30 research outputs found

    有限公司治理研究

    Get PDF
    本文在中国的制度背景下,以大量的实践观察为基础,本着理论与实践相结合的基本原则,研究了中国有限公司治理问题。本文认为,有限公司的基本合作关系表现为股东与股东以及股东整体与经营者(经理人)的合作关系。相应地,本文将有限公司治理问题的研究框架界定为:有限公司的股东、有限公司基本治理机构设置及其责权分布、有限公司背景下人力资本的确认与计量三个主要方面,全文由五章组成。 第一章,前言。本章说明了本文的研究动机、研究目的,界定了研究对象和研究框架,交代了研究方法。 第二章,有限公司股东。本章阐述了公司法人财产权与股东权益问题,认为出资人向公司法人让渡出资财产的所有权是公司制的本质也是公司治理的起源。...The main topic of the dissertation is the corporate governance of limited liability company(LLC)in China based on a substantial observation by the author. The author holds that the basic relationship within the LLC is the cooperation among the shareholders as well as between managers and shareholders. The research framework is constructed into 3 parts: 1.The shareholders of the LLC. 2.The basic go...学位:管理学博士院系专业:管理学院会计系_会计学学号:B20001100

    中国企业赴美上市法律和会计问题初探

    Get PDF
    本文分三部份对中国企业赴美上市的法律和会计问题进行探讨:第一部份介绍中国企业赴美上市的相关背景;第二部份探讨中国企业赴美上市的法律问题;第三部份探讨中国企业赴美上市的会计问题。 中国企业赴美上市应同时遵守中美两国的有关法律,因此本文第一部份介绍中美两国对中国企业赴美上市的相关法律规定,为进一步探讨中国企业赴美上市的法律和会计问题奠定背景基础。首先,以《公司法》、《证券法》、《国务院关于股份有限公司境外募集股份及上市的特别规定》、《到境外上市公司章程必备条款》、《国务院关于进一步加强在境外发行股票和上市管理的通知》以及国务院有关部委发布的相关配套规定为基础对涉及赴美上市的有关规定进行分析,同时...学位:管理学硕士院系专业:管理学院企业管理系_工商管理硕士(MBA)学号:19971502

    细胞角蛋白19片段抗原21-1含量化学发光微粒子定量免疫检测方法的建立

    Get PDF
    目的建立细胞角蛋白19片段抗原21-1(cytokeratin 19 fragment 21-1,CYFRA21-1,简称CY21-1)含量的化学发光微粒子免疫检测方法(chemiluminescent microparticle immunoassay,CMIA)。方法原核表达制备重组CY21-1(r CY21-1),用其免疫BALB/c小鼠后,收集小鼠脾脏细胞,常规杂交瘤技术与Sp2/0进行融合,制备CY21-1单抗。间接ELISA法筛选可稳定分泌CY21-1抗体的杂交瘤细胞,分别标记微性磁珠(magnetic beads,MB)和吖啶酯(acridinium ester,AE),筛选可特异检测CY21-1的单抗配对,建立CY21-1 CMIA,同时验证方法的线性及灵敏度,并与同类试剂盒进行比较。结果经筛选获得了一组能特异检测CY21-1的单抗配对MB*26B5-3E4*AE,建立的CY21-1 CMIA对检测CY21-1校准品的线性范围为0.1~1 000 ng/m L,R~2=0.992 3,检测灵敏度为0.076 ng/m L。该方法与美国雅培公司生产的Abbott CY21-1 CMIA诊断试剂盒平行检测250份临床血清标本的结果具有良好的相关性(R~2=0.961 6)。结论成功建立了CY21-1 CMIA,且具有良好的线性及灵敏度,为我国肺癌的临床筛查和早期诊断奠定了基础。福建省科技重大专项(2015Y0051,2011YZ0002-1);;厦门市科技计划项目(3502Z20120008

    尿碘自动分析装置的研制

    Get PDF
    国家“九五”医学科技攻关基金资助!(96-906-04-01

    Development of detection kit for T cell infected with Mycobacterium tuberculosis based on fullautomatic chemiluminescence immune analyzer

