11,552 research outputs found
Recognition of elementary arm movements using orientation of a tri-axial accelerometer located near the wrist
In this paper we present a method for recognising three fundamental movements of the human arm (reach and retrieve, lift cup to mouth, rotation of the arm) by determining the orientation of a tri-axial accelerometer located near the wrist. Our objective is to detect the occurrence of such movements performed with the impaired arm of a stroke patient during normal daily activities as a means to assess their rehabilitation. The method relies on accurately mapping transitions of predefined, standard orientations of the accelerometer to corresponding elementary arm movements. To evaluate the technique, kinematic data was collected from four healthy subjects and four stroke patients as they performed a number of activities involved in a representative activity of daily living, 'making-a-cup-of-tea'. Our experimental results show that the proposed method can independently recognise all three of the elementary upper limb movements investigated with accuracies in the range 91–99% for healthy subjects and 70–85% for stroke patients
Prototyping a Capacitive Sensing Device for Gesture Recognition
Capacitive sensing is a technology that can detect proximity and touch. It can also be utilized to measure position and acceleration of gesture motions. This technology has many applications, such as replacing mechanical buttons in a gaming device interface, detecting respiration rate without direct contact with the skin, and providing gesture sensing capability for rehabilitation devices. In this thesis, an approach to prototype a capacitive gesture sensing device using the Eagle PCB design software is demonstrated. In addition, this paper tested and evaluated the resulting prototype device, validating the effectiveness of the approach
Recognition of elementary upper limb movements in an activity of daily living using data from wrist mounted accelerometers
In this paper we present a methodology as a proof of concept for recognizing fundamental movements of the humanarm (extension, flexion and rotation of the forearm) involved in ‘making-a-cup-of-tea’, typical of an activity of daily-living (ADL). The movements are initially performed in a controlled environment as part of a training phase and the data are grouped into three clusters using k-means clustering. Movements performed during ADL, forming part of the testing phase, are associated with each cluster label using a minimum distance classifier in a multi-dimensional feature space, comprising of features selected from a ranked set of 30 features, using Euclidean and Mahalonobis distance as the metric. Experiments were performed with four healthy subjects and our results show that the proposed methodology can detect the three movements with an overall average accuracy of 88% across all subjects and arm movement types using Euclidean distance classifier
A flexible sensor technology for the distributed measurement of interaction pressure
We present a sensor technology for the measure of the physical human-robot interaction pressure developed in the last years at Scuola Superiore Sant'Anna. The system is composed of flexible matrices of opto-electronic sensors covered by a soft silicone cover. This sensory system is completely modular and scalable, allowing one to cover areas of any sizes and shapes, and to measure different pressure ranges. In this work we present the main application areas for this technology. A first generation of the system was used to monitor human-robot interaction in upper- (NEUROExos; Scuola Superiore Sant'Anna) and lower-limb (LOPES; University of Twente) exoskeletons for rehabilitation. A second generation, with increased resolution and wireless connection, was used to develop a pressure-sensitive foot insole and an improved human-robot interaction measurement systems. The experimental characterization of the latter system along with its validation on three healthy subjects is presented here for the first time. A perspective on future uses and development of the technology is finally drafted
Measurements by A LEAP-Based Virtual Glove for the hand rehabilitation
Hand rehabilitation is fundamental after stroke or surgery. Traditional rehabilitation
requires a therapist and implies high costs, stress for the patient, and subjective evaluation of
the therapy effectiveness. Alternative approaches, based on mechanical and tracking-based gloves,
can be really effective when used in virtual reality (VR) environments. Mechanical devices are often
expensive, cumbersome, patient specific and hand specific, while tracking-based devices are not
affected by these limitations but, especially if based on a single tracking sensor, could suffer from
occlusions. In this paper, the implementation of a multi-sensors approach, the Virtual Glove (VG),
based on the simultaneous use of two orthogonal LEAP motion controllers, is described. The VG is
calibrated and static positioning measurements are compared with those collected with an accurate
spatial positioning system. The positioning error is lower than 6 mm in a cylindrical region of interest
