PEAR: PEriodic And fixed Rank separation for fast fMRI
In functional MRI (fMRI), faster acquisition via undersampling of data can
improve the spatial-temporal resolution trade-off and increase statistical
robustness through increased degrees-of-freedom. High quality reconstruction of
fMRI data from undersampled measurements requires proper modeling of the data.
We present an fMRI reconstruction approach based on modeling the fMRI signal as
a sum of periodic and fixed rank components, for improved reconstruction from
undersampled measurements. We decompose the fMRI signal into a component which
a has fixed rank and a component consisting of a sum of periodic signals which
is sparse in the temporal Fourier domain. Data reconstruction is performed by
solving a constrained problem that enforces a fixed, moderate rank on one of
the components, and a limited number of temporal frequencies on the other. Our
approach is coined PEAR - PEriodic And fixed Rank separation for fast fMRI.
Experimental results include purely synthetic simulation, a simulation with
real timecourses and retrospective undersampling of a real fMRI dataset.
Evaluation was performed both quantitatively and visually versus ground truth,
comparing PEAR to two additional recent methods for fMRI reconstruction from
undersampled measurements. Results demonstrate PEAR's improvement in estimating
the timecourses and activation maps versus the methods compared against at
acceleration ratios of R=8,16 (for simulated data) and R=6.66,10 (for real
data). PEAR results in reconstruction with higher fidelity than when using a
fixed-rank based model or a conventional Low-rank+Sparse algorithm. We have
shown that splitting the functional information between the components leads to
better modeling of fMRI, over state-of-the-art methods
Accelerated High-Resolution Photoacoustic Tomography via Compressed Sensing
Current 3D photoacoustic tomography (PAT) systems offer either high image
quality or high frame rates but are not able to deliver high spatial and
temporal resolution simultaneously, which limits their ability to image dynamic
processes in living tissue. A particular example is the planar Fabry-Perot (FP)
scanner, which yields high-resolution images but takes several minutes to
sequentially map the photoacoustic field on the sensor plane, point-by-point.
However, as the spatio-temporal complexity of many absorbing tissue structures
is rather low, the data recorded in such a conventional, regularly sampled
fashion is often highly redundant. We demonstrate that combining variational
image reconstruction methods using spatial sparsity constraints with the
development of novel PAT acquisition systems capable of sub-sampling the
acoustic wave field can dramatically increase the acquisition speed while
maintaining a good spatial resolution: First, we describe and model two general
spatial sub-sampling schemes. Then, we discuss how to implement them using the
FP scanner and demonstrate the potential of these novel compressed sensing PAT
devices through simulated data from a realistic numerical phantom and through
measured data from a dynamic experimental phantom as well as from in-vivo
experiments. Our results show that images with good spatial resolution and
contrast can be obtained from highly sub-sampled PAT data if variational image
reconstruction methods that describe the tissues structures with suitable
sparsity-constraints are used. In particular, we examine the use of total
variation regularization enhanced by Bregman iterations. These novel
reconstruction strategies offer new opportunities to dramatically increase the
acquisition speed of PAT scanners that employ point-by-point sequential
scanning as well as reducing the channel count of parallelized schemes that use
detector arrays.Comment: submitted to "Physics in Medicine and Biology
- …