7,135 research outputs found
Slow dynamics and aging of a confined granular flow
We present experimental results on slow flow properties of a granular
assembly confined in a vertical column and driven upwards at a constant
velocity V. For monodisperse assemblies this study evidences at low velocities
() a stiffening behaviour i.e. the stress necessary to obtain
a steady sate velocity increases roughly logarithmically with velocity. On the
other hand, at very low driving velocity (), we evidence a
discontinuous and hysteretic transition to a stick-slip regime characterized by
a strong divergence of the maximal blockage force when the velocity goes to
zero. We show that all this phenomenology is strongly influenced by surrounding
humidity. We also present a tentative to establish a link between the granular
rheology and the solid friction forces between the wall and the grains. We base
our discussions on a simple theoretical model and independent grain/wall
tribology measurements. We also use finite elements numerical simulations to
confront experimental results to isotropic elasticity. A second system made of
polydisperse assemblies of glass beads is investigated. We emphasize the onset
of a new dynamical behavior, i.e. the large distribution of blockage forces
evidenced in the stick-slip regime
Development of a dynamic virtual reality model of the inner ear sensory system as a learning and demonstrating tool
In order to keep track of the position and motion of our body in space, nature has given us a fascinating and very ingenious organ, the inner ear. Each inner ear includes five biological sensors - three angular and two linear accelerometers - which provide the body with the ability to sense angular and linear motion of the head with respect to inertial space. The aim of this paper is to present a dynamic virtual reality model of these sensors. This model, implemented in Matlab/Simulink, simulates the rotary chair testing which is one of the tests carried out during a diagnosis of the vestibular system. High-quality 3D-animations linked to the Simulink model are created using the export of CAD models into Virtual Reality Modeling Language (VRML) files. This virtual environment shows not only the test but also the state of each sensor (excited or inhibited) in real time. Virtual reality is used as a tool of integrated learning of the dynamic behavior of the inner ear using ergonomic paradigm of user interactivity (zoom, rotation, mouse interaction,…). It can be used as a learning and demonstrating tool either in the medicine field - to understand the behavior of the sensors during any kind of motion - or in the aeronautical field to relate the inner ear functioning to some sensory illusions
Review of research in feature-based design
Research in feature-based design is reviewed. Feature-based design is regarded as a key factor towards CAD/CAPP integration from a process planning point of view. From a design point of view, feature-based design offers possibilities for supporting the design process better than current CAD systems do. The evolution of feature definitions is briefly discussed. Features and their role in the design process and as representatives of design-objects and design-object knowledge are discussed. The main research issues related to feature-based design are outlined. These are: feature representation, features and tolerances, feature validation, multiple viewpoints towards features, features and standardization, and features and languages. An overview of some academic feature-based design systems is provided. Future research issues in feature-based design are outlined. The conclusion is that feature-based design is still in its infancy, and that more research is needed for a better support of the design process and better integration with manufacturing, although major advances have already been made
NASA Lewis 8 by 6 foot supersonic wind tunnel
Performance data are presented for the tunnel, which has a Mach number range from 0.36 to 2.0. The tunnel circuit, test section, model support systems, auxiliary systems, instrumentation, control room equipment, and automatic recording and computing equipment are also described. Information is presented on criteria for designing models and on shop facilities available to prospective users
Capillary Condensation, Freezing, and Melting in Silica Nanopores: A Sorption Isotherm and Scanning Calorimetry Study on Nitrogen in Mesoporous SBA-15
Condensation, melting and freezing of nitrogen in a powder of mesoporous
silica grains (SBA-15) has been studied by combined volumetric sorption
isotherm and scanning calorimetry measurements. Within the mean field model of
Saam and Cole for vapor condensation in cylindrical pores a liquid nitrogen
sorption isotherm is well described by a bimodal pore radius distribution. It
encompasses a narrow peak centered at 3.3 nm, typical of tubular mesopores, and
a significantly broader peak characteristic of micropores, located at 1 nm. The
material condensed in the micropores as well as the first two adsorbed
monolayers in the mesopores do not exhibit any caloric anomaly. The
