랜덤 포리스트를 이용한 비제어 급성 출혈성 쇼크의 흰쥐에서의 생존 예측
Hemorrhagic shock is a primary cause of deaths resulting from injury in the world. Although many studies have tried to diagnose accurately hemorrhagic shock in the early stage, such attempts were not successful due to compensatory mechanisms of humans. The objective of this study was to construct a survival prediction model of rats in acute hemorrhagic shock using a random forest (RF) model. Heart rate (HR), mean arterial pressure (MAP), respiration rate (RR), lactate concentration (LC), and peripheral perfusion (PP) measured in rats were used as input variables for the RF model and its performance was compared with that of a logistic regression (LR) model. Before constructing the models, we performed 5-fold cross validation for RF variable selection, and forward stepwise variable selection for the LR model to examine which variables were important for the models. For the LR model, sensitivity, specificity, accuracy, and area under the receiver operating characteristic curve (ROC-AUC) were 0.83, 0.95, 0.88, and 0.96, respectively. For the RF models, sensitivity, specificity, accuracy, and AUC were 0.97, 0.95, 0.96, and 0.99, respectively. In conclusion, the RF model was superior to the LR model for survival prediction in the rat model.ope
Tracking a Walking Motion Based on Dynamics Using a Monocular Camera
Gait analysis is an examination which extracts objective information from observing human gait and assesses the
function. The equipments used recently for gait analysis are expensive due to multiple cameras and force plates, and
require the large space to set up the system. In this paper, we proposed a method to measure human gait motions in 3D
from a monocular video. Our approach was based on particle filtering to track human motion without training data and
previous information about a gait. We used dynamics to make physics-based motions with the consideration of contacts
between feet and base. In a walking sequence, our approach showed the mean angular error of 12.4° over all joints, which
was much smaller than the error of 34.6° with the conventional particle filter. These results showed that a monocular
camera is able to replace the existing complicated system for measuring human gait quantitatively.ope
Effects of radiation emitted by WCDMA mobile phones on electromagnetic hypersensitive subjects.
BACKGROUND: With the use of the third generation (3 G) mobile phones on the rise, social concerns have arisen concerning the possible health effects of radio frequency-electromagnetic fields (RF-EMFs) emitted by wideband code division multiple access (WCDMA) mobile phones in humans. The number of people with self-reported electromagnetic hypersensitivity (EHS), who complain of various subjective symptoms such as headache, dizziness and fatigue, has also increased. However, the origins of EHS remain unclear.
METHODS: In this double-blind study, two volunteer groups of 17 EHS and 20 non-EHS subjects were simultaneously investigated for physiological changes (heart rate, heart rate variability, and respiration rate), eight subjective symptoms, and perception of RF-EMFs during real and sham exposure sessions. Experiments were conducted using a dummy phone containing a WCDMA module (average power, 24 dBm at 1950 MHz; specific absorption rate, 1.57 W/kg) within a headset placed on the head for 32 min.
RESULTS: WCDMA RF-EMFs generated no physiological changes or subjective symptoms in either group. There was no evidence that EHS subjects perceived RF-EMFs better than non-EHS subjects.
