    Continuous roadmapping in liver TACE procedures using 2D–3D catheter-based registration

    Get PDF
    PURPOSE: Fusion of pre/perioperative images and intra-operative images may add relevant information during image-guided procedures. In abdominal procedures, respiratory motion changes the position of organs, and thus accurate image guidance requires a continuous update of the spatial alignment of the (pre/perioperative) information with the organ position during the intervention. METHODS: In this paper, we propose a method to register in real time perioperative 3D rotational angiography images (3DRA) to intra-operative single-plane 2D fluoroscopic images for improved guidance in TACE interventions. The method uses the shape of 3D vessels extracted from the 3DRA and the 2D catheter shape extracted from fluoroscopy. First, the appropriate 3D vessel is selected from the complete vascular tree using a shape similarity metric. Subsequently, the catheter is registered to this vessel, and the 3DRA is visualized based on the registration results. The method is evaluated on simulated data and clinical data. RESULTS: The first selected vessel, ranked with the shape similarity metric, is used more than 39 % in the final registration and the second more than 21 %. The median of the closest corresponding points distance between 2D angiography vessels and projected 3D vessels is 4.7–5.4 mm when using the brute force optimizer and 5.2–6.6 mm when using the Powell optimizer. CONCLUSION: We present a catheter-based registration method to continuously fuse a 3DRA roadmap arterial tree onto 2D fluoroscopic images with an efficient shape similarity

    Constrained Stochastic State Estimation for 3D Shape Reconstruction of Catheters and Guidewires in Fluoroscopic Images

    Get PDF
    Minimally invasive fluoroscopy-based procedures are the gold standard for diagnosis and treatment of various pathologies of the cardiovascular system. This kind of procedures imply for the clinicians to infer the 3D shape of the device from 2D images, which is known to be an ill-posed problem. In this paper we present a method to reconstruct the 3D shape of the interventional device, with the aim of improving the navigation. The method combines a physics-based simulation with non-linear Bayesian filter. Whereas the physics-based model provides a prediction of the shape of the device navigating within the blood vessels (taking into account non-linear interactions between the catheter and the surrounding anatomy), an Unscented Kalman Filter is used to correct the navigation model using 2D image features as external observations. The proposed framework has been evaluated on both synthetic and real data, under different model parameterization, filter parameters tuning and external observations data-sets. Comparing the reconstructed 3D shape with a known ground truth, for the synthetic data-set, we obtained an average 3D Hausdorff distance of 0.07 ± 0.37 mm; the 3D distance at the tip equal to 0.021 ± 0.009 mm and the 3D mean distance at the distal segment of the catheter equal to 0.02 ± 0.008 mm. For the real data-set, the obtained average 3D Hausdorff Distance was of 0.95 ± 0.35 mm, the average 3D distance at the tip is equal to 0.7 ± 0.45 mm with an average 3D mean distance at the distal segment of 0.7 ± 0.46 mm. These results show the ability of our method to retrieve the 3D shape of the device, under a variety of filter parameterizations and challenging conditions: errors on the friction coefficient, ambiguous views and non-linear complex phenomena such as stick and slip motions

    Constrained Stochastic State Estimation of Deformable 1D Objects: Application to Single-view 3D Reconstruction of Catheters with Radio-opaque Markers

