94,197 research outputs found
Comparison of multidetector-row computed tomography and duplex Doppler ultrasonography in detecting atherosclerotic carotid plaques complicated with intraplaque hemorrhage [Usporedba višeslojne kompjuterizirane tomografije i duplex Doppler ultrazvuka u otkrivanju aterosklerotskih karotidnih plakova kompliciranih krvarenjem u plak ]
This study compared sensitivity and specificity of multidetector-row computed tomography and duplex Doppler ultrasonography in detecting atherosclerotic carotid plaques complicated with intraplaque hemorrhage. Carotid plaques from 50 patients operated for carotid artery stenosis were analyzed. Carotid endarterectomy was performed within one week of diagnostic evaluation. Results of multidetector-row computed tomography and duplex Doppler ultrasonography diagnostic evaluation were compared with results of histological analysis of the same plaque areas. American Heart Association classification of atherosclerotic plaques was applied for histological classification. Median tissue density of carotid plaques complicated with intraplaque hemorrhage was 14.7 Hounsfield units. Median tissue density of noncalcified segments of uncomplicated plaques was 54.3 Hounsfield units (p = 0.00003). The highest tissue density observed for complicated plaques was 31.8 Hounsfield units. Multidetector-row computed tomography detected plaques complicated with hemorrhage with sensitivity of 100% and specificity of 70.4%, with tissue density of 33.8 Hounsfield units as a threshold value. Duplex Doppler ultrasonography plaque analysis based on visual in-line classification showed sensitivity of 21.7% and specificity of 89.6% in detecting plaques complicated with intraplaque hemorrhage. Multidetector-row computed tomography showed a very high level of sensitivity and a moderate level of specificity in detecting atherosclerotic carotid plaques complicated with hemorrhage. Duplex Doppler ultrasonography plaque analysis based on visual in-line classification showed a low level of sensitivity and a moderate-high level of specificity in detecting atherosclerotic carotid plaques complicated with hemorrhage
Investigation of Lower-limb Tissue Perfusion during Loading
An extant tissue indentor used for amputee residual limb tissue indentation studies was modified to include laser Doppler flowmetry (LDF) to enable measurement of tissue perfusion during indentation. This device allows quantitative assessment of the mechanical and physiological response of soft tissues to load, as demonstrated by indentation studies of the lower-limb tissues of young healthy subjects. Potential measures of interest include the relative change in tissue perfusion with load and the time delays associated with the perfusion response during tissue loading and unloading. Such measures may prove useful in future studies of residual limb tissues, improving our understanding of tissue viability risk factors for individuals with lower-limb amputation
Hearing the Hidden Agenda: The Ethnographic Investigation of Procedure
Laser Doppler flowmetry (LDF) is virtually the only non-invasive technique, except for other laser speckle based techniques, that enables estimation of the microcirculatory blood flow. The technique was introduced into the field of biomedical engineering in the 1970s, and a rapid evolvement followed during the 1980s with fiber based systems and improved signal analysis. The first imaging systems were presented in the beginning of the 1990s. Conventional LDF, although unique in many aspects and elegant as a method, is accompanied by a number of limitations that may have reduced the clinical impact of the technique. The analysis model published by Bonner and Nossal in 1981, which is the basis for conventional LDF, is limited to measurements given in arbitrary and relative units, unknown and non-constant measurement volume, non-linearities at increased blood tissue fractions, and a relative average velocity estimate. In this thesis a new LDF analysis method, quantitative LDF, is presented. The method is based on recent models for light-tissue interaction, comprising the current knowledge of tissue structure and optical properties, making it fundamentally different from the Bonner and Nossal model. Furthermore and most importantly, the method eliminates or highly reduces the limitations mentioned above. Central to quantitative LDF is Monte Carlo (MC) simulations of light transport in tissue models, including multiple Doppler shifts by red blood cells (RBC). MC was used in the first proof-of-concept study where the principles of the quantitative LDF were tested using plastic flow phantoms. An optically and physiologically relevant skin model suitable for MC was then developed. MC simulations of that model as well as of homogeneous tissue relevant models were used to evaluate the measurement depth and volume of conventional LDF systems. Moreover, a variance reduction technique enabling the reduction of simulation times in orders of magnitudes for imaging based MC setups was presented. The principle of the quantitative LDF method is to solve the reverse engineering problem of matching measured and calculated Doppler power spectra at two different source-detector separations. The forward problem of calculating