    Get PDF
    目的建立基于化学发光平台的人结核感染T细胞检测方法。方法将一株γ-干扰素单抗标记在磁微粒上,另一株γ-干扰素单抗标记在吖啶酯上,然后将检测体系与已有的细胞刺激培养体系相结合。结果本研究成功建立基于化学发光平台的人结核感染T细胞检测方法。以ElISA平台检测试剂的检测结果作为参考,该方法的灵敏度为98.3%,特异性为99.2%,总体符合率达到98.8%。结论该方法具有更高的分析灵敏度(可达0.27 Pg/M l)、更宽的线性范围(1 Pg/M l~5 000 Pg/M l)、更好的重复性(批内与批间变异系数均<6.0%)及更易实现高通量检测,为临床诊断结核感染提供了有力的工具。Objective To develop the detection kit for T cell infected with Mycobacterium tuberculosis based on full-automatic chemiluminescence immune analyzer.Mehtods An anti IFN-γ Mab was coated on the surface of microparticle.Another anti IFN-γ Mab was labelled to acridinium ester.After that, the detection system was combined with the in vitro cell culture system.Results This research developed the detection kit for T cell infected with Mycobacterium tuberculosis based on full-automatic chemiluminescence immune analyzer.Compared with the testing results of the ELISA kit, the sensitivity, specificity and total matching ratio of the CLIA kit was 98.3%, 99.2% and 98.8%, respectively.Conclusion The CLIA kit has better sensitivity(0.27 pg/m L), wilder linear range(1 pg/m L ~ 5 000 pg/m L), and better repeatability(intra and inter coefficient of variation < 6.0%).It makes a high throughput detection available.It will contribute to the clinical diagnosis of Mycobacterium tuberculosis.国家高技术研究发展计划(863计划)(2011AA02A101

    Characteristics of the interface of a laser-quenched steel substrate and chromium electroplate

    Get PDF
    The interface of a laser-discrete-quenched steel substrate and as-deposited chromium electroplate was investigated by ion beam etching, dissolving-substrate-away and using a Vickers microhardness tester, in an attempt to reveal the mechanism that the service life of the chromium-coated parts is increased by the duplex technique of laser pre-quenching plus chromium post-depositing. The laser quenching of the steel substrate can reduce the steep hardness gradient at the substrate/chromium interface and improve the load-bearing capacity of chromium electroplate. Moreover, the laser quenching prior to plating has an extremely great effect on the morphologies and microstructure of the substrate/chromium interface: there is a transient interlayer at the original substrate/chromium interface while there is not at the laser-quenchedzone/chromium interface; the near-substrate surface microstructure and morphologies of the free-standing chromium electrodeposits, whose substrate was dissolved away with nital 30% in volume, inherit the periodically gradient characteristics of the laser-discrete-quenched substrate surface. (c) 2006 Elsevier B.V. All rights reserved

    关于有限公司治理研究若干问题的探讨

    No full text
    有限公司治理应作为独立的领域加以研究,股东与股东、股东与经理人的关系处理是有限公司治理的核心,股东、治理机构设

    尿碘在线消化—流动注射催化光度测定法

    No full text
    采用流动注射分析技术与砷铈催化光度法测碘结合,选择了尿液直接进样以kMnO4-k2Cr2O7-H2SO4消化液在线消化快速准确测定尿碘的条件,建立了尿碘在线消化-流动注射催化光度分析法。方法设备简单价廉易推广,仪器操作简便易掌握,消除干扰能力强,检测范围宽,直接进尿样可测碘5~1000μg/l,连续测定变异系数<2%,平均回收率为99.3%,尿标准样测定值与给定值相对误差—1.0%,与碱灰化砷铈法对照测定,统计学检验两法之间无系统误差,分析速度70个样/H,可实现尿碘自动化快速分析,本研究结果为碘缺乏病防治尿碘监测提供了一种准确方法和有力工具。福建省卫生厅青年科学研究基

    尿中微量碘的自动分析法——流动注射分析

    No full text
    碘缺乏病(Idd)分布广泛,受缺碘威胁人口数约10亿,人群尿碘水平是划分Idd病区及评价补碘防治效果的指标之一,故尿碘监测是项长期的工作。目前国内尿碘监测采用手工碱灰化法和酸消化法,操作繁琐,误差因素多。国外的尿碘自动酸消化分析法分析速度为50个样/d,其消化系统需要浓酸高温且尿样消化后需做稀释测定,操作不便,分析速度低,而且仪器昂贵。简化尿碘检验操作程序,提高分析速度和准确度,实现自动化,降低仪器费用,已成为目前尿碘分析法的发展趋势。本文设计的尿碘自动分析系统,建立了尿碘自动分析法——尿碘在线消化—流动注射催化光度测定法,方法精密度、准确度和分析速度均获得了满意的效果,并已文献报告,本文对尿碘自动分析技术作进一步介绍。福建省卫生厅青年科学研究基金资助项
    corecore