    Get PDF
    International audienceMinimally invasive fluoroscopy-based procedures are the gold standard for diagnosis and treatment of various pathologies of the cardiovascular system. This kind of procedures imply for the clinicians to infer the 3D shape of the device from 2D images, which is known to be an ill-posed 10 problem. In this paper we present a method to reconstruct the 3D shape of the interventional device, with the aim of improving the navigation. The method combines a physics-based simulation with non-linear Bayesian filter. Whereas the physics-based model provides a prediction of the shape of the device navigating within the blood vessels (taking into account non-linear interactions be-15 tween the catheter and the surrounding anatomy), an Unscented Kalman Filter is used to correct the navigation model using 2D image features as external observations. The proposed framework has been evaluated on both synthetic and real data, under different model parameterizations, filter parameters tuning and external observations data-sets. Comparing the reconstructed 3D shape with a known ground truth, for the synthetic data-set, we obtained average values for 3D Hausdorff Distance of 0.81±0.53mm0.81 ± 0.53 mm, for the 3D mean distance at the segment of 0.37±0.170.37 ± 0.17 mm and an average 3D tip error of 0.24±0.13mm0.24 ± 0.13 mm. For the real data-set,we obtained an average 3D Hausdorff distance of 1.74±0.77mm1.74 ± 0.77 mm, a average 3D mean distance at the distal segment of 0.91 ± 0.14 mm, an average 3D error on the tip of 0.53±0.09mm0.53 ± 0.09 mm. These results show the ability of our method to retrieve the 3D shape of the device, under a variety of filter parameterizations and challenging conditions: uncertainties on model parameterization, ambiguous views and non-linear complex phenomena such as stick and slip motions

    Improved Image Guidance in TACE Procedures

    Get PDF
    Purpose of the work in this thesis is to improve the image guidance in TACE procedures. More specifically, we intend to develop and evaluate technology that permits dynamic roadmapping based on a 3D model of the liver vasculature

    Interventional Tool Tracking Using Discrete Optimization

    Full text link

    Constrained Stochastic State Estimation of Deformable 1D Objects: Application to Single-view 3D Reconstruction of Catheters with Radio-opaque Markers

    Get PDF
    International audienceMinimally invasive fluoroscopy-based procedures are the gold standard for diagnosis and treatment of various pathologies of the cardiovascular system. This kind of procedures imply for the clinicians to infer the 3D shape of the device from 2D images, which is known to be an ill-posed 10 problem. In this paper we present a method to reconstruct the 3D shape of the interventional device, with the aim of improving the navigation. The method combines a physics-based simulation with non-linear Bayesian filter. Whereas the physics-based model provides a prediction of the shape of the device navigating within the blood vessels (taking into account non-linear interactions be-15 tween the catheter and the surrounding anatomy), an Unscented Kalman Filter is used to correct the navigation model using 2D image features as external observations. The proposed framework has been evaluated on both synthetic and real data, under different model parameterizations, filter parameters tuning and external observations data-sets. Comparing the reconstructed 3D shape with a known ground truth, for the synthetic data-set, we obtained average values for 3D Hausdorff Distance of 0.81±0.53mm0.81 ± 0.53 mm, for the 3D mean distance at the segment of 0.37±0.170.37 ± 0.17 mm and an average 3D tip error of 0.24±0.13mm0.24 ± 0.13 mm. For the real data-set,we obtained an average 3D Hausdorff distance of 1.74±0.77mm1.74 ± 0.77 mm, a average 3D mean distance at the distal segment of 0.91 ± 0.14 mm, an average 3D error on the tip of 0.53±0.09mm0.53 ± 0.09 mm. These results show the ability of our method to retrieve the 3D shape of the device, under a variety of filter parameterizations and challenging conditions: uncertainties on model parameterization, ambiguous views and non-linear complex phenomena such as stick and slip motions

    A Survey on the Current Status and Future Challenges Towards Objective Skills Assessment in Endovascular Surgery