the Doppler power spectra from a model is solved by mixing optical Doppler spectra, based on the scattering phase functions and the velocity distribution of the RBC, from various layers in the model and for various amounts of Doppler shifts. The Doppler shift distribution is calculated based on the scattering coefficient of the RBC:s and the path length distribution of the photons in the model, where the latter is given from a few basal MC simulations. When a proper spectral matching is found, via iterative model parameters updates, the absolute measurement data are given directly from the model. The concentration is given in g RBC/100 g tissue, velocities in mm/s, and perfusion in g RBC/100 g tissue × mm/s. The RBC perfusion is separated into three velocity regions, below 1 mm/s, between 1 and 10 mm/s, and above 10 mm/s. Furthermore, the measures are given for a constant output volume of a 3 mm3 half sphere, i.e. within 1.13 mm from the light emitting fiber of the measurement probe. The quantitative LDF method was used in a study on microcirculatory changes in type 2 diabetes. It was concluded that the perfusion response to a local increase in skin temperature, a response that is reduced in diabetes, is a process involving only intermediate and high flow velocities and thus relatively large vessels in the microcirculation. The increased flow in higher velocities was expected, but could not previously be demonstrated with conventional LDF. The lack of increase in low velocity flow indicates a normal metabolic demand during heating. Furthermore, a correlation between the perfusion at low and intermediate flow velocities and diabetes duration was found. Interestingly, these correlations were opposites (negative for the low velocity region and positive for the mediate velocity region). This finding is well in line with the increased shunt flow and reduced nutritive capillary flow that has previously been observed in diabetes
Echocardiography during submaximal isometric exercise in children with repaired coarctation of the aorta compared with controls
Objective Patients with repaired coarctation (RCoA) remain at higher risk of cardiac dysfunction, initially often only detected during exercise. In this study, haemodynamics of isometric handgrip (HG) and bicycle ergometry (BE) were compared in patients with RCoA and matched controls (MCs).
Methods Case-control study of 19 children with RCoA (mean age 12.9 +/- 2.3 years; mean age of repair 7 months) compared with 20 MC. HG with echocardiography followed by BE was performed in both groups.
Results During HG (blood pressure) BP increased from 114 +/- 11/64 +/- 4 mm Hg to 132 +/- 14/79 +/- 7 mm Hg, without significant differences. During HG as well as BE, HR increased less in patients with RCoA. There were no significant differences in (left ventricle) LV dimensions or LV mass.
The RCoA group had diastolic dysfunction: both at rest and during HG they had significantly higher transmitral E and A velocities and lower tissue Doppler E' and A' velocities. E/E' was higher, reaching statistical significance during HG (p<0001).
Conventional parameters of systolic function (FS and EF) were similar at rest and HG. More sensitive tissue Doppler S' was significantly lower at rest in CoA subjects (5.1 +/- 1.5 cm/s vs 6.5 +/- 1 +/- 1 cm/s; p<0.01), decreasing further during HG by 5% in the CoA group (NS) while unchanged in controls.
Conclusions We provide first evidence that HG with echocardiography is feasible, easy and patient-friendly. A decreased systolic (tissue Doppler) and impaired diastolic LV function was measured in the RCoA group, a difference that tended to increase during HG
Measurement of particle flux in a static matrix with suppressed influence of optical properties, using low coherence interferometry
Perfusion measurements using conventional laser Doppler techniques are affected by the variations in tissue optical properties. Differences in absorption and scattering will induce different path lengths and consequently will alter the probability that a Doppler shift will occur. In this study, the fraction of Doppler shifted photons and the Doppler broadening of a dynamic medium, are measured with a phase modulated low coherence Mach-Zehnder interferometer. Path length-resolved dynamic light scattering measurements are performed in various media having a constant concentration of dynamic particles inside a static matrix with different scattering properties and the results are compared with a conventional laser Doppler technique, with a simple model and with Monte Carlo simulations. We demonstrate that, for larger optical path lengths, the scattering coefficient of the static matrix in which the moving particles are embedded have a small to minimal effect on the measured fraction of Doppler shifted photons and on the measured average Doppler frequency of the Doppler shifted light. This approach has potential applications in measuring perfusion independent of the influence of optical properties in the static tissue matrix
Impaired myocardial relaxation with exercise determines peak aerobic exercise capacity in heart failure with preserved ejection fraction
Background
