    The European Radiation Dosimetry Group, EURADOS, established a working group consisting of experts whose aim is to assist in the process of harmonisation of individual monitoring as part of the protection of occupationally exposed workers. A catalogue of facilities and internal dosimetric techniques related to individual monitoring in Europe has been completed as a result of this EURADOS study. A questionnaire was sent in 2002 to services requesting information on various topics including type of exposures, techniques used for direct and indirect measurements including calibration and sensitivity data and the methods employed for the assessment of internal doses. Information relating to Quality Control procedures for direct and indirect measurements, Quality Assurance Programmes in the facilities and legal requirements for ‘approved dosimetric services' were also considered. A total of 71 completed questionnaires were returned by internal dosimetry facilities in 26 countries. This results in an overview of the actual status of the processes used in internal exposure estimation in Europe. In many ways harmonisation is a reality in internal dose assessments, especially when taking into account the measurements of the activity retained or excreted from the body. However, a future study detailing the estimation of minimum detectable activity in the laboratories is highly recommended. Points to focus on in future harmonisation activities are as follows: the process of calculation of doses from measured activity, establishment of guidelines, similar dosimetric tools and application of the same ICRP recommendations. This would lead to a better and more harmonised approach to the estimation of internal exposures in all European facilitie

    Thermoluminescent detectors applied in individual monitoring of radiation workers in Europe—a review based on the EURADOS questionnaire

    Get PDF
    Among the activities of EURADOS Working Group 2 formed by experts from several European countries is the harmonisation of individual monitoring as part of radiation protection of occupationally exposed persons. Here, we provide information about thermoluminescent detectors (TLDs) applied by the European dosimetric services and the dosimetric characteristics of dosemeters in which these detectors are applied. Among 91 services from 29 countries which responded to the EURADOS questionnaire, 61 apply dosemeters with TLDs for the determination of personal dose equivalent Hp(10) for photons and beta radiation, and 16 services use TLDs for neutron albedo dosemeters. Those most frequently used are standard lithium fluoride TLDs (mainly TLD-100, TLD-700, Polish MTS-N and MTS-7, Russian DTG-4), high-sensitive lithium fluoride (GR-200, MCP-N) and lithium borate TLDs. Some services use calcium sulphate and calcium fluoride detectors. For neutron dosimetry, most services apply pairs of LiF:Mg,Ti TLDs with 6Li and 7Li. The characteristics (energy response) of individual dosemeters are mainly related to the energy response of the detectors and filters applied. The construction of filters in dosemeters applied for measurements of Hp(10) and their energy response are also reviewe

    Workplace monitoring for exposures to radon and to other natural sources in Europe: integration of monitoring for internal and external exposures

    Get PDF
    Part of the action of the EURADOS working group (European Radiation Dosimetry Group) on ‘Harmonisation of Individual Monitoring in Europe' was to investigate how the results from personal dosemeters for external radiation, from monitoring for internal exposure and from workplace monitoring, can be combined into a complete and consistent system of individual monitoring. To facilitate this work, the ‘EURADOS questionnaire Q3' relating to radon and other natural sources of radiation in the workplace was distributed to relevant institutes across Europe. A total of 24 countries replied to the questionnaire. This study offers an important overview on actual regulations, national standards and reference levels for protection of employees from radon and other natural sources in different workplace scenarios. Information was also collected on individual monitoring and area monitoring to determine individual doses in workplaces with elevated levels of natural radiation. The article discusses in detail the results obtained showing by country the reference level in workplaces for radon gas and other natural sources. In both instances, exposures in mines, other underground workplaces, industry workplaces/waterworks, offices, schools and day-care homes were considered. The resultant data clearly indicate that there is a need for harmonisation among countries, not least in the areas of regulation and use of reference levels in the workplac

    Analysis of time-profiles with in-beam PET monitoring in charged particle therapy

    Full text link
    Background: Treatment verification with PET imaging in charged particle therapy is conventionally done by comparing measurements of spatial distributions with Monte Carlo (MC) predictions. However, decay curves can provide additional independent information about the treatment and the irradiated tissue. Most studies performed so far focus on long time intervals. Here we investigate the reliability of MC predictions of space and time (decay rate) profiles shortly after irradiation, and we show how the decay rates can give an indication about the elements of which the phantom is made up. Methods and Materials: Various phantoms were irradiated in clinical and near-clinical conditions at the Cyclotron Centre of the Bronowice proton therapy centre. PET data were acquired with a planar 16x16 cm2^2 PET system. MC simulations of particle interactions and photon propagation in the phantoms were performed using the FLUKA code. The analysis included a comparison between experimental data and MC simulations of space and time profiles, as well as a fitting procedure to obtain the various isotope contributions in the phantoms. Results and conclusions: There was a good agreement between data and MC predictions in 1-dimensional space and decay rate distributions. The fractions of 11^{11}C, 15^{15}O and 10^{10}C that were obtained by fitting the decay rates with multiple simple exponentials generally agreed well with the MC expectations. We found a small excess of 10^{10}C in data compared to what was predicted in MC, which was clear especially in the PE phantom.Comment: 9 pages, 5 figures, 1 table. Proceedings of the 20th International Workshop on Radiation Imaging Detectors (iWorid2018), 24-28 June 2018, Sundsvall, Swede

    Individual monitoring for internal exposures in Europe: Conclusions of an EURADOS action