CONCLUSIONS: Considering the analyzed physiological data, the subjective symptoms surveyed, and the percentages of those who believed they were being exposed, 32 min of RF radiation emitted by WCDMA mobile phones demonstrated no effects in either EHS or non-EHS subjects.ope
젖산 농도와 관류 비를 이용한 흰쥐에서의 출혈성 쇼크의 사망 예측 지표 개발
Purpose: We proposed a new index for predicting death resulting from hemorrhagic shock, which was calculated by dividing measured lactate concentration by perfusion. Methods: Using 24 Sprague-Dawley (S-D) rats, we induced uncontrolled hemorrhage and then measured blood lactate concentration and perfusion in addition to vital signs such as heart rate, blood pressure, respiration rate and temperature. Perfusion and lactate concentration were measured by laser Doppler flowmetry and a lactate concentration meter, respectively. We collected the data for 15 min, which consisted of 3 intervals after homeostasis, and thus obtained a new index. Results: The proposed index revealed an earlier death prediction than lactate concentration alone with the same timing as perfusion. The new index showed generally better sensitivity, specificity and accuracy than lactate concentration and perfusion. Using a receiver operating characteristic curve method, the mortality prediction with the proposed index resulted in a sensitivity of 98.0%, specificity of 90.0%, and accuracy of 93.7%. The mortality prediction with the proposed index resulted in a sensitivity of 98.0%, specificity of 90.0% and accuracy of 93.7%. Conclusion: This index could provide physicians, in emergency situations, with early and accurate mortality predictions for cases of human hemorrhagic shock.ope
Effects of 60 Hz magnetic fields on teenagers and adults
BACKGROUND:
As use of electrical devices has increased, social concerns about the possible effects of 60 Hz electromagnetic fields on human health have increased. Accordingly, the number of people who complain of various symptoms such as headache and insomnia has risen. Many previous studies of the effects of extremely low frequency (ELF) magnetic field exposure on children have focused on the occurrence of childhood leukaemia and central nervous system cancers. However, very few provocation studies have examined the health effects of ELF magnetic fields on teenagers.
METHODS:
In this double-blind study, we simultaneously investigated physiological changes (heart rate, respiration rate, and heart rate variability), subjective symptoms, and magnetic field perception to determine the reliable effects of 60 Hz 12.5 μT magnetic fields on teenagers. Two volunteer groups of 30 adults and 30 teenagers were tested with exposure to sham and real magnetic fields for 32 min.
RESULTS:
ELF magnetic field exposure did not have any effects on the physiological parameters or eight subjective symptoms in either group. Neither group correctly perceived the magnetic fields.
CONCLUSIONS:
Physiological data were analysed, subjective symptoms surveyed, and the percentages of those who believed they were being exposed were measured. No effects were observed in adults or teenagers resulting from 32 min of 60 Hz 12.5 μT magnetic field exposure.ope
Survival Prediction of Rats with Hemorrhagic Shocks Using Support Vector Machine
Hemorrhagic shock is a common cause of death in emergency rooms. Early diagnosis of hemorrhagic shock makes it possible for physicians to treat patients successfully. Therefore, the purpose of this study was to select an optimal survival prediction model using physiological parameters for the two analyzed periods: two and five minutes before and after the bleeding end. We obtained heart rates, mean arterial pressures, respiration rates and temperatures from 45 rats. These physiological parameters were used for the training and testing data sets of survival prediction models using an artificial neural network (ANN) and support vector machine (SVM). We applied a 5-fold cross validation method to avoid over-fitting and to select the optimal survival prediction model. In conclusion, SVM model showed slightly better accuracy than ANN model for survival prediction during the entire analysis period.ope
Increased fragility fracture risk in Korean women who snore: a 10-year population-based prospective cohort study
BACKGROUND: Snoring is frequently associated with obstructive sleep apnea (OSA). Previous studies have shown that bone mineral density was significantly lower in patients with OSA than in controls; however, these studies did not focus on fractures. Fragility fractures can lead to long-term disabilities and a decrease in quality of life. The present study aimed to investigate the association between snoring and fragility fractures.
METHODS: This study included 2969 men and 3220 women aged 40 years and older from the Ansung and Ansan cohort studies in Korea. During a 10-year follow-up period, 129 and 273 fracture cases were reported in men and women, respectively.
RESULTS: Severe snoring (6-7 nights per week or sleep disturbance by snoring in the next room) was a statistically significant risk factor for fracture (p = 0.006, hazard ratio 1.68, 95% confidence interval 1.16-2.43) after adjusting for covariates related to fragility fracture in women. However, both snoring and severe snoring groups did not show significant associations with the fracture risk in men.
