29 research outputs found

    Effect of gastric freezing on the electrolyes in the serum

    No full text
    의학과/석사[한글] [영문] There has been much fundamental investigation upon hypothermia in recent years and most of the experiments have been concerned with methods of cooling, reduction of temperature to lower levels than previously obtained, and the immediate metabolic effects of the cooling and rewarming process. The majority of these concern themselves with patients subjected to general hypothermia. Its used in the treatment of cancer was first described by Smith and Fay in 1939 - 1940, when patients were maintained at rectal temperature levels of 29 - 32℃. for as long as five days. Dill and Forbes and Talbot reported on schizophrenic patients subjected to hypothermia up to 60 hours, and Khalil and reported lowering of the body temperature by cooling the stomach in 1954. Since Wangensteen and associates earlest paper on physiological gastrectomy through gastric freezing, there has been considerable controversy with regard to the efficacy of the freezing in the reduction of gastric acidity. The altoration in the electrolytes during hypothermia is another sphere of conjecture and there are differences in the experimental findings. With such historical packground. experimental studies on the effect of gastric freezing on the electrolytes in the serum - K**+, Na**+, Cl**- were carried out on adult mongrel dogs. Fifteen adult mongrel dogs of both sexes weighing from 12 kg. to 22 kg. were fasted for 12 hours before the gastric freezing and they were subjected to gastric freezing under general anesthesia with penthotal sodium (30 mg./kg.). The gastric freezing was maintained for 50 minutes, and the electrolytes in serum (K**+, Na**+, Cl**-) were determined before the freezing, at the end of the freezing, 12 hours and 24 hours after the freezing, respectively. The results are as follows and there were no significant changes in the serum levels of K**+, Na**+, Cl**-, before and after the gastric freezing. 1. Sodium levels in the serum were 140 ± 1.3 mEq./L. before gastric freezing, and 141.7 ± 1.4, 141.3 ± 1.3, 143.1 ± 1.5 in 50 minutes, 12 hours, and 24 hours after gastric freezing respectively. 2. Potassium levels in the serum were 4.2 ± 0.09 mEq./L. (mean ± S.E.) before gastric freezing, and 4.0 ± 0.15, 4.2 ± 0.1, 4.1 ± 0.16 in 50 minutes, 12 hours, and 24 hours after gastric freezing respectively. 3. Chloride levels in the serum were 106.1 ± 1.1 mEq./L. (mean ± S.E.) before gastric freezing and 106.3 ± 1.0, 106.1 ± 1.2, 106.0 ± 0.9 in 50 minutes, 12 hours, and 24 hours after gastric freezing respectively.restrictio

    중앙값을 움직인 부호를 바탕으로 한 비모수 검파기

    No full text
    학위논문(석사) - 한국과학기술원 : 전기및전자공학과, 1997.2, [ v, 42 p. ]In this thesis, we propose a new detector based on the median-shift sign. We call it the median-shift sign (MSS) detector, which is an extension of the classical sign detector. We also show some properties of the optimum median -shift values. We first analyze the problem of detecting a dc signal in noise of known probability density function (pdf). The MSS detector with the optimum median-shift value, the optimum MSS detector, performs slightly better than the sign detector in Gaussian noise: it has the best performance among the detectors compared in Laplacian and Cauchy noise. It is shown that the MSS detectors with constant median-shift values are nearly equal to the optimum MSS detector. We also analyze the problem of detecting a dc signal when only partial information is available on the noise. In this case, the MSS detectors with constant median-shift values are used. The MSS detectors are almost equal to the sign detector in Gaussian noise:they perform better than the sign and Wilcoxon detectors for most signal ranges in Laplacian and Cauchy noise. Because the false alarm rate of the MSS detector is constant, the MSS detector is a nonparametric detector. The MSS detectors with small constant median-shift values have simple structure and perform better than the sign and Wilcoxon detectors for most signal ranges in non-Gaussian noise.한국과학기술원 : 전기및전자공학과
    corecore