of radius 10 cm and height 21 cm. Real-time hand tracking measurements are also performed, analysed
and reported. Hand tracking measurements show that VG operated in real-time (60 fps), reduced
occlusions, and managed two LEAP sensors correctly, without any temporal and spatial discontinuity
when skipping from one sensor to the other. A video demonstrating the good performance of VG
is also collected and presented in the Supplementary Materials. Results are promising but further
work must be done to allow the calculation of the forces exerted by each finger when constrained by
mechanical tools (e.g., peg-boards) and for reducing occlusions when grasping these tools. Although
the VG is proposed for rehabilitation purposes, it could also be used for tele-operation of tools and
robots, and for other VR applications
Tactile-STAR: A Novel Tactile STimulator And Recorder System for Evaluating and Improving Tactile Perception
Many neurological diseases impair the motor and somatosensory systems. While several different technologies are used in clinical practice to assess and improve motor functions, somatosensation is evaluated subjectively with qualitative clinical scales. Treatment of somatosensory deficits has received limited attention. To bridge the gap between the assessment and training of motor vs. somatosensory abilities, we designed, developed, and tested a novel, low-cost, two-component (bimanual) mechatronic system targeting tactile somatosensation: the Tactile-STAR—a tactile stimulator and recorder. The stimulator is an actuated pantograph structure driven by two servomotors, with an end-effector covered by a rubber material that can apply two different types of skin stimulation: brush and stretch. The stimulator has a modular design, and can be used to test the tactile perception in different parts of the body such as the hand, arm, leg, big toe, etc. The recorder is a passive pantograph that can measure hand motion using two potentiometers. The recorder can serve multiple purposes: participants can move its handle to match the direction and amplitude of the tactile stimulator, or they can use it as a master manipulator to control the tactile stimulator as a slave. Our ultimate goal is to assess and affect tactile acuity and somatosensory deficits. To demonstrate the feasibility of our novel system, we tested the Tactile-STAR with 16 healthy individuals and with three stroke survivors using the skin-brush stimulation. We verified that the system enables the mapping of tactile perception on the hand in both populations. We also tested the extent to which 30 min of training in healthy individuals led to an improvement of tactile perception. The results provide a first demonstration of the ability of this new system to characterize tactile perception in healthy individuals, as well as a quantification of the magnitude and pattern of tactile impairment in a small cohort of stroke survivors. The finding that short-term training with Tactile-STARcan improve the acuity of tactile perception in healthy individuals suggests that Tactile-STAR may have utility as a therapeutic intervention for somatosensory deficits
Recommended from our members
Assessing plantar sensation in the foot using the FOot Roughness Discrimination Test (FoRDT™): a reliability and validity study in stroke
BACKGROUND: The foot sole represents a sensory dynamometric map and is essential for balance and gait control. Sensory impairments are common, yet often difficult to quantify in neurological conditions, particularly stroke. A functionally oriented and quantifiable assessment, the Foot Roughness Discrimination Test (FoRDT™), was developed to address these shortcomings. OBJECTIVE: To evaluate inter- and intra-rater reliability, convergent and discriminant validity of the Foot Roughness Discrimination Test (FoRDT™). DESIGN: Test-retest design. SETTING: Hospital Outpatient. PARTICIPANTS: Thirty-two people with stroke (mean age 70) at least 3 months after stroke, and 32 healthy, age-matched controls (mean age 70). MAIN OUTCOME MEASURES: Roughness discrimination thresholds were quantified utilising acrylic foot plates, laser-cut to produce graded spatial gratings. Stroke participants were tested on three occasions, and by two different raters. Inter- and intra-rater reliability and agreement were evaluated with Intraclass Correlation Coefficients and Bland-Altman plots. Convergent validity was evaluated through Spearman rank correlation coefficients (rho) between the FoRDT™ and the Erasmus modified Nottingham Sensory Assessment (EmNSA). RESULTS: Intra- and inter rater reliability and agreement were excellent (ICC =.86 (95% CI .72-.92) and .90 (95% CI .76 -.96)). Discriminant validity was demonstrated through significant differences in FoRDT™ between stroke and control participants (p.05). CONCLUSIONS: This simple and functionally oriented test of plantar sensation is reliable, valid and clinically feasible for use in an ambulatory, chronic stroke and elderly population. It offers clinicians and researchers a sensitive and robust sensory measure and may further support the evaluation of rehabilitation targeting foot sensation. This article is protected by copyright. All rights reserved
- …