1,352 research outputs found

    Use of radiobiological modeling in treatment plan evaluation and optimization of prostate cancer radiotherapy

    Get PDF
    There are many tools available that are used to evaluate a radiotherapy treatment plan, such as isodose distribution charts, dose volume histograms (DVH), maximum, minimum and mean doses of the dose distributions as well as DVH point dose constraints. All the already mentioned evaluation tools are dosimetric only without taking into account the radiobiological characteristics of tumors or OARs. It has been demonstrated that although competing treatment plans might have similar mean, maximum or minimum doses they may have significantly different clinical outcomes (Mavroidis et al. 2001). For performing a more complete treatment plan evaluation and comparison the complication-free tumor control probability (P+) and the biologically effective uniform dose (D ) have been proposed (Källman et al. 1992a, Mavroidis et al. 2000). The D concept denotes that any two dose distributions within a target or OAR are equivalent if they produce the same probability for tumor control or normal tissue complication, respectively (Mavroidis et al. 2001)..

    Image fusion techniques in permanent seed implantation

    Full text link

    Prostate volume delineation and seed localization using a 3-T magnetic resonance spectrometer

    Full text link
    With approximately one in six men affected by prostate cancer at some point in their lives, effective treatment of the disease remains a focus of oncology research. Effective treatment using radiation requires the delivery of a significant dose to the prostate volume while sparing surrounding sensitive structures. Treatment success can then be determined by localization of the seeds following implantation and the calculation of a dose distribution across the target volume. Magnetic Resonance Imaging (MRI) yields images with soft tissue contrast that is superior to CT or ultrasound, but has been under-appreciated as a dosimetric tool due to the difficulty in localizing the implanted seeds; To optimize scan parameters for seed localization, a phantom was constructed of tissue-equivalent gelatin. Seeds were implanted during construction so various scan protocols could be tested for seed visualization and volume calculation prior to patient studies. Five healthy volunteers and five patients with permanently implanted seeds were then imaged to validate the phantom studies. Images were evaluated based on anatomical clarity and seed visualization rates; Optimization of the scan protocols for use with this equipment yields images with clearly defined anatomical boundaries as well as clearly defined seeds. Phantom volume measurements deviated from known values by less than 2.5% T2-weighted images provide superior anatomical delineation, but suffer from broad susceptibility artifacts that make determination of seed locations difficult. Proton density-weighted images clearly show seed locations and tissue margins. The selection of a 1 mm slice thickness and a 4 mm interstice gap allowed maximum seed visualization rates of 93.3%; Keywords: prostate, brachytherapy, dosimetry, magnetic resonance imaging

    Segmentation, separation and pose estimation of prostate brachytherapy seeds in CT images.

    No full text
    International audienceIn this paper, we address the development of an automatic approach for the computation of pose information (position + orientation) of prostate brachytherapy loose seeds from 3D CT images. From an initial detection of a set of seed candidates in CT images using a threshold and connected component method, the orientation of each individual seed is estimated by using the principal components analysis (PCA) method. The main originality of this approach is the ability to classify the detected objects based on a priori intensity and volume information and to separate groups of closely spaced seeds using three competing clustering methods: the standard and a modified k-means method and a Gaussian mixture model with an Expectation-Maximization algorithm. Experiments were carried out on a series of CT images of two phantoms and patients. The fourteen patients correspond to a total of 1063 implanted seeds. Detections are compared to manual segmentation and to related work in terms of detection performance and calculation time. This automatic method has proved to be accurate and fast including the ability to separate groups of seeds in a reliable way and to determine the orientation of each seed. Such a method is mandatory to be able to compute precisely the real dose delivered to the patient post-operatively instead of assuming the alignment of seeds along the theoretical insertion direction of the brachytherapy needles