    Get PDF
    Minimally-invasive endovascular interventions have evolved rapidly over the past decade, facilitated by breakthroughs in medical imaging and sensing, instrumentation and most recently robotics. Catheter based operations are potentially safer and applicable to a wider patient population due to the reduced comorbidity. As a result endovascular surgery has become the preferred treatment option for conditions previously treated with open surgery and as such the number of patients undergoing endovascular interventions is increasing every year. This fact coupled with a proclivity for reduced working hours, results in a requirement for efficient training and assessment of new surgeons, that deviates from the “see one, do one, teach one” model introduced by William Halsted, so that trainees obtain operational expertise in a shorter period. Developing more objective assessment tools based on quantitative metrics is now a recognised need in interventional training and this manuscript reports the current literature for endovascular skills assessment and the associated emerging technologies. A systematic search was performed on PubMed (MEDLINE), Google Scholar, IEEXplore and known journals using the keywords, “endovascular surgery”, “surgical skills”, “endovascular skills”, “surgical training endovascular” and “catheter skills”. Focusing explicitly on endovascular surgical skills, we group related works into three categories based on the metrics used; structured scales and checklists, simulation-based and motion-based metrics. This review highlights the key findings in each category and also provides suggestions for new research opportunities towards fully objective and automated surgical assessment solutions

    Context-aware learning for robot-assisted endovascular catheterization

    Get PDF
    Endovascular intervention has become a mainstream treatment of cardiovascular diseases. However, multiple challenges remain such as unwanted radiation exposures, limited two-dimensional image guidance, insufficient force perception and haptic cues. Fast evolving robot-assisted platforms improve the stability and accuracy of instrument manipulation. The master-slave system also removes radiation to the operator. However, the integration of robotic systems into the current surgical workflow is still debatable since repetitive, easy tasks have little value to be executed by the robotic teleoperation. Current systems offer very low autonomy, potential autonomous features could bring more benefits such as reduced cognitive workloads and human error, safer and more consistent instrument manipulation, ability to incorporate various medical imaging and sensing modalities. This research proposes frameworks for automated catheterisation with different machine learning-based algorithms, includes Learning-from-Demonstration, Reinforcement Learning, and Imitation Learning. Those frameworks focused on integrating context for tasks in the process of skill learning, hence achieving better adaptation to different situations and safer tool-tissue interactions. Furthermore, the autonomous feature was applied to next-generation, MR-safe robotic catheterisation platform. The results provide important insights into improving catheter navigation in the form of autonomous task planning, self-optimization with clinical relevant factors, and motivate the design of intelligent, intuitive, and collaborative robots under non-ionizing image modalities.Open Acces

    3D Reconstruction of Interventional Material from Very Few X-Ray Projections for Interventional Image Guidance

    Get PDF
    Today, minimally invasive endovascular interventions are usually guided by 2D fluoroscopy, i.e. a live 2D X-ray image. However, 3D fluoroscopy, i.e. a live 3D image reconstructed from a stream of 2D X-ray images, could improve spatial awareness. 3D fluoroscopy is, however, not used today, since no appropriate 3D reconstruction algorithm is known. Existing algorithms for the real-time reconstruction of interventional material (guidewires, stents, catheters, etc.) are either only capable of reconstructing a single guidewire or catheter, or use too many X-ray images and therefore too much dose per 3D reconstruction. The goal of this thesis was to reconstruct complex arrangements of interventional material from as few X-ray images as possible. To this end, a previously proposed algorithm for the reconstruction of interventional material from four X-ray images was adapted. Five key improvements allowed to reduce the number of X-ray images per 3D reconstruction from four to two: a) use of temporal information in a rotating imaging setup, b) separate reconstruction of different types of interventional material enabled by the computation of semantic interventional material extraction images, c) compensation of stent motion by spatial transformer networks, d) per-projection backprojection and e) binarization of the guidewire extraction images. While previously only single curves could be reconstructed from two newly acquired X-ray images, the proposed pipeline can reconstruct stents and even stent-guidewire combinations. Submillimeter reconstruction accuracy was demonstrated on measured X-ray images of interventional material inside an anthropomorphic phantom with simulated respiratory motion. Measurements of the dose area product rate of the proposed 3D reconstruction pipeline indicate a dose burden roughly similar to that of 2D fluoroscopy

    Three-dimensional guide wire visualization from 3DRA using monoplane fluoroscopic imaging