11 research outputs found

    Impact of a novel surgical wound protection device on observed versus expected surgical site infection rates after colectomy using the National Surgical Quality Improvement Program Risk Calculator

    Get PDF
    Surgical site infection (SSI) remains a persistent and morbid problem in colorectal surgery. A novel surgical device that combines barrier surgical wound protection and continuous surgical wound irrigation was evaluated in a cohort of elective colorectal surgery patients. A retrospective analysis was performed comparing rates of SSI observed in a prospective cohort study with the predicted rate of SSI using the American College of Surgeons (ACS) National Surgical Quality Improvement Program (NSQIP) Risk Calculator.A prospective multi-center study of colectomy patients was conducted using a study device for surgical site retraction and protection, as well as irrigation of the incision. Patients were followed for 30 days after the surgical procedure to assess for SSI. After completion of the study, patients' characteristics were inserted into the ACS-NSQIP Risk Calculator to determine the predicted rate of SSI for the given patient population and compared with the observed rate in the study.A total of 108 subjects were enrolled in the study. The observed rate of SSI in the prospective study using the novel device was 3.7% (4/108). The predicted rate of SSI in the same patient population utilizing the ACS-NSQIP Risk Calculator was estimated to be 9.5%. This demonstrated a 61% difference (3.7% vs. 9.5%, p = 0.04) in SSI from the NSQIP predicted rate with the use of the irrigating surgical wound protection and retraction device.These data suggest the use of a novel surgical wound protection device seems to reduce the rate of SSIs in colorectal surgery

    A novel wound retractor combining continuous irrigation and barrier protection reduces incisional contamination in colorectal surgery

    No full text
    Surgical site infection (SSI) remains a persistent and morbid problem in colorectal surgery. Key to its pathogenesis is the degree of intraoperative bacterial contamination at the surgical site. The purpose of this study was to evaluate a novel wound retractor at reducing bacterial contamination.A prospective multicenter pilot study utilizing a novel wound retractor combining continuous irrigation and barrier protection was conducted in patients undergoing elective colorectal resections. Culture swabs were collected from the incision edge prior to device placement and from the exposed and protected incision edge prior to device removal. The primary and secondary endpoints were the rate of enteric and overall bacterial contamination on the exposed incision edge as compared to the protected incision edge, respectively. The safety endpoint was the absence of serious device-related adverse events.A total of 86 patients were eligible for analysis. The novel wound retractor was associated with a 66% reduction in overall bacterial contamination at the protected incision edge compared to the exposed incision edge (11.9 vs. 34.5%, P
    corecore