    Comparison of a prototype for indications-based prescribing with 2 commercial prescribing systems

    Get PDF
    Importance: The indication (reason for use) for a medication is rarely included on prescriptions despite repeated recommendations to do so. One barrier has been the way existing electronic prescribing systems have been designed. Objective: To evaluate, in comparison with the prescribing modules of 2 leading electronic health record prescribing systems, the efficiency, error rate, and satisfaction with a new computerized provider order entry prototype for the outpatient setting that allows clinicians to initiate prescribing using the indication. Design, Setting, and Participants: This quality improvement study used usability tests requiring internal medicine physicians, residents, and physician assistants to enter prescriptions electronically, including indication, for 8 clinical scenarios. The tool order assignments were randomized and prescribers were asked to use the prototype for 4 of the scenarios and their usual system for the other 4. Time on task, number of clicks, and order details were captured. User satisfaction was measured using posttask ratings and a validated system usability scale. The study participants practiced in 2 health systems\u27 outpatient practices. Usability tests were conducted between April and October of 2017. Main Outcomes and Measures: Usability (efficiency, error rate, and satisfaction) of indications-based computerized provider order entry prototype vs the electronic prescribing interface of 2 electronic health record vendors. Results: Thirty-two participants (17 attending physicians, 13 residents, and 2 physician assistants) used the prototype to complete 256 usability test scenarios. The mean (SD) time on task was 1.78 (1.17) minutes. For the 20 participants who used vendor 1\u27s system, it took a mean (SD) of 3.37 (1.90) minutes to complete a prescription, and for the 12 participants using vendor 2\u27s system, it took a mean (SD) of 2.93 (1.52) minutes. Across all scenarios, when comparing number of clicks, for those participants using the prototype and vendor 1, there was a statistically significant difference from the mean (SD) number of clicks needed (18.39 [12.62] vs 46.50 [27.29]; difference, 28.11; 95% CI, 21.47-34.75; P \u3c .001). For those using the prototype and vendor 2, there was also a statistically significant difference in number of clicks (20.10 [11.52] vs 38.25 [19.77]; difference, 18.14; 95% CI, 11.59-24.70; P \u3c .001). A blinded review of the order details revealed medication errors (eg, drug-allergy interactions) in 38 of 128 prescribing sessions using a vendor system vs 7 of 128 with the prototype. Conclusions and Relevance: Reengineering prescribing to start with the drug indication allowed indications to be captured in an easy and useful way, which may be associated with saved time and effort, reduced medication errors, and increased clinician satisfaction

    Comparison of a prototype for indications-based prescribing with 2 commercial prescribing systems

    Get PDF
    Importance: The indication (reason for use) for a medication is rarely included on prescriptions despite repeated recommendations to do so. One barrier has been the way existing electronic prescribing systems have been designed. Objective: To evaluate, in comparison with the prescribing modules of 2 leading electronic health record prescribing systems, the efficiency, error rate, and satisfaction with a new computerized provider order entry prototype for the outpatient setting that allows clinicians to initiate prescribing using the indication. Design, Setting, and Participants: This quality improvement study used usability tests requiring internal medicine physicians, residents, and physician assistants to enter prescriptions electronically, including indication, for 8 clinical scenarios. The tool order assignments were randomized and prescribers were asked to use the prototype for 4 of the scenarios and their usual system for the other 4. Time on task, number of clicks, and order details were captured. User satisfaction was measured using posttask ratings and a validated system usability scale. The study participants practiced in 2 health systems\u27 outpatient practices. Usability tests were conducted between April and October of 2017. Main Outcomes and Measures: Usability (efficiency, error rate, and satisfaction) of indications-based computerized provider order entry prototype vs the electronic prescribing interface of 2 electronic health record vendors. Results: Thirty-two participants (17 attending physicians, 13 residents, and 2 physician assistants) used the prototype to complete 256 usability test scenarios. The mean (SD) time on task was 1.78 (1.17) minutes. For the 20 participants who used vendor 1\u27s system, it took a mean (SD) of 3.37 (1.90) minutes to complete a prescription, and for the 12 participants using vendor 2\u27s system, it took a mean (SD) of 2.93 (1.52) minutes. Across all scenarios, when comparing number of clicks, for those participants using the prototype and vendor 1, there was a statistically significant difference from the mean (SD) number of clicks needed (18.39 [12.62] vs 46.50 [27.29]; difference, 28.11; 95% CI, 21.47-34.75; P \u3c .001). For those using the prototype and vendor 2, there was also a statistically significant difference in number of clicks (20.10 [11.52] vs 38.25 [19.77]; difference, 18.14; 95% CI, 11.59-24.70; P \u3c .001). A blinded review of the order details revealed medication errors (eg, drug-allergy interactions) in 38 of 128 prescribing sessions using a vendor system vs 7 of 128 with the prototype. Conclusions and Relevance: Reengineering prescribing to start with the drug indication allowed indications to be captured in an easy and useful way, which may be associated with saved time and effort, reduced medication errors, and increased clinician satisfaction

    Utilizing RxNorm to Support Practical Computing Applications: Capturing Medication History in Live Electronic Health Records

