2,008 research outputs found
The Role of Nonlinear Dynamics in Quantitative Atomic Force Microscopy
Various methods of force measurement with the Atomic Force Microscope (AFM)
are compared for their ability to accurately determine the tip-surface force
from analysis of the nonlinear cantilever motion. It is explained how
intermodulation, or the frequency mixing of multiple drive tones by the
nonlinear tip-surface force, can be used to concentrate the nonlinear motion in
a narrow band of frequency near the cantilevers fundamental resonance, where
accuracy and sensitivity of force measurement are greatest. Two different
methods for reconstructing tip-surface forces from intermodulation spectra are
explained. The reconstruction of both conservative and dissipative tip-surface
interactions from intermodulation spectra are demonstrated on simulated data.Comment: 25 pages (preprint, double space) 7 figure
Calibration of piezoelectric positioning actuators using a reference voltage-to-displacement transducer based on quartz tuning forks
We use a piezoelectric quartz tuning fork to calibrate the displacement of
ceramic piezoelectric scanners which are widely employed in scanning probe
microscopy. We measure the static piezoelectric response of a quartz tuning
fork and find it to be highly linear, non-hysteretic and with negligible creep.
These performance characteristics, close to those of an ideal transducer, make
quartz transducers superior to ceramic piezoelectric actuators. Furthermore,
quartz actuators in the form of a tuning fork have the advantage of yielding
static displacements comparable to those of local probe microscope scanners. We
use the static displacement of a quartz tuning fork as a reference to calibrate
the three axis displacement of a ceramic piezoelectric scanner. Although this
calibration technique is a non-traceable method, it can be more versatile than
using calibration grids because it enables to characterize the linear and
non-linear response of a piezoelectric scanner in a broad range of
displacements, spanning from a fraction of a nanometer to hundreds of
nanometers. In addition, the creep and the speed dependent piezoelectric
response of ceramic scanners can be studied in detail.Comment: 9 pages, 3 figure
Handbook of recommended practices for the determination of liquid monopropellant rocket engine performance
The design, installation, and operation of systems to be used for directly measuring quantities of fundamental importance to the determination of monopropellant thruster performance is described. Areas covered include: (1) force and impulse measurement; (2) propellant mass usage and flow measurement; (3) pressure measurement; (4) temperature measurement; (5) exhaust gas composition measurement; and (6) data reduction and performance determination
Realization of Sinusoidal Forces at CEM
This paper describes the procedure implemented at CEM for dynamic force calibration using sinusoidal excitations of force transducers. The method is based on a sinusoidal excitation of force transducers equipped with an additional top mass excited with an electrodynamic shaker system. The acceleration is measured by means of a laser vibrometer
Replication of Known Dental Characteristics in Porcine Skin: Emerging Technologies for the Imaging Specialist
This study demonstrates that it is sometimes possible to replicate patterns of human teeth in pig skin and determine scientifically that a given injury pattern (bite mark) correlates with the dentitions of a very small proportion of a population dataset, e.g., 5 percent or even 1 percent. The authors recommend building on the template of this research with a sufficiently large database of samples that reflects the diverse world population. They also envision the development of a sophisticated imaging software application that enables forensic examiners to insert parameters for measurement, as well as additional methods of applying force to produce bite marks for research. The authors further advise that this project is applied science for injury pattern analysis and is only foundational research that should not be cited in testimony and judicial procedures. It supplements but does not contradict current guidelines of the American Board of Forensic Odontology regarding bite mark analysis and comparisons. A much larger population database must be developed. The project’s methodology is described in detail, accompanied by 11 tables and 41 figures
Fluorine-hydrogen performance evaluation. Phase I, part I - Analysis, design, and demonstration of high performance injectors for the liquid fluorine-gaseous hydrogen combination Final report
Analysis, design, and demonstration of high performance injectors for liquid fluorine- gaseous hydrogen propellant combinatio
Analysis of the conical piezoelectric acoustic emission transducer
Analyses of the properties of conical piezoelectric acoustic emission transducer are presented here. The conical piezoelectric transducer is used to scanning normal displacement on a surface of testing constructions in NDT methods, such as acoustic emission. The simplified one-dimensional analysis based on the equivalent circuit of conical waveguide is recapitulated. FEM analysis on this transducer is presented. Both the frequency response characteristic of the transducer and his time response on pulse excitation are results of this analysis. All of computations are done for various cone angles of piezoceramic (PTZ-H5) element and various sizes of the cylindrical backing of the sensor
Experimental clean combustor program: Noise study
Under a Noise Addendum to the NASA Experimental Clean Combustor Program (ECCP) internal pressure fluctuations were measured during tests of JT9D combustor designs conducted in a burner test rig. Measurements were correlated with burner operating parameters using an expression relating farfield noise to these parameters. For a given combustor, variation of internal noise with operating parameters was reasonably well predicted by this expression but the levels were higher than farfield predictions and differed significantly among several combustors. For two burners, discharge stream temperature fluctuations were obtained with fast-response thermocouples to allow calculation of indirect combustion noise which would be generated by passage of the temperature inhomogeneities through the high pressure turbine stages of a JT9D turbofan engine. Using a previously developed analysis, the computed indirect combustion noise was significantly lower than total low frequency core noise observed on this and several other engines
Instrumentation for measuring the dynamic pressure on rotating compressor blades
To establish the capability for measurement of oscillatory pressure on rotating blades, miniature fast response semiconductor strain gage pressure transducers (2mm x 0.33mm) were mounted in several configurations on thin titanium and steel compressor blades and subjected to pressure cycles from 1 to 310 kPa during static tests and spin tests. Static test conditions included 20 C to 150 C, 0 to 3000 tensile microstrain, -1000 to +1000 bending microstrain and + or - 650G vibration. The spin test conditions included 20 C to 82 C at 0 to 90,000G. Durability was excellent. Pressure transducer sensitivity changed by only a few percent over this range of environmental conditions. Noise signal due to oscillatory acceleration normal to the diaphragm was acceptable (0.33Pa/G). Noise signal due to oscillatory strain was acceptable (0.5 Pa/microstrain) when the transducer was mounted on a 0.05mm rubber pad, with a total buildup of 0.38mm on the measure surface. Back mounting or partial recessing to eliminate buildup, increased the strain effect to 1.2 Pa/microstrain. Flush mounting within the blade to eliminate buildup reduced the strain effect, but required development of a special transducer shape. This transducer was not available in time for spin tests. Unpredictable zero drift + or - 14 kPa ruled out the use of these mounting arrangements for accurate steady-state (D.C.) measurements on rotating blades. The two best configurations fully developed and spin tested were then successfully applied in the NAS3-20606 rotating fan flutter program for quantitative measurement of oscillatory pressure amplitudes
- …
