56 research outputs found
Standard versus short stem cemented Exeter<sup>®</sup> when used for primary total hip arthroplasty:a survivorship analysis
Aims: The aims were to compare the survival of the cemented standard (150 mm) with the short (DDH [35.5 mm offset or less], number 1 short stem [125 mm options of 37.5 mm, 44 mm, 50 mm offset] and revision [44/00/125]) Exeter ® V40 femoral stems when used for primary total hip arthroplasty (THA). Methods: Patients were retrospectively identified from an arthroplasty database. A total of 664 short stem Exeter ® variants were identified, of which 229 were DDH stems, 208 number 1 stems and 227 revision stems were implanted between 2011 and 2020. A control group of 698 standard Exeter ® stems used for THA was set up, and were followed up for a minimum of 10 years follow-up (implanted 2011). All-cause survival was assessed for THA and for the stem only. Adjusted analysis was undertaken for age, sex and ASA grade. Results: The median survival time for the short stems varied according to design: DDH had a survival time of 6.7 years, number 1 stems 4.1 years, and revision stems 7.2 years. Subjects in the short stem group (n = 664) were significantly younger (mean difference 5.1, P < 0.001) and were more likely to be female (odds ratio 1.89, 95% CI 1.50 to 2.39, P < 0.001), compared to the standard group. There were no differences in THA (P = 0.26) or stem (P = 0.35) survival at 5 years (adjusted THA: 98.3% vs. 97.2%; stem 98.7% vs. 97.8%) or 10 years (adjusted THA 97.0% vs. 96.0 %; stem 96.7% vs. 96.2%) between standard and short stem groups, respectively. At 5 years no differences were found in THA (DDH: 96.7%, number 1 97.5%, revision 97.3%, standard 98.6%) or stem (DDH: 97.6%, number 1 99.0%, revision 97.3%, standard 98.2%) survival between/among the different short stems or when compared to the standard group. Conclusion: The Exeter ® short stems offer equivocal survival when compared to the standard stem at 5- to 10-year follow-up, which does not seem to be influenced by the short stem design.</p
Design-related risk factors for revision of primary cemented stems: Analysis of 3 common stems in the Swedish Hip Arthroplasty Register
Background and purpose Even small design variables of the femoral stem may influence the outcome of a hip arthroplasty. We investigated whether design-related factors play any role in the risk of non-aseptic revision of the 3 most frequently used primary cemented stem designs in the Swedish Hip Arthroplasty Register. Patients and methods We studied 71,184 primary cemented femoral stem implants (21,008 Exeter polished stems, 43,036 Lubinus SPII stems, and 7,140 Spectron EF Primary stems) that were inserted from 1999 through 2006. Design-specific characteristics were analyzed using separate Cox regression models that were adjusted for sex, age, diagnosis, incision, and number of operations (first vs. second). Results The crude revision rate varied between 0.8% (Lubinus SPII) and 1.4% (Spectron Primary). For the Exeter stem, the smallest femoral head diameter (22 mm) was associated with a higher risk of revision. No other design-specific parameters influenced the risk of revision of the Exeter stem. The smallest Lubinus stem size, a stem with extended neck length combined with a femoral head with increasing neck length, or the use of a cobalt-chromium head had a negative influence on the outcome. For the Spectron stem, the risk of revision was elevated for the smallest stem and for increasing offset calculated as the combined effect of high offset design and increasing neck length. Interpretation Overall revision rates were low, but for two of the stems studied design factors such as size and neck length or offset influenced the risk of non-aseptic revision
Cost-effectiveness analyses comparing cemented, cementless, hybrid and reverse hybrid fixation in total hip arthroplasty: a systematic overview and critical appraisal of the current evidence
Background: This study aims to present an overview and critical appraisal of all previous studies comparing costs and outcomes of the different modes of fixation in total hip arthroplasty (THA). A secondary aim is to provide conclusions regarding the most cost-effective mode of implant fixation per gender and age-specific population in THA, based on high quality studies.Methods: A systematic search was conducted to identify cost-effectiveness analyses (CEAs) comparing different modes of implant fixation in THA. Analysis of results was done with solely CEAs that had a high methodological quality.Results: A total of 12 relevant studies were identified and presented, of which 5 were considered to have the methodological rigor for inclusion in the analysis of results. These studies found that either cemented or hybrid fixation was the most cost-effective implant fixation mode for most age- and gender-specific subgroups.Conclusion: Currently available well performed CEAs generally support the use of cemented and hybrid fixation for all age-groups relevant for THA and both genders. However, these findings were mainly based on a single database and depended on assumptions made in the studies' methodology. Issues discussed in this paper have to be considered and future work is needed