CONCLUSIONS: Thus, information on the frequency of snoring in women may improve the accuracy of fragility fracture risk prediction, which can help in deciding whether intervention or treatment is necessary.ope
Effects of Radio Frequency Electromagnetic Fields Emitted by WCDMA Mobile Phones on Pacemakers and ICDs
Reports show that global system for mobile communication (GSM) mobile phones, or two-generation (2G) mobile phones, could affect functions of pacemakers and implantable cardioverter defibrillators (ICDs). In this study, we evaluated the effects of radio frequency electromagnetic fields (RF-EMFs) emitted by wideband code division multiple access (WCDMA) mobile phones, which were third-generation (3G) mobile phones, on pacemakers and ICDs. Five pacemakers and three ICDs were subjected to in-vitro test using a ECG simulator. We used a WCDMA module (average power : 0.25 W, frequency band : 1950 MHz) instead of a real WCDMA mobile phone. To assess the effects of the WCDMA module on pacemakers and ICDs, each implantable device was placed in close proximity (within 3 mm) to the WCDMA module for 5 min. As a result, no effects were observed on the five pacemakers and three ICDs for the RF-EMFs emitted by the WCDMA module. Because WCDMA mobile phones have the higher frequency band (1800-2200 MHz) and lower power output (0.01-0.25 W) than GSM moboile phone, the RF-EMFs emitted by WCDMA mobile phones do not affect patients with pacemaker or ICD.ope
Simple Scoring System and Artificial Neural Network for Knee Osteoarthritis Risk Prediction: A Cross-Sectional Study
BACKGROUND: Knee osteoarthritis (OA) is the most common joint disease of adults worldwide. Since the treatments for advanced radiographic knee OA are limited, clinicians face a significant challenge of identifying patients who are at high risk of OA in a timely and appropriate way. Therefore, we developed a simple self-assessment scoring system and an improved artificial neural network (ANN) model for knee OA.
METHODS: The Fifth Korea National Health and Nutrition Examination Surveys (KNHANES V-1) data were used to develop a scoring system and ANN for radiographic knee OA. A logistic regression analysis was used to determine the predictors of the scoring system. The ANN was constructed using 1777 participants and validated internally on 888 participants in the KNHANES V-1. The predictors of the scoring system were selected as the inputs of the ANN. External validation was performed using 4731 participants in the Osteoarthritis Initiative (OAI). Area under the curve (AUC) of the receiver operating characteristic was calculated to compare the prediction models.
RESULTS: The scoring system and ANN were built using the independent predictors including sex, age, body mass index, educational status, hypertension, moderate physical activity, and knee pain. In the internal validation, both scoring system and ANN predicted radiographic knee OA (AUC 0.73 versus 0.81, p<0.001) and symptomatic knee OA (AUC 0.88 versus 0.94, p<0.001) with good discriminative ability. In the external validation, both scoring system and ANN showed lower discriminative ability in predicting radiographic knee OA (AUC 0.62 versus 0.67, p<0.001) and symptomatic knee OA (AUC 0.70 versus 0.76, p<0.001).
CONCLUSIONS: The self-assessment scoring system may be useful for identifying the adults at high risk for knee OA. The performance of the scoring system is improved significantly by the ANN. We provided an ANN calculator to simply predict the knee OA risk.ope
Screening for Prediabetes Using Machine Learning Models
The global prevalence of diabetes is rapidly increasing. Studies support the necessity of screening and interventions for prediabetes, which could result in serious complications and diabetes. This study aimed at developing an intelligence-based screening model for prediabetes. Data from the Korean National Health and Nutrition Examination Survey (KNHANES) were used, excluding subjects with diabetes. The KNHANES 2010 data (n = 4685) were used for training and internal validation, while data from KNHANES 2011 (n = 4566) were used for external validation. We developed two models to screen for prediabetes using an artificial neural network (ANN) and support vector machine (SVM) and performed a systematic evaluation of the models using internal and external validation. We compared the performance of our models with that of a screening score model based on logistic regression analysis for prediabetes that had been developed previously. The SVM model showed the areas under the curve of 0.731 in the external datasets, which is higher than those of the ANN model (0.729) and the screening score model (0.712), respectively. The prescreening methods developed in this study performed better than the screening score model that had been developed previously and may be more effective method for prediabetes screening.ope
- …