906,846 research outputs found
MonALISA : A Distributed Monitoring Service Architecture
The MonALISA (Monitoring Agents in A Large Integrated Services Architecture)
system provides a distributed monitoring service. MonALISA is based on a
scalable Dynamic Distributed Services Architecture which is designed to meet
the needs of physics collaborations for monitoring global Grid systems, and is
implemented using JINI/JAVA and WSDL/SOAP technologies. The scalability of the
system derives from the use of multithreaded Station Servers to host a variety
of loosely coupled self-describing dynamic services, the ability of each
service to register itself and then to be discovered and used by any other
services, or clients that require such information, and the ability of all
services and clients subscribing to a set of events (state changes) in the
system to be notified automatically. The framework integrates several existing
monitoring tools and procedures to collect parameters describing computational
nodes, applications and network performance. It has built-in SNMP support and
network-performance monitoring algorithms that enable it to monitor end-to-end
network performance as well as the performance and state of site facilities in
a Grid. MonALISA is currently running around the clock on the US CMS test Grid
as well as an increasing number of other sites. It is also being used to
monitor the performance and optimize the interconnections among the reflectors
in the VRVS system.Comment: Talk from the 2003 Computing in High Energy and Nuclear Physics
(CHEP03), La Jolla, Ca, USA, March 2003, 8 pages, pdf. PSN MOET00
Sequential Testing with Uniformly Distributed Size
Sequential procedures of testing for structural stability do not provide enough guidance on the shape of boundaries that are used to decide on acceptance or rejection, requiring only that the overall size of the test is asymptotically controlled. We introduce and motivate a reasonable criterion for a shape of boundaries which requires that the test size be uniformly distributed over the testing period. Under this criterion, we numerically construct boundaries for most popular sequential tests that are characterized by a test statistic behaving asymptotically either as a Wiener process or Brownian bridge. We handle this problem both in a context of retrospecting a historical sample and in a context of monitoring newly arriving data. We tabulate the boundaries by Â…tting them to certain exible but parsimonious functional forms. Interesting patterns emerge in an illustrative application of sequential tests to the Phillips curve model.Structural stability; sequential tests; CUSUM; retrospection; monitoring; boundaries; asymptotic size
Scalability tests of R-GMA-based grid job monitoring system for CMS Monte Carlo data production
Copyright @ 2004 IEEEHigh-energy physics experiments, such as the compact muon solenoid (CMS) at the large hadron collider (LHC), have large-scale data processing computing requirements. The grid has been chosen as the solution. One important challenge when using the grid for large-scale data processing is the ability to monitor the large numbers of jobs that are being executed simultaneously at multiple remote sites. The relational grid monitoring architecture (R-GMA) is a monitoring and information management service for distributed resources based on the GMA of the Global Grid Forum. We report on the first measurements of R-GMA as part of a monitoring architecture to be used for batch submission of multiple Monte Carlo simulation jobs running on a CMS-specific LHC computing grid test bed. Monitoring information was transferred in real time from remote execution nodes back to the submitting host and stored in a database. In scalability tests, the job submission rates supported by successive releases of R-GMA improved significantly, approaching that expected in full-scale production
Distributed State Estimation With Phasor Measurement Units (Pmu) For Power Systems
Wide-area monitoring for the power system is a key tool for preventing the power system from system wide failure. State Estimation (SE) is an essential and practical monitoring tool that has been widely used to provide estimated values for each quantity within energy management systems (EMS) in the control center. However, monitoring larger power systems coordinated by regional transmission operators has placed an enormous operational burden on current SE techniques. A distributed state estimation (DSE) algorithm with a hierarchical structure designed for the power system industry is much more computationally efficient and robust especially for monitoring a wide-area power system. Moreover, considering the deregulation of the power system industry, this method does not require sensitive data exchange between smaller areas that may be competing entities. The use of phasor measurement units (PMUs) in the SE algorithm has proven to improve the performance in terms of accuracy and converging speed. Being able to synchronize the measurements between different areas, PMUs are perfectly suited for distributed state estimation. This dissertation investigates the benefits of the DSE using PMU over a serial state estimator in wide area monitoring. A new method has been developed using available PMU data to calculate the reference angle differences between decomposed power systems in various situations, such as when the specific PMU data of the global slack bus cannot be obtained. The algorithms were tested on six bus, I standard 30 bus and I 118-bus test cases. The proposed distributed state estimator has also been implemented in a test bed to work with a power system real-time digital simulator (RTDS) that simulates the physical power system. PMUs made by SEL and GE are used to provide real-time inputs to the distributed state estimator. Simulation results demonstrated the benefits of the PMU and distributed SE techniques. Additionally a constructed test bed verified and validated the proposed algorithms and can be used for different smart grid tests
Field testing of modular borehole monitoring with simultaneous distributed acoustic sensing and geophone vertical seismic profiles at Citronelle, Alabama
A modular borehole monitoring concept has been implemented to provide a suite of well-based monitoring tools that can be deployed cost effectively in a flexible and robust package. The initial modular borehole monitoring system was deployed as part of a CO2 injection test operated by the Southeast Regional Carbon Sequestration Partnership near Citronelle, Alabama. The Citronelle modular monitoring system transmits electrical power and signals, fibre-optic light pulses, and fluids between the surface and a reservoir. Additionally, a separate multi-conductor tubing-encapsulated line was used for borehole geophones, including a specialized clamp for casing clamping with tubing deployment. The deployment of geophones and fibre-optic cables allowed comparison testing of distributed acoustic sensing. We designed a large source effort (>64 sweeps per source point) to test fibre-optic vertical seismic profile and acquired data in 2013. The native measurement in the specific distributed acoustic sensing unit used (an iDAS from Silixa Ltd) is described as a localized strain rate. Following a processing flow of adaptive noise reduction and rebalancing the signal to dimensionless strain, improvement from repeated stacking of the source was observed. Conversion of the rebalanced strain signal to equivalent velocity units, via a scaling by local apparent velocity, allows quantitative comparison of distributed acoustic sensing and geophone data in units of velocity. We see a very good match of uncorrelated time series in both amplitude and phase, demonstrating that velocity-converted distributed acoustic sensing data can be analyzed equivalent to vertical geophones. We show that distributed acoustic sensing data, when averaged over an interval comparable to typical geophone spacing, can obtain signal-to-noise ratios of 18 dB to 24 dB below clamped geophones, a result that is variable with noise spectral amplitude because the noise characteristics are not identical. With vertical seismic profile processing, we demonstrate the effectiveness of downgoing deconvolution from the large spatial sampling of distributed acoustic sensing data, along with improved upgoing reflection quality. We conclude that the extra source effort currently needed for tubing-deployed distributed acoustic sensing vertical seismic profile, as part of a modular monitoring system, is well compensated by the extra spatial sampling and lower deployment cost as compared with conventional borehole geophones
- …