186,313 research outputs found

    Recent flow visualization studies in the 0.3-m TCT

    Get PDF
    Light beams are altered by refractive index changes; flow induced refractive index changes provide the impetus for conventional visualization techniques such as schlieren and shadowgraph. Unfortunately effects related to the flow can be masked by refractive index inhomogeneities external to the test section. A simple shadowgraph scheme was used to assess the flow quality of the Langley 0.3 meter Transonic Cryogenic Tunnel. When the penetration tubes were evacuated the quality of the shadowgraph improved dramatically

    Sonoluminescence as a QED vacuum effect. I: The Physical Scenario

    Get PDF
    Several years ago Schwinger proposed a physical mechanism for sonoluminescence in terms of changes in the properties of the quantum-electrodynamic (QED) vacuum state. This mechanism is most often phrased in terms of changes in the Casimir Energy: changes in the distribution of zero-point energies and has recently been the subject of considerable controversy. The present paper further develops this quantum-vacuum approach to sonoluminescence: We calculate Bogolubov coefficients relating the QED vacuum states in the presence of a homogeneous medium of changing dielectric constant. In this way we derive an estimate for the spectrum, number of photons, and total energy emitted. We emphasize the importance of rapid spatio-temporal changes in refractive indices, and the delicate sensitivity of the emitted radiation to the precise dependence of the refractive index as a function of wavenumber, pressure, temperature, and noble gas admixture. Although the physics of the dynamical Casimir effect is a universal phenomenon of QED, specific experimental features are encoded in the condensed matter physics controlling the details of the refractive index. This calculation places rather tight constraints on the possibility of using the dynamical Casimir effect as an explanation for sonoluminescence, and we are hopeful that this scenario will soon be amenable to direct experimental probes. In a companion paper we discuss the technical complications due to finite-size effects, but for reasons of clarity in this paper we confine attention to bulk effects.Comment: 25 pages, LaTeX 209, ReV-TeX 3.2, eight figures. Minor revisions: Typos fixed, references updated, minor changes in numerical estimates, minor changes in some figure

    Optimisation of distributed feedback laser biosensors

    Get PDF
    A new integrated optical sensor chip is proposed, based on a modified distributed- feedback (DFB) semiconductor laser. The semiconductor layers of different refractive indices that comprise a laser form the basis of a waveguide sensor, where changes in the refractive index of material at the surface are sensed via changes in the evanescent field of the lasing mode. In DFB lasers, laser oscillation occurs at the Bragg wavelength. Since this is sensitive to the effective refractive index of the optical mode, the emission wavelength is sensitive to the index of a sample on the waveguide surface. Hence, lasers are modelled as planar waveguides and the effective index of the fundamental transverse electric mode is calculated as a function of index and thickness of a thin surface layer using the beam propagation method. We find that an optimised structure has a thin upper cladding layer of ~0.15 mum, which according to this model gives detection limits on test layer index and thickness resolution of 0.1 and 1.57 nm, respectively, a figure which may be further improved using two lasers in an interferometer-type configuration

    SnO<sub>2</sub> nanoparticles in silica: nanosized tools for femtosecond-laser machining of refractive index patterns

    No full text
    We show that SnO2 nanoclusters in silica interact with ultrashort infrared laser pulses focused inside the material generating a hydrostatic compression and photoelastic response of the surrounding glass. This effect, together with the laser-induced nanocluster amorphization, gives rise to positive or negative refractive-index changes, up to 10–2, depending on the beam-power density. This result points out a wide tuning of the refractive index patterns obtainable in silica-based optical technology

