5 research outputs found

    Unsupervised Heart-rate Estimation in Wearables With Liquid States and A Probabilistic Readout

    Full text link
    Heart-rate estimation is a fundamental feature of modern wearable devices. In this paper we propose a machine intelligent approach for heart-rate estimation from electrocardiogram (ECG) data collected using wearable devices. The novelty of our approach lies in (1) encoding spatio-temporal properties of ECG signals directly into spike train and using this to excite recurrently connected spiking neurons in a Liquid State Machine computation model; (2) a novel learning algorithm; and (3) an intelligently designed unsupervised readout based on Fuzzy c-Means clustering of spike responses from a subset of neurons (Liquid states), selected using particle swarm optimization. Our approach differs from existing works by learning directly from ECG signals (allowing personalization), without requiring costly data annotations. Additionally, our approach can be easily implemented on state-of-the-art spiking-based neuromorphic systems, offering high accuracy, yet significantly low energy footprint, leading to an extended battery life of wearable devices. We validated our approach with CARLsim, a GPU accelerated spiking neural network simulator modeling Izhikevich spiking neurons with Spike Timing Dependent Plasticity (STDP) and homeostatic scaling. A range of subjects are considered from in-house clinical trials and public ECG databases. Results show high accuracy and low energy footprint in heart-rate estimation across subjects with and without cardiac irregularities, signifying the strong potential of this approach to be integrated in future wearable devices.Comment: 51 pages, 12 figures, 6 tables, 95 references. Under submission at Elsevier Neural Network

    Evaluación de técnicas para la estimación del ritmo cardíaco

    Get PDF
    Según datos de la Organización Mundial de la Salud, las enfermedades cardiovasculares son la principal causa de defunción en el mundo. En 2012 se registraron 17.5 millones de muertes por esta causa, lo cual representa un 31% del total de muertes mundiales. De este número, más de tres cuartas partes se produjeron en países de ingresos medios y bajos [1]. Si nos restringimos al ámbito nacional, en 2014 se registraron 128.169 muertes por este tipo de enfermedades, suponiendo un coste para las arcas españolas de 7.700 millones de euros [2]. Se prevé que el gasto dedicado a tratar las anomalías cardíacas siga creciendo hasta alcanzar un coste per cápita de 180 euros en 2020, frente a los 124 de 2014. Por estos motivos, muchos investigadores dedicados al campo de la medicina han puesto sus ojos en la investigación sobre enfermedades cardiovasculares, intentando mejorar las formas tradicionales de diagnóstico existentes en los centros hospitalarios. En la actualidad, los diagnósticos por imagen [3] son una de las herramientas más utilizadas para la prevención de las enfermedades cardiovasculares. Otra prueba muy común es el electrocardiograma (ECG), ya que es una prueba no invasiva, simple, barata y capaz de ofrecer mucha información al facultativo para un correcto diagnóstico...Universidad de Sevilla. Grado en Ingeniería de las Tecnologías de Telecomunicació

    Threshold-Independent QRS Detection Using the Dynamic Plosion Index

    No full text
    Detection of QRS serves as a first step in many automated ECG analysis techniques. Motivated by the strong similarities between the signal structures of an ECG signal and the integrated linear prediction residual (ILPR) of voiced speech, an algorithm proposed earlier for epoch detection from ILPR is extended to the problem of QRS detection. The ECG signal is pre-processed by high-pass filtering to remove the baseline wandering and by half-wave rectification to reduce the ambiguities. The initial estimates of the QRS are iteratively obtained using a non-linear temporal feature, named the dynamic plosion index suitable for detection of transients in a signal. These estimates are further refined to obtain a higher temporal accuracy. Unlike most of the high performance algorithms, this technique does not make use of any threshold or differencing operation. The proposed algorithm is validated on the MIT-BIH database using the standard metrics and its performance is found to be comparable to the state-of-the-art algorithms, despite its threshold independence and simple decision logic

    Novel Low Complexity Biomedical Signal Processing Techniques for Online Applications

    Get PDF
    Biomedical signal processing has become a very active domain of research nowadays. With the advent of portable monitoring devices, from accelerometer-enabled bracelets and smart-phones to more advanced vital sign tracking body area networks, this field has been receiving unprecedented attention. Indeed, portable health monitoring can help uncover the underlying dynamics of human health in a way that has not been possible before. Several challenges have emerged however, as these devices present key differences in terms of signal acquisition and processing in comparison with conventional methods. Hardware constraints such as processing power and limited battery capacity make most established techniques unsuitable and therefore, the need for low-complexity yet robust signal processing methods has appeared. Another issue that needs to be addressed is the quality of the signals captured by these devices. Unlike in clinical scenarios, in portable health monitoring subjects are constantly performing their daily activities. Moreover, signals maybe captured from unconventional locations and subsequently, be prone to perturbations. In order to obtain reliable measures from these monitoring devices, one needs to acquire dependable signal quality measures, to avoid false alarms. Indeed, hardware limitations and low-quality signals can greatly influence the performance of portable monitoring devices. Nevertheless, most devices offer simultaneous acquisition of multiple physiological parameters, such as electrocardiogram (ECG) and photoplethysmogram (PPG). Through multi-modal signal processing the overall performance can be improved, for instance by deriving parameters such as heart rate estimation from the most reliable and uncontaminated source. This thesis is therefore, dedicated to propose novel low-complexity biomedical processing techniques for real-time/online applications. Throughout this dissertation, several bio-signals such as the ECG, PPG, and electroencephalogram (EEG) are investigated. %There is an emphasis on ECG processing techniques, as most of the bio-signals recorded today reflect information about the heart. The main contribution of this dissertation consists in two signal processing techniques: 1) a novel ECG QRS-complex detection and delineation technique, and 2) a short-term event extraction technique for biomedical signals. The former is based on a processing technique called mathematical morphology (MM), and adaptively uses subject QRS-complex amplitude- and morphological attributes for a robust detection and delineation. This method is generalized to intra-cardiac electrograms for atrial activation detection during atrial fibrillation. The second method, called the Relative-Energy algorithm, uses short- and long-term signal energies to highlight events of interest and discard unwanted activities. Collectively, the results obtained by these methods suggest that while presenting low-computational costs, they can efficiently and robustly extract biomedical events of interest. Using the relative energy algorithm, a continuous non-binary ECG signal quality index is presented. The ECG quality is determined by creating a cleaned-up version of the input ECG and calculating the correlation coefficient between the cleaned-up and the original ECG. The proposed quality index is fast and can be implemented online, making it suitable for portable monitoring scenarios
    corecore