    Full text link
    RxNorm was utilized as the basis for direct-capture of medication history data in a live EHR system deployed in a large, multi-state outpatient behavioral healthcare provider in the United States serving over 75,000 distinct patients each year across 130 clinical locations. This tool incorporated auto-complete search functionality for medications and proper dosage identification assistance. The overarching goal was to understand if and how standardized terminologies like RxNorm can be used to support practical computing applications in live EHR systems. We describe the stages of implementation, approaches used to adapt RxNorm's data structure for the intended EHR application, and the challenges faced. We evaluate the implementation using a four-factor framework addressing flexibility, speed, data integrity, and medication coverage. RxNorm proved to be functional for the intended application, given appropriate adaptations to address high-speed input/output (I/O) requirements of a live EHR and the flexibility required for data entry in multiple potential clinical scenarios. Future research around search optimization for medication entry, user profiling, and linking RxNorm to drug classification schemes holds great potential for improving the user experience and utility of medication data in EHRs.Comment: Appendix (including SQL/DDL Code) available by author request. Keywords: RxNorm; Electronic Health Record; Medication History; Interoperability; Unified Medical Language System; Search Optimizatio

    CAMMD: Context Aware Mobile Medical Devices

    Get PDF
    Telemedicine applications on a medical practitioners mobile device should be context-aware. This can vastly improve the effectiveness of mobile applications and is a step towards realising the vision of a ubiquitous telemedicine environment. The nomadic nature of a medical practitioner emphasises location, activity and time as key context-aware elements. An intelligent middleware is needed to effectively interpret and exploit these contextual elements. This paper proposes an agent-based architectural solution called Context-Aware Mobile Medical Devices (CAMMD). This framework can proactively communicate patient records to a portable device based upon the active context of its medical practitioner. An expert system is utilised to cross-reference the context-aware data of location and time against a practitioners work schedule. This proactive distribution of medical data enhances the usability and portability of mobile medical devices. The proposed methodology alleviates constraints on memory storage and enhances user interaction with the handheld device. The framework also improves utilisation of network bandwidth resources. An experimental prototype is presented highlighting the potential of this approach

    Improving Usability and Adoption of Tablet-based Electronic Health Record (EHR) Applications

    Get PDF
    abstract: The technological revolution has caused the entire world to migrate to a digital environment and health care is no exception to this. Electronic Health Records (EHR) or Electronic Medical Records (EMR) are the digital repository for health data of patients. Nation wide efforts have been made by the federal government to promote the usage of EHRs as they have been found to improve quality of health service. Although EHR systems have been implemented almost everywhere, active use of EHR applications have not replaced paper documentation. Rather, they are often used to store transcribed data from paper documentation after each clinical procedure. This process is found to be prone to errors such as data omission, incomplete data documentation and is also time consuming. This research aims to help improve adoption of real-time EHRs usage while documenting data by improving the usability of an iPad based EHR application that is used during resuscitation process in the intensive care unit. Using Cognitive theories and HCI frameworks, this research identified areas of improvement and customizations in the application that were required to exclusively match the work flow of the resuscitation team at the Mayo Clinic. In addition to this, a Handwriting Recognition Engine (HRE) was integrated into the application to support a stylus based information input into EHR, which resembles our target users’ traditional pen and paper based documentation process. The EHR application was updated and then evaluated with end users at the Mayo clinic. The users found the application to be efficient, usable and they showed preference in using this application over the paper-based documentation.Dissertation/ThesisMasters Thesis Computer Science 201

    IMPROVING PCS 5.67 MEDITECH’S USER INTERFACE BY ADDING A “ONE-CLICK-ONE-SCREEN” ELECTRONIC PAGE

    Get PDF
    Medical organizations and physicians have been encouraged to implement different EHR systems. Initially these systems aimed to record, and store clinical data and improve its access and legibility. However, as these systems have become almost indispensable, users are demanding from these applications more complex tasks. Small practices and/or rural medical organizations often cannot afford to continuously upgrade their EHR systems or acquire modern systems. Research has shown that one way to solve this problem is to customize and add features that can facilitate user navigation. The purpose of this QI project was to investigate if integrating a “one-click-one-screen” electronic window displaying a snapshot of the most relevant and up-to-date patient information into PCS 5.67 Meditech was able to facilitate and improve data accessibility, information exchange, user satisfaction, patient care, and communication among the users. A pre-survey, given to 30 frequent users of PCS 5.67 Meditech, gathered their perception of the system’s UI. A “one-click one-screen” feature was designed however it was difficult to integrate it into the system’s UI because customization of this EHR system was complex beyond the local IT expertice. Nonetheless, the pre-survey data indicated that a significant number of PCS 5.67 Meditech users were dissatisfied with the performance of this EHR system. Additionally, the pre-survey data showed that the EHR system UI did not display clinical data in an efficient and user-friendly manner

    M-health review: joining up healthcare in a wireless world

    Get PDF
    In recent years, there has been a huge increase in the use of information and communication technologies (ICT) to deliver health and social care. This trend is bound to continue as providers (whether public or private) strive to deliver better care to more people under conditions of severe budgetary constraint