    Refractive change following pseudophakic vitrectomy: a retrospective review

    Get PDF
    Background To assess the occurrence and magnitude of refractive change in pseudophakic eyes undergoing 20 gauge pars plana vitrectomy without scleral buckling and to investigate possible aetiological factors. Methods Retrospective case note review of 87 pseudophakic eyes undergoing 20 gauge pars plana vitrectomy for a variety of vitreo-retinal conditions over a three-year period. Anterior chamber depth (ACD) was measured before and after vitrectomy surgery in 32 eyes. Forty-three pseudophakic fellow eyes were used as controls. Results Eighty-seven eyes (84 patients) were included in the study. Mean spherical equivalent refraction prior to vitrectomy was -0.20 dioptres, which changed to a mean of -0.65 dioptres postoperatively (standard deviation of refractive change 0.59, range-2.13 to 0.75 dioptres) (p < 0.001). Sixty-one of the 87(70%) eyes experienced a myopic shift and 45(52%) eyes had a myopic shift of -0.5 dioptres or more. Mean fellow eye refraction was -0.19 dioptres preoperatively and -0.17 dioptres postoperatively (p = 0.14)(n = 37) Mean ACD preoperatively was 3.29 mm and postoperatively 3.27 mm (p = 0.53) (n = 32) and there was no significant change in ACD with tamponade use. Regression analysis revealed no statistically significant association between changes in anterior chamber depth, as well as a wide variety of other pre-, intra and postoperative factors examined, and the refractive change observed. Conclusion Significant refractive changes occur in some pseudophakic patients undergoing 20 g pars plana vitrectomy. The mean change observed was a small myopic shift but the range was large. The aetiology of the refractive change is uncertain

    Liquid-core low-refractive-index-contrast Bragg fiber sensor

    Full text link
    We propose and experimentally demonstrate a low-refractive-index-contrast hollow-core Bragg fiber sensor for liquid analyte refractive index detection. The sensor operates using a resonant sensing principle- when the refractive index of a liquid analyte in the fiber core changes, the resonant confinement of the fiber guided mode will also change, leading to both the spectral shifts and intensity changes in fiber transmission. As a demonstration, we characterize the Bragg fiber sensor using a set of NaCl solutions with different concentrations. Strong spectral shifts are obtained with the sensor experimental sensitivity found to be ~1400nm/RIU (refractive index unit). Besides, using theoretical modeling we show that low-refractive-index-contrast Bragg fibers are more suitable for liquid-analyte sensing applications than their high-refractive-index-contrast counterparts.Comment: 3 pages, 4 figure

    Design of flexible ultrahigh-Q microcavities in diamond-based photonic crystal slabs

    Full text link
    We design extremely flexible ultrahigh-Q diamond-based double-heterostructure photonic crystal slab cavities by modifying the refractive index of the diamond. The refractive index changes needed for ultrahigh-Q cavities with Q 107Q ~ 10^7, are well within what can be achieved (Δn0.02\Delta n \sim 0.02). The cavity modes have relatively small volumes V<2(λ/n)3V<2 (\lambda /n)^3, making them ideal for cavity quantum electro-dynamic applications. Importantly for realistic fabrication, our design is flexible because the range of parameters, cavity length and the index changes, that enables an ultrahigh-Q is quite broad. Furthermore as the index modification is post-processed, an efficient technique to generate cavities around defect centres is achievable, improving prospects for defect-tolerant quantum architectures.Comment: 9 pages, 4 figures (1 in colour

    The realization of an integrated Mach-Zehnder waveguide immunosensor in silicon technology

    Get PDF
    We describe the realization of a symmetric integrated channel waveguide Mach-Zehnder sensor which uses the evanescent field to detect small refractive-index changes (¿nmin ¿ 1 × 10¿4) near the guiding-layer surface. This guiding layer consists of ridge structures with a height of 3 nm and a width of 4 ¿m made in Si3N4. This layer has a thickness of 100 nm. The sensor device has been tested with glucose solutions of different bulk refractive indices. Results of a slab-model calculation are in good agreement with obtained experimental results. The feasibility of applying this sensor for immunosensing, detecting directly the binding of antigen to an antibody receptor surface, is shown with antibody-antigen binding experiments

    Polarization control and sensing with two-dimensional coupled photonic crystal microcavity arrays

    Full text link
    We have experimentally studied polarization properties of the two-dimensional coupled photonic crystal microcavity arrays, and observed a strong polarization dependence of the transmission and reflection of light from the structures - the effects that can be employed in building miniaturized polarizing optical components. Moreover, by combining these properties with a strong sensitivity of the coupled bands on the surrounding refractive index, we have demonstrated a detection of small refractive index changes in the environment, which is useful for construction of bio-chemical sensors.Comment: 8 pages text and 4 figures on 4 pages. Submitted for publication on 07/14/0
    corecore