Experience of an anatomic femoral stem in a UK orthopaedic centre beyond 20 years of follow-up
Introduction Increasing interest in the use of anatomical stems has developed as the prevalence of periprosthetic fractures (PPFs) continues to increase. The primary aim of this study was to determine the long-term survivorship and PPF rate of an anatomical femoral stem in a single UK centre. Patients and methods Between 2000 and 2002, 94 consecutive THAs were performed using the 170 mm Lubinus SP II anatomical femoral stem in our institution. Patient demographics, operative details and clinical outcomes were collected prospectively in an arthroplasty database. Patient records and national radiographic archives were reviewed finally at a mean of 21.5 years (SD 0.7) following surgery to identify occurrence of subsequent revision surgery, dislocation or periprosthetic fracture. Results Mean patient age at surgery was 65.8 years (SD 12.5, 34–88 years). There were 48 women (51%). Osteoarthritis was the operative indication in 88 patients (94%). Analysis of all-cause THA failure demonstrated a survivorship of 98.5% (95% confidence interval [CI], 98.0–99.3%) at 10 years and 96.7% (94.5–98.9%) at 21 years. The 20-year stem survival for aseptic loosening was 100% with no cases of significant lysis found (lucent line > 2 mm) and no stems required revision. Patient demographics did not appear to influence risk of revision (p > 0.05). There were 2 revisions in total (2 for acetabular loosening with original stems retained). There were no PPFs identified at mean 21.5 year follow-up and 5 dislocations (5%). Conclusions The Lubinus SP II 170 mm stem demonstrated excellent survivorship and negligible PPF rates over 20 years following primary THA.Peer reviewe
SPECT-CT metabolic and morphological study of 2 types of cemented hip stem prostheses in primary total hip arthroplasty patients
Background: Cemented hip arthroplasty requires applying a layer of polymethylmethacrylate (cement) in the space between the bone and the prosthetic stem. This can be achieved using 2 techniques: the thick-layer technique (requires a layer of at least 2 mm to surround an undersized prosthetic stem), and the thin-layer technique (requires a thin layer of cement, so that the prosthetic stem fills the femoral medullary canal). Both approaches have excellent long-term clinical and radiological outcomes, although an implant's insertion into the bone generates inevitable bone mass and bone metabolic changes around it. Combination of single photon emission computed tomography and computed tomography scan (SPECT-CT) imaging combines the single photon emission computed tomography's ability to provide detailed bone metabolism assessment with the computed tomography scan's capacity to provide a meticulous anatomical study. Methods: This is a single center, open label, randomized clinical trial, performed in the premises of the Bellvitge University Hospital. Participants will be randomly assigned to the Thick-layer technique group (Exeter V40 Cemented Femoral Stem) or to the French paradox technique group (Müller Straight Stem). All participants will have a SPECT-CT scan study at 3, 6, 12, and 24 months after the surgery. Discussion: Surgical distress itself and the implant's insertion into the bone may cause microvascular changes that alter periprosthetic bone mass and bone metabolism. To the best of our knowledge, there are no studies using SPECT-CT to compare bone metabolism evolution in the postoperative period between these 2 surgical cementation techniques. We aim to provide information in this regard that could help decision making in complicated implant cases and, maybe, pave the way for larger, and methodologically improved studies
The Olympia anatomic polished cemented stem is associated with a high survivorship, excellent hip-specific functional outcome, and high satisfaction levels:follow-up of 239 consecutive patients beyond 15 years