Heart failure with preserved ejection fraction (HFpEF) is a clinical syndrome characterized by impaired exercise capacity due to shortness of breath and/or fatigue. Assessment of diastolic dysfunction at rest and with exercise may provide insight into the pathophysiology of exercise intolerance in HFpEF. Aims
To measure echocardio-Doppler-derived parameters of diastolic function as they relate to various indices of aerobic exercise capacity in HFpEF. Methods
We selected 16 subjects with clinically stable HFpEF, no evidence of volume overload, but impaired functional capacity by cardiopulmonary exercise testing [peak oxygen consumption (VO2)]. We measured the transmitral E and A flow velocities, E/A ratio, and E deceleration time (DT) and tissue Doppler E′ velocity. We also indexed the E′ to the DT, as additional measure of impaired relaxation (E′DT), and calculated the diastolic functional reserve index (DFRI), as the product of E′ at rest and change in E′ with exercise. Results
E′ velocity, at rest and peak exercise, as well as the DFRI positively correlated with peak VO2, whereas DT, E′DT, and E/E′ with exercise inversely correlated with peak VO2. Of note, the E′DT at rest also significantly predicted E′ velocity at peak exercise (R = +0.81, P \u3c 0.001). Exercise E′ was the only independent predictor of peak VO2 at multivariable analysis (R = +0.67, P = 0.005). Conclusions
The E′ velocity at peak exercise is a strong and independent predictor of aerobic exercise capacity as measured by peak VO2 in patients with HFpEF, providing the link between abnormal myocardial relaxation with exercise and impaired aerobic exercise capacity in HFpEF
Techniques for Identification of Left Ventricular Asynchrony for Cardiac Resynchronization Therapy in Heart Failure
The most recent treatment option of medically refractory heart failure includes cardiac resynchronization therapy (CRT) by biventricular pacing in selected patients in NYHA functional class III or IV heart failure. The widely used marker to indicate left ventricular (LV) asynchrony has been the surface ECG, but seems not to be a sufficient marker of the mechanical events within the LV and prediction of clinical response. This review presents an overview of techniques for identification of left ventricular intra- and interventricular asynchrony. Both manuscripts for electrical and mechanical asynchrony are reviewed, partly predicting response to CRT. In summary there is still no gold standard for assessment of LV asynchrony for CRT, but both traditional and new echocardiographic methods have shown asynchronous LV contraction in heart failure patients, and resynchronized LV contraction during CRT and should be implemented as additional methods for selecting patients to CRT
Angiogenic gene expression and vascular density are reflected in ultrasonographic features of synovitis in early Rheumatoid Arthritis: an observational study.
INTRODUCTION: Neovascularization contributes to the development of sustained synovial inflammation in the early stages of Rheumatoid Arthritis. Ultrasound (US) provides an indirect method of assessing synovial blood flow and has been shown to correlate with clinical disease activity in patients with Rheumatoid Arthritis. This study examines the relationship of US determined synovitis with synovial vascularity, angiogenic/lymphangiogenic factors and cellular mediators of inflammation in a cohort of patients with early Rheumatoid Arthritis (RA) patients prior to therapeutic intervention with disease modifying therapy or corticosteroids. METHODS: An ultrasound guided synovial biopsy of the supra-patella pouch was performed in 12 patients with early RA prior to treatment. Clinical, US and biochemical assessments were undertaken prior to the procedure. Ultrasound images and histological samples were obtained from the supra-patella pouch. Histological samples were stained for Factor VIII and a-SMA (a-smooth muscle actin). Using digital imaging analysis a vascular area score was recorded. QT-PCR (quantitative-PCR) of samples provided quantification of angiogenic and lymphangiogenic gene expression and immunohistochemistry stained tissue was scored for macrophage, T cell and B cell infiltration using an existing semi-quantitative score. RESULTS: Power Doppler showed a good correlation with histological vascular area (Spearman r--0.73) and angiogenic factors such as vascular endothelial growth factor-A (VEGF-A), Angiopoietin 2 and Tie-2. In addition, lymphangiogenic factors such as VEGF-C and VEGF-R3 correlated well with US assessment of synovitis. A significant correlation was also found between power Doppler and synovial thickness, pro-inflammatory cytokines and sub-lining macrophage infiltrate. Within the supra-patella pouch there was no significant difference in US findings, gene expression or inflammatory cell infiltrate between any regions of synovium biopsied. CONCLUSION: Ultrasound assessment of synovial tissue faithfully reflects synovial vascularity. Both grey scale and power Doppler synovitis in early RA patients correlate with a pro-angiogenic and lymphangiogenic gene expression profile. In early RA both grey scale and power Doppler synovitis are associated with a pro-inflammatory cellular and cytokine profile providing considerable validity in its use as an objective assessment of synovial inflammation in clinical practice
- …
