4,469 research outputs found

    Concept and development of an autonomous wearable micro-fluidic platform for real time pH sweat analysis

    Get PDF
    In this work the development of an autonomous, robust and wearable micro-fluidic platform capable of performing on-line analysis of pH in sweat is discussed. Through the means of an optical detection system based on a surface mount light emitting diode (SMD LED) and a light photo sensor as a detector, a wearable system was achieved in which real-time monitoring of sweat pH was performed during 55 minutes of cycling activity. We have shown how through systems engineering, integrating miniaturised electrical components, and by improving the micro-fluidic chip characteristics, the wearability, reliability and performance of the micro-fluidic platform was significantly improved

    Textile-based wearable sensors for assisting sports performance

    Get PDF
    There is a need for wearable sensors to assess physiological signals and body kinematics during exercise. Such sensors need to be straightforward to use, and ideally the complete system integrated fully within a garment. This would allow wearers to monitor their progress as they undergo an exercise training programme without the need to attach external devices. This takes physiological monitoring into a more natural setting. By developing textile sensors the intelligence is integrated into a sports garment in an innocuous manner. A number of textile based sensors are presented here that have been integrated into garments for various sports applications

    Stretchable pH Sensing Patch in a Hybrid Package

    Get PDF
    This work presents a novel stretchable pH sensing patch to detect the pH in body fluid which is one of the most important parameters in human health monitoring. The sensing patch is a hybrid package comprising of polyimide/gold-based stretchable interconnects and graphite composite-based flexible pH sensor. With the integration of stretchable interconnects, the patch is able to withstand external stretching up to 50% longer than its original length. Moreover, the electrical behavior of the patch does not degrade as studied by the real-time resistance investigation. In order to protect the connecting electrodes and wirings from direct contacting with solution under analysis, the sensing patch is encapsulated with elastic polymer with the active sensing area exposed. The fabricated patch reveals a high pH sensitivity of 36.2 μA/pH in the pH range between 5 and 9 which is validated through electrochemical and electroanalytical studies

    Fibers and fabrics for chemical and biological sensing

    Get PDF
    Wearable sensors can be used to monitor many interesting parameters about the wearer’s physiology and environment, with important applications in personal health and well-being, sports performance and personal safety. Wearable chemical sensors can monitor the status of the wearer by accessing body fluids, such as sweat, in an unobtrusive manner. They can also be used to protect the wearer from hazards in the environment by sampling potentially harmful gas emissions such as carbon monoxide. Integrating chemical sensors into textile structures is a challenging and complex task. Issues which must be considered include sample collection, calibration, waste handling, fouling and reliability. Sensors must also be durable and comfortable to wear. Here we present examples of wearable chemical sensors that monitor the person and also their environment. We also discuss the issues involved in developing wearable chemical sensors and strategies for sensor design and textile integration

    Wireless body sensor networks for health-monitoring applications

    Get PDF
    This is an author-created, un-copyedited version of an article accepted for publication in Physiological Measurement. The publisher is not responsible for any errors or omissions in this version of the manuscript or any version derived from it. The Version of Record is available online at http://dx.doi.org/10.1088/0967-3334/29/11/R01

    BIOTEX-biosensing textiles for personalised healthcare management.

    Get PDF
    Textile-based sensors offer an unobtrusive method of continually monitoring physiological parameters during daily activities. Chemical analysis of body fluids, noninvasively, is a novel and exciting area of personalized wearable healthcare systems. BIOTEX was an EU-funded project that aimed to develop textile sensors to measure physiological parameters and the chemical composition of body fluids, with a particular interest in sweat. A wearable sensing system has been developed that integrates a textile-based fluid handling system for sample collection and transport with a number of sensors including sodium, conductivity, and pH sensors. Sensors for sweat rate, ECG, respiration, and blood oxygenation were also developed. For the first time, it has been possible to monitor a number of physiological parameters together with sweat composition in real time. This has been carried out via a network of wearable sensors distributed around the body of a subject user. This has huge implications for the field of sports and human performance and opens a whole new field of research in the clinical setting

    Fully Integrated Biochip Platforms for Advanced Healthcare

    Get PDF
    Recent advances in microelectronics and biosensors are enabling developments of innovative biochips for advanced healthcare by providing fully integrated platforms for continuous monitoring of a large set of human disease biomarkers. Continuous monitoring of several human metabolites can be addressed by using fully integrated and minimally invasive devices located in the sub-cutis, typically in the peritoneal region. This extends the techniques of continuous monitoring of glucose currently being pursued with diabetic patients. However, several issues have to be considered in order to succeed in developing fully integrated and minimally invasive implantable devices. These innovative devices require a high-degree of integration, minimal invasive surgery, long-term biocompatibility, security and privacy in data transmission, high reliability, high reproducibility, high specificity, low detection limit and high sensitivity. Recent advances in the field have already proposed possible solutions for several of these issues. The aim of the present paper is to present a broad spectrum of recent results and to propose future directions of development in order to obtain fully implantable systems for the continuous monitoring of the human metabolism in advanced healthcare applications

    Textile sensors to measure sweat pH and sweat-rate during exercise

    Get PDF
    Sweat analysis can provide a valuable insight into a person’s well-being. Here we present wearable textile-based sensors that can provide real-time information regarding sweat activity. A pH sensitive dye incorporated into a fabric fluidic system is used to determine sweat pH. To detect the onset of sweat activity a sweat rate sensor is incorporated into a textile substrate. The sensors are integrated into a waistband and controlled by a central unit with wireless connectivity. The use of such sensors for sweat analysis may provide valuable physiological information for applications in sports performance and also in healthcare
    corecore