solidification and melting transformation affects only the pore condensate
beyond approx. the second monolayer of the mesopores. Here, interfacial melting
leads to a single peak in the specific heat measurements. Homogeneous and
heterogeneous freezing along with a delayering transition for partial fillings
of the mesopores result in a caloric freezing anomaly similarly complex and
dependent on the thermal history as has been observed for argon in SBA-15. The
axial propagation of the crystallization in pore space is more effective in the
case of nitrogen than previously observed for argon, which we attribute to
differences in the crystalline textures of the pore solids.Comment: 10 pages, 7 figure
Preparative electrophoresis for space
A premise of continuous flow electrophoresis is that removal of buoyance-induced thermal convection caused by axial and lateral temperature gradients results in ideal performance of these instruments in space. Although these gravity dependent phenomena disturb the rectilinear flow in the separation chamber when high voltage gradients or thick chamber are used, distortion of the injected sample stream due to electrodynamic effects cause major broadening of the separated bands. The electrophoresis separation process is simple, however flow local to the sample filament produced by the applied electric field were not considered. These electrohydrodynamic flows distort the sample stream and limit the separation. Also, electroosmosis and viscous flow combine to further distort the process. A moving wall concept is being proposed for space which will eliminate and control the disturbances. The moving wall entrains the fluid to move as a rigid body and produces a constant residence time for all samples distributed across the chamber thickness. The moving wall electrophoresis chamber can only be operated in space because there is no viscous flow in the chamber to stabilize against thermal convection
Structural design of a vertical antenna boresight 18.3 by 18.3-m planar near-field antenna measurement system
A large very precise near-field planar scanner was proposed for NASA Lewis Research Center. This scanner would permit near-field measurements over a horizontal scan plane measuring 18.3 m by 18.3 m. Large aperture antennas mounted with antenna boresight vertical could be tested up to 60 GHz. When such a large near field scanner is used for pattern testing, the antenna or antenna system under test does not have to be moved. Hence, such antennas and antenna systems can be positioned and supported to simulate configuration in zero g. Thus, very large and heavy machinery that would be needed to accurately move the antennas are avoided. A preliminary investigation was undertaken to address the mechanical design of such a challenging near-field antenna scanner. The configuration, structural design and results of a parametric NASTRAN structural optimization analysis are contained. Further, the resulting design was dynamically analyzed in order to provide resonant frequency information to the scanner mechanical drive system designers. If other large near field scanners of comparable dimensions are to be constructed, the information can be used for design optimization of these also
Polymorphism of the glass former ethanol confined in mesoporous silicon
X-ray diffraction patterns of ethanol confined in parallel-aligned channels
of approx. 10 nm diameter and 50 micrometer length in mesoporous silicon have
been recorded as a function of filling fraction, temperature and for varying
cooling and heating rates. A sorption isotherm, recorded in the liquid state,
indicates a three monolayer thick, strongly adsorbed wall layer and a capillary
condensed fraction of molecules in the pore center. Though the strongly
adsorbed film remains in an amorphous state for the entire temperature range
investigated, the capillary condensed molecules reproduce the polymorphism of
bulk solid ethanol, that is the formation of either crystalline or glass-like
states as a function of cooling rate. The critical rate necessary to achieve a
vitrification in the mesopores is, however, at least two orders of magnitude
smaller than in the bulk state. This finding can be traced both to pure
geometrical constraints and quenched disorder effects, characteristic of
confinement in mesoporous silicon.Comment: 6 pages, 4 figure
Satellite power systems structures: A 1980 technology status review
The classes of major structural components and constructions utilized were considered. A review of the current (SPS) structure technology status was made. The major issues considered pertinent to SPS structures are: Cost effective construction, construction materials, structural design requirements, stress and dimensional integrity of as-built structures, and predictability of strength and dynamic behavior. The feasibility of passive figure control approach to MPTS flatness, of structure stiffness compatible with MPTS pointing, of passive control through damping, and the feasibility of space fabrication of ultra-large reflector surfaces are also considered. Qualification, model verification, inspection are considered of vital concern
- …