52 research outputs found
Detection of hepatitis B virus markers using a biosensor based on imaging ellipsometry
A biosensor based on imaging ellipsometry (BIE) has been developed and validated in 169 patients for detecting five markers of hepatitis B virus (HBV) infection. The methodology has been established to pave the way for clinical diagnosis, including ligand screening, determination of the sensitivity, set-up of cut-off values (CoVs) and comparison with other clinical methods. A matrix assay method was established for ligand screening. The CoVs of HBV markers were derived with the help of receiver operating characteristic curves. Enzyme-linked immunosorbent assay (ELISA) was the reference method. Ligands with high bioactivity were selected and sensitivities of 1 ng/mL and 1 IU/mL for hepatitis B surface antigen (HBsAg) and surface antibody (anti-HBs) were obtained respectively. The CoVs of HBsAg, anti-HBs, hepatitis B e antigen, hepatitis B e antibody and core antibody were as follows: 15%, 18%, 15%, 20% and 15%, respectively, which were the percentages over the values of corresponding ligand controls. BIE can simultaneously detect up to five markers within 1 h with results in acceptable agreement with ELISA, and thus shows a potential for diagnosing hepatitis B with high throughput
Rotating compensator sampling for spectroscopic imaging ellipsometry
In this work, a rotating compensator sampling for spectroscopic imaging ellipsometry (SIE) is presented and demonstrated by characterization of a SiO(2) nanofilm pattern on Si substrate. Experiment results within spectrum of 400-700 nm show that the rotating compensator sampling is valid for SIE to obtain the ellipsometric angle distributions psi (x, y, lambda) and Delta (x, y, lambda) over the thin film pattern, the sampling times of psi (x, y) and Delta (x, y) with 576 x 768 pixels under each wavelength is less than 8 s, the precision of fitting thickness of SiO(2) is about 0.2 nm and the lateral resolution is 60.9 mu m x 24.6 mu m in the parallel and perpendicular direction with respect to the incident plane. (C) 2010 Elsevier B.V. All rights reserved
物面与光轴成倾斜夹角时进行角度自动调焦的成像系统
本实用新型涉及一种物面与光轴成倾斜夹角时进行角度自动调焦的成像系统,它包括:一像接收装置和至少一块成像透镜,该成像透镜安置在目标物和像接收装置光路中;还包括驱动和控制装置和图像分析处理系统;其中像接收装置的像敏面几何中心通过由成像透镜确定的光轴,并处于与物面上对应物点共轭的轴向位置;像接收装置通过电连接到图像分析处理系统;图像分析处理系统通过电缆与驱动和控制装置电连接。本实用新型提供的光学成像系统的角度自动调焦系统是针对物面与光轴成一倾斜夹角(0°<θ≤90°)的光学成像系统,弥补了轴向调焦装置和方法只能达到像面上局部聚焦的不足,从而达到调焦时像面整体清晰的效果。本实用新型的装置结构简单,易于调节
采用旋转补偿器积分采样的椭偏成像装置
本实用新型涉及一种采用旋转补偿器和时间积分采样的椭偏成像装置。所述装置包括:入射单元;出射单元;数据采集处理单元;数据采集处理单元通过硬触发的方式来触发出射单元获得样品的椭偏图像。本实用新型利用时间积分方法进行采样大幅度提高了系统的时间分辨率,即减少了采样时间;采用匀速旋转相位补偿器达到了稳定的目的,能够保证操控精度
采用旋转补偿器积分采样的椭偏成像方法和装置
本发明涉及一种采用旋转补偿器和时间积分采样的椭偏成像方法和装置。所述方法包括如下步骤:对系统进行设置;图像传感器进行时间积分曝光;对数据进行转换、传输、处理和存储;对采集到的数据进行计算。所述装置包括:入射单元;出射单元;数据采集处理单元;数据采集处理单元通过硬触发的方式来触发出射单元获得样品的椭偏图像。本发明利用时间积分方法进行采样大幅度提高了系统的时间分辨率即减少了采样时间;采用匀速旋转相位补偿器达到了稳定的目的,能够保证操控精度
An automatic focusing method for the imaging of an illumination-tilted specular-reflection imaging system
倾料镜面成像系统的像面与光轴倾料,仅利用轴向自动调焦无法实现像面整体清晰。为此提出一种基于图像清晰度判断的自动调焦方法。该方法将轴向调焦与角度调焦相结合,通过步进方式平移和旋转像接收面,利用离焦函数判断聚焦情况,采用数据拟合回归的方法实现了像面整体清晰。该方法在椭偏成像系统的应用结果验证了其有效性,调焦精度达到微米量级
一种用于光度测量中的调节装置
本实用新型涉及一种用于光度测量中的调节装置,包括在椭偏测量装置中还设置一线性偏振器12、用于固定线性偏振器12的中空的偏振器旋转台13、一数据采集器43、一控制箱41以及一电子计算机42;线性偏振器12放置在椭偏测量装置入射光轴上,处于线性起偏器14前,并与线性起偏器14的方位角有一个差θ(0°≤θ≤90°)。在进行光强调节时,由电子计算机42发出指令给控制箱41,控制箱41驱动偏振器旋转台13带动线性偏振器12围绕入射光轴旋转,从而改变线性偏振器12和线性起偏器14的方位角的夹角θ。在进行测量时,始终保持θ不变。本实用新型的调节装置对光强可以进行连续的大范围内的调节,且该调节装置结构简单
入射角度扫描椭偏成像测量方法和装置
本发明涉及一种入射角度扫描椭偏成像装置和方法,入射光轴与出射光轴相交于待测样品上一点并形成入射面,待测样品垂直于入射面;入射部分和出射部分中的各光学器件共轴安装在二者确定的光轴上;入射部分发出的扩展的准直、准单色偏振光束,照明到待测样品上,样品对入射光的偏振态进行调制后发出反射的偏振光束,该光束进入出射部分中再次进行偏振态的调制后成像在图像传感器上形成图像的电信号;此电信号进入图像处理及系统控制部分进行图像采集、显示及分析处理,计算机对系统中的各运动部件进行驱动、控制,并接收运动反馈,从而实现对对纳米薄膜表面形貌的多个参数进行定性或定量测量
椭偏光学显微成像系统中的图像采集及处理技术
针对椭偏光学显微成像系统及其成像(简称“椭偏成像”)特点,提出了扩展图像量化等级法、快速采样-时间积分法和多采样点平均法以改善椭偏成像质量和样品表面定量分析的可靠性,并给出理论分析及实验结果。这些图像采集和图像处理技术在椭偏光学显微成像系统中行之有效,同时也适用于类似的图像处理系统
- …
