1,055 research outputs found
Age and geographic dependence of Zika virus infection during the outbreak on Yap island, 2007.
Intensive surveillance of Zika virus infection conducted on Yap Island has provided crucial information on the epidemiological characteristics of the virus, but the rate of infection and medical attendance stratified by age and geographical location of the epidemic have yet to be fully clarified. In the present study, we reanalyzed surveillance data reported in a previous study. Likelihood-based Bayesian inference was used to gauge the age and geographically dependent force of infection and age-dependent reporting rate, with unobservable variables imputed by the data augmentation method. The inferred age-dependent component of the force of infection was suggested to be up to 3-4 times higher among older adults than among children. The age-dependent reporting rate ranged from 0.7% (5-9 years old) to 3.3% (50-54 years old). The proportion of serologically confirmed cases among total probable or confirmed cases was estimated to be 44.9%. The cumulative incidence of infection varied by municipality: Median values were over 80% in multiple locations (Gagil, Tomil, and Weloy), but relatively low values (below 50%) were derived in other locations. However, the possibility of a comparably high incidence of infection was not excluded even in municipalities with the lowest estimates. The results suggested a high degree of heterogeneity in the Yap epidemic. The force of infection and reporting rate were higher among older age groups, and this discrepancy implied that the demographic patterns were remarkably different between all infected and medically attended individuals. A higher reporting rate may have reflected more severe clinical presentation among adults. The symptomatic ratio in dengue cases is known to correlate with age, and our findings presumably indicate a similar tendency in Zika virus disease
Quark Mass Matrices with Four and Five Texture Zeroes, and the CKM Matrix, in terms of Mass Eigenvalues
Using the triangular matrix techniques of Kuo et al and Chiu et al for the
four and five texture zero cases, with vanishing (11) elements for U and D
matrices, it is shown, from the general eigenvalue equations and hierarchy
conditions, that the quark mass matrices, and the CKM matrix can be expressed
(except for the phases) entirely in terms of quark masses. The matrix
structures are then quite simple and transparent. We confirm their results for
the five texture zero case but find, upon closer examination of all the CKM
elements which our results provide, that six of their nine patterns for the
four texture zero case are not compatible with experiments. In total, only one
five-texture zero and three four-texture zero patterns are allowed.Comment: 15 pages, 3 table
Spatial Resolution of the Heavy Ion Beam Probe on LHD
he sizes of sample volumes, which determine the spatial resolution, are estimated by trajectory calculation for the heavy ion beam probe on LHD. The beam width, the divergence, and the beam energy difference are taken into account. From the points of view of the spatial resolution and the signal intensity, parallel beam is suitable for the injection beam. The size of the sample volume by the parallel beam with 10mm diameter is 42 mm. It is sufficient to measure the potential profile in the internal transport barrier in the LHD plasma. Taking into account the spatial profile of the beam, the spatial resolution will be better than 42 mm
Potential measurements with heavy ion beam probe system on LHD
The heavy ion beam probe system in the Large Helical Device (LHD) was improved as follows. At first, the additional new sweeper was installed into the diagnostic port to extend the observable region. By using this sweeper, the potential profile was measured in a wider minor radius range than in previous experiments, in the case of outward shifted magnetic configuration of LHD. Next, the real time control system was installed to control the probe beam orbit for measuring the potential in plasma with large plasma current. In this system, a digital signal processor was used to control the probe beam in real time. The system worked well in the fixed position observation mode. In the sweeping mode for profile measurement, this control system became unstable. The details of this system and the experimental results are reported in this article
- …