    LOW DOSE RATE PROSTATE BRACHYTHERAPY WITH OBLIQUE NEEDLES TO TREAT LARGE GLANDS AND OVERCOME PUBIC ARCH INTERFERENCE

    Get PDF
    The goal of this thesis was to evaluate the use of oblique needle trajectories in low dose rate prostate brachytherapy for large glands with pubic arch interference (PAI). A planning study was conducted with five Subject prostate contours, from 3D Transrectal Ultrasound (TRUS) images, artificially enlarged to 60 cc to increase PAI. Oblique needles no template plans (OBL) and parallel needle no template plans (PNT), were compared to parallel needle template plans for each prostate. Iodine-125 (145 Gy prescription dose), 0.43 U air kerma strength, and needle angles \u3c 15° were used. Beneficial improvements (p \u3c 0.05) in dose parameters were shown for OBL plans (all organs), and PNT plans (only PTV VI00), when compared to template plans in paired one-sided t-tests. An oblique plan was delivered to a 60 cc prostate phantom with PAI using a 3D TRUS guided mechatronic system. Seed placement accuracy was sub-millimeter in all directions

    A 3D US Guidance System for Permanent Breast Seed Implantation: Development and Validation

    Get PDF
    Permanent breast seed implantation (PBSI) is a promising breast radiotherapy technique that suffers from operator dependence. We propose and have developed an intraoperative 3D ultrasound (US) guidance system for PBSI. A tracking arm mounted to a 3D US scanner registers a needle template to the image. Images were validated for linear and volumetric accuracy, and image quality in a volunteer. The tracking arm was calibrated, and the 3D image registered to the scanner. Tracked and imaged needle positions were compared to assess accuracy and a patient-specific phantom procedure guided with the system. Median/mean linear and volumetric error was ±1.1% and ±4.1%, respectively, with clinically suitable volunteer scans. Mean tracking arm error was 0.43mm and 3D US target registration error ≤0.87mm. Mean needle tip/trajectory error was 2.46mm/1.55°. Modelled mean phantom procedure seed displacement was 2.50mm. To our knowledge, this is the first reported PBSI phantom procedure with intraoperative 3D image guidance

    Encapsulated Contrast Agent Markers for MRI-based Post-implant Dosimetry

    Get PDF
    Low-dose-rate prostate brachytherapy involves the implantation of tiny radioactive seeds into the prostate to treat prostate cancer. The current standard post-implant imaging modality is computed tomography (CT). On CT images, the radioactive seeds can be distinctively localized but delineation of the prostate and surrounding soft tissue is poor. Magnetic resonance imaging (MRI) provides better prostate and soft tissue delineation, but seed localization is difficult. To aid with seed localization, MRI markers with encapsulated contrast agent that provide positive-contrast on MRI images (Sirius MRI markers; C4 Imaging, Houston, TX) have been proposed to be placed adjacent to the negative-contrast seeds. This dissertation describes the development of the Sirius MRI markers for prostate post-implant dosimetry. First, I compared the dose-volume histogram and other dosimetry parameters generated by MIM Symphony (a brachytherapy treatment planning system that allow the use of MRI images for treatment planning; MIM Software Inc., Cleveland, OH) and VariSeed (a widely used brachytherapy treatment planning system; Varian Medical Systems, Inc., Palo Alto, CA), and found the dosimetry between both brachytherapy treatment planning systems to be comparable. To gain more insight into the MRI contrast characteristics of the Sirius MRI markers, I measured the Sirius MRI marker contrast agent\u27s spin-lattice and spin-spin relaxivities, and studied the relaxation characteristics\u27 dependence on MRI field strength, temperature, and orientation. From the Sirius MRI marker\u27s contrast agent relaxation characteristics, I systematically studied the effect of varying MRI scan parameters such as flip angle, number of excitations, bandwidth, field of view, slice thickness, and encoding steps, on the Sirius MRI markers\u27 signal and contrast, as well as image noise, artifact and scan time. On patients implanted with Sirius MRI markers, I evaluated the visibility of the Sirius MRI markers and image artifacts. Lastly, I semi-automated the localization of markers and seeds to more enable the efficient incorporation of Sirius MRI markers as part of the clinical post-implant workflow. Ultimately, the Sirius MRI markers may change the paradigm from CT-based to MRI-based post-implant dosimetry, for a more accurate understanding of dose-response relationships in patients undergoing low dose rate prostate brachytherapy

    Source placement error for permanent implant of the prostate

    Full text link
    Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/134896/1/mp8058.pd
    • …
    corecore