Introduction: The Olympia femoral stem is a stainless steel, anatomically shaped, polished and three-dimensionally tapered implant designed for use in cemented total hip arthroplasty (THA). The primary aim of this study was to determine the long-term survivorship, radiographic outcome, and patient-reported outcome measures (PROMs) of the Olympia stem. Patients and methods: Between May 2003 and December 2005, 239 patients (264 THAs) underwent a THA with an Olympia stem in our institution. Patient-reported outcome measures were assessed using the Oxford Hip Score (OHS), EuroQol-5 dimensions (EQ-5D) score, and patient satisfaction at mean 10 years following THA. Patient records and radiographs were then reviewed at a mean of 16.5 years (SD 0.7, 15.3–17.8) following THA to identify occurrence of complications or revision surgery for any cause following surgery. Radiographs were assessed for lucent lines and lysis according to Gruen’s zones Results: Mean patient age at surgery was 68.0 years (SD 10.9, 31–93 years). There were 156 women (65%, 176 THAs). Osteoarthritis was the indication for THA in 204 patients (85%). All cause stem survivorship at 10 years was 99.2% (95% confidence interval [CI], 97.9%–100%) and at 15 years was 97.5% (94.6%–100%). The 15-year stem survival for aseptic loosening was 100%. Analysis of all-cause THA failure demonstrated a survivorship of 98.5% (96.3%–100%) at 10 years and 95.9% (92.4%–99.4%) at 15 years. There were 9 THAs with non-progressive lucent lines in a single Gruen zone and 3 had lines in two zones, and no patient demonstrated signs for lysis. At a mean of 10-year (SD 0.8, 8.7–11.3) follow-up, mean OHS was 39 (SD 10.3, range 7–48) and 94% of patients reported being very satisfied or satisfied with their THA. Conclusions: The Olympia stem demonstrated excellent 10-year PROMs and very high rates of stem survivorship at final follow-up beyond 15 years
Implant survival of the most common cemented total hip devices from the Nordic Arthroplasty Register Association database
Background and purpose According to previous Nordic Arthroplasty Register Association (NARA) data, the 10-year implant survival of cemented total hip arthroplasties (THAs) is 94% in patients aged 65-74 and 96% in patients aged 75 or more. Here we report a brand-level comparison of cemented THA based on the NARA database, which has not been done previously.Patients and methods We determined the rate of implant survival of the 9 most common cemented THAs in the NARA database. We used Kaplan-Meier analysis with 95% CI to study implant survival at 10 and 15 years, and Cox multiple regression to assess survival and hazard ratios (HRs), with revision for any reason as endpoint and with adjustment for age, sex, diagnosis, and femoral head material.Results Spectron EF THA (89.9% (CI: 89.3-90.5)) and Elite THA (89.8% (CI: 89.0-90.6)) had the lowest 10-year survivorship. Lubinus (95.7% survival, CI: 95.5-95.9), MS 30 (96.6%, CI: 95.8-97.4), and C-stem THA (95.8%, CI: 94.8-96.8) had a 10-year survivorship of at least 95%. Lubinus (revision risk (RR)=0.77, CI: 0.73-0.81), Muller (RR =0.83, CI: 0.70-0.99), MS-30 (RR =0.73, CI: 0.63-0.86), C-stem (RR =0.70, CI: 0.55-0.90), and Exeter Duration THA (RR =0.84, CI: 0.77-0.90) had a lower risk of revision than Charnley THA, the reference implant.Interpretation The Spectron EF THA and the Elite THA had a lower implant survival than the Charnley, Exeter, and Lubinus THAs. Implant survival of the Muller, MS 30, CPT, and C-stem THAs was above the acceptable limit for 10-year survival
Implant survival of the most common cemented total hip devices from the Nordic Arthroplasty Register Association database
Background and purpose According to previous Nordic Arthroplasty Register Association (NARA) data, the 10-year implant survival of cemented total hip arthroplasties (THAs) is 94% in patients aged 65-74 and 96% in patients aged 75 or more. Here we report a brand-level comparison of cemented THA based on the NARA database, which has not been done previously.Patients and methods We determined the rate of implant survival of the 9 most common cemented THAs in the NARA database. We used Kaplan-Meier analysis with 95% CI to study implant survival at 10 and 15 years, and Cox multiple regression to assess survival and hazard ratios (HRs), with revision for any reason as endpoint and with adjustment for age, sex, diagnosis, and femoral head material.Results Spectron EF THA (89.9% (CI: 89.3-90.5)) and Elite THA (89.8% (CI: 89.0-90.6)) had the lowest 10-year survivorship. Lubinus (95.7% survival, CI: 95.5-95.9), MS 30 (96.6%, CI: 95.8-97.4), and C-stem THA (95.8%, CI: 94.8-96.8) had a 10-year survivorship of at least 95%. Lubinus (revision risk (RR)=0.77, CI: 0.73-0.81), Muller (RR =0.83, CI: 0.70-0.99), MS-30 (RR =0.73, CI: 0.63-0.86), C-stem (RR =0.70, CI: 0.55-0.90), and Exeter Duration THA (RR =0.84, CI: 0.77-0.90) had a lower risk of revision than Charnley THA, the reference implant.Interpretation The Spectron EF THA and the Elite THA had a lower implant survival than the Charnley, Exeter, and Lubinus THAs. Implant survival of the Muller, MS 30, CPT, and C-stem THAs was above the acceptable limit for 10-year survival.Peer reviewe
- …