    Get PDF
    Once the EC Directive 96/29 has been implemented into national regulation across Europe, the coordination of dosimetry laboratories for the monitoring of occupational exposures becomes the principal aim to achieve. Within this framework the European Radiation Dosimetry Group, EURADOS, carried out an Action on ‘Harmonisation of Individual Monitoring' (2000-2004) to promote coordination in the field of individual monitoring of occupational exposures throughout Europe. With reference to internal exposures, the main aims were the completion of a catalogue of internal dosimetry services and an inventory of methods and techniques used for individual monitoring at European internal dosimetry facilities. At the end of this EURADOS Action, a report was published in Radiation Protection Dosimetry in 2004. The information collected related to various topics: the equipments used for the measurement of internal exposures, calibration and sensitivity data, the methods applied for the assessment of internal doses, Quality Control procedures, Quality Assurance Programmes in the facilities and legal requirements. The information to be presented here will give a general overview of the actual status of individual monitoring for internal exposures in Europ

    A catalogue of dosemeters and dosimetric services within Europe—an update

    Get PDF
    The catalogue of dosemeters and dosimetric services within the European Union (EU) Member States and Switzerland that was issued by EURADOS in the year 2000 has been updated and extended with information on dosimetric services in the new EU Member States and Bulgaria, Croatia, Romania, Serbia and Montenegro, and Ukraine. The total number of dosimetric services in these European countries is now estimated to be about 200. The present catalogue is based on information collected from 90 European dosimetric services, among which 34 questionnaires from 32 services were obtained over the years 2001-2004 for the first time. This article assesses and updates the present use of personal dosemeters and the extent to which occupationally exposed persons in Europe are monitored with dosemeters able to measure the operational quantity—personal dose equivalent, HP(d). The perspective of joining EU by the new countries accelerated the implementation of the EU Basic Safety Standard Directive to their national regulations. As a result, all newly investigated services reported their ability to measure HP(d). The catalogue provides information on the dosemeters, dose calculation and background subtraction algorithms, calibration methods, energy and angular response, and performanc

    Characterization of a novel proton-CT scanner based on Silicon and LaBr3_3(Ce) detectors

    Full text link
    Treatment planning systems at proton-therapy centres generally use X-ray computed tomography (CT) as primary imaging technique to infer the proton treatment doses to tumour and healthy tissues. However, proton stopping powers in the body, as derived from X-ray images, suffer from important proton-range uncertainties. In order to reduce this uncertainty in range, one could use proton-CT images instead. The main goal of this work is to test the capabilities of a newly-developed proton-CT scanner, based on the use of a set of tracking detectors and a high energy resolution scintillator for the residual energy of the protons. Different custom-made phantoms were positioned at the field of view of the scanner and were irradiated with protons at the CCB proton-therapy center in Krakow. We measured with the phantoms at different angles and produced sinograms that were used to obtain reconstructed images by Filtered Back-Projection (FBP). The obtained images were used to determine the capabilities of our scanner in terms of spatial resolution and proton Relative Stopping Power mapping and validate its use as proton-CT scanner. The results show that the scanner can produce medium-high quality images, with spatial resolution better than 2 mm in radiography, below 3 mm in tomography and resolving power in the RSP comparable to other state of the art pCT cameras

    Proton radiographs using position-sensitive silicon detectors and high-resolution scintillators

    Full text link
    Proton therapy is a cancer treatment technique currently in growth worldwide. It offers advantages with respect to conventional X-ray and γ\gamma-ray radiotherapy, in particular, a better control of the dose deposition allowing to reach a higher conformity in the treatments. Therefore, it causes less damage to the surrounding healthy tissue and less secondary effects. However, in order to take full advantage of its potential, improvements in treatment planning and dose verification are required. A new prototype of proton Computed Tomography scanner is proposed to design more accurate and precise treatment plans for proton therapy. Here, results obtained from an experiment performed using a 100-MeV proton beam at the CCB facility in Krakow (Poland) are presented. Proton radiographs of PMMA samples of 50-mm thickness with spatial patterns in aluminum were taken. Their properties were studied, including reproduction of the dimensions, spatial resolution and sensitivity to different materials. They demonstrate the capabilities of the system to produce images with protons. Structures of up to 2 mm are nicely resolved and the sensitivity of the system was enough to distinguish thicknesses of 10 mm of aluminum or PMMA. This constitutes a first step to validate the device as a proton radiography scanner previous to the future tests as a proton CT scanner.Comment: 7 pages, 11 figures, submitted to IEEE TNS ANIMMA 2021 Conference Proceeding

    Monitoring Proton Therapy Through In-Beam PET: An Experimental Phantom Study

    Get PDF
    In this paper, we investigate the use of a positron emission tomography (PET) system to monitor the proton therapy. The monitoring procedure is based on the comparison between the β+ activity generated in the irradiated volume during the treatment, with the β+ activity distribution obtained with Monte Carlo (MC) simulation. The dedicated PET system is a dual head detection system; each head is composed of nine scintillating LYSO crystal matrices read out independently with a custom modularized acquisition system. Our experimental data were acquired at the Cyclotron Centre Bronowice, Institute Nuclear Physics in Kraków, Poland, and were simulated with the FLUKA MC code. Homogeneous and heterogeneous plastic phantoms were irradiated with monoenergetic 130 MeV protons. The capabilities of our PET system to distinguish different irradiated materials were investigated, and the proton pencil-beams were used as probes. Our focus was to analyze the activity width and the total activity event number in several cases. Irradiations were performed using either single pencil-beams one at a time, or two pencil-beams during the same data taking. The comparison of 1-D activity profile for experimental data and MC simulation were always in good agreement showing that, the treatment quality assessment in proton therapy can be based on β+ activity measurements
    • …
    corecore