4 research outputs found

    Three-dimensional models of cochlear implants : a review of their development and how they could support management and maintenance of cochlear implant performance

    Get PDF
    Three-dimensional (3D) computational modelling of the auditory periphery forms an integral part of modern-day research in cochlear implants (CIs). These models consist of a volume conduction description of implanted stimulation electrodes and the current distribution around these, coupled to auditory nerve fibre models. Cochlear neural activation patterns can then be predicted for a given input stimulus. The objective of this article is to present the context of 3D modelling within the field of CIs, the different models and approaches to models that have been developed over the years, as well as the applications and potential applications of these models. The process of development of 3D models is discussed, and the article places specific emphasis on the complementary roles of generic models and user-specific models, as the latter is important for translation of these models into clinical application.http://tandfonline.com/toc/inet202017-05-31hb2016Electrical, Electronic and Computer Engineerin

    Three-dimensional localization of cochlear implant electrodes using epipolar stereophotogrammetry

    No full text
    Three-dimensional (3-D) localization of individual cochlear implant electrodes within the inner ear is of importance for modeling the electrical field of the cochlea, designing the electrode array, and programming the associated speech processor. A 3-D reconstruction method of cochlear implant electrodes is proposed to localize individual electrodes from two X-ray views in combination with the spiral computed tomography technique. By adapting epipolar geometry to the configuration of an X-ray imaging system, we estimate individual electrode locations in the least square sense without using a patient attachment required by an existing stereophotogrammetry technique. Furthermore, our method does not require any knowledge of the intrinsic and extrinsic parameters of the imaging system. The performance of our method is studied in numerical simulation and with patient data and is found to be sufficiently accurate for clinical use. The maximum root mean-square errors measured are 0.0445 and 0.214 mm for numerical simulation and patient data, respectively.restrictio

    Interlandmark measurements from lodox statscan images with application to femoral neck anteversion assessment

    Get PDF
    Includes abstract.Includes bibliographical references.Clinicians often take measurements between anatomical landmarks on X-ray radiographs for diagnosis and treatment planning, for example in orthopaedics and orthodontics. X-ray images, however, overlap three-dimensional internal structures onto a two-dimensional plane during image formation. Depth information is therefore lost and measurements do not truly reflect spatial relationships. The main aim of this study was to develop an inter-landmark measurement tool for the Lodox Statscan digital radiography system. X-ray stereophotogrammetry was applied to Statscan images to enable three-dimensional point localization for inter-landmark measurement using two-dimensional radiographs. This technique requires images of the anatomical region of interest to be acquired from different perspectives as well as a suitable calibration tool to map image coordinates to real world coordinates. The Statscan is suited to the technique because it is capable of axial rotations for multiview imaging. Three-dimensional coordinate reconstruction and inter-landmark measurements were taken using a planar object and a dry pelvis specimen in order to assess the intra-observer measurement accuracy, reliability and precision. The system yielded average (X, Y, Z) coordinate reconstruction accuracy of (0.08 0.12 0.34) mm and resultant coordinate reconstruction accuracy within 0.4mm (range 0.3mm – 0.6mm). Inter-landmark measurements within 2mm for lengths and 1.80 for angles were obtained, with average accuracies of 0.4mm (range 0.0mm – 2.0 mm) and 0.30 (range 0.0 – 1.8)0 respectively. The results also showed excellent overall precision of (0.5mm, 0.10) and were highly reliable when all landmarks were completely visible in both images. Femoral neck anteversion measurement on Statscan images was also explored using 30 dry right adult femurs. This was done in order to assess the feasibility of the algorithm for a clinical application. For this investigation, four methods were tested to determine the optimal landmarks for measurement and the measurement process involved calculation of virtual landmarks. The method that yielded the best results produced all measurements within 10 of reference values and the measurements were highly reliable with very good precision within 0.10. The average accuracy was within 0.40 (range 0.10 –0.80).In conclusion, X-ray stereophotogrammetry enables accurate, reliable and precise inter-landmark measurements for the Lodox Statscan X-ray imaging system. The machine may therefore be used as an inter-landmark measurement tool for routine clinical applications
    corecore