4 research outputs found

    Multi-point STM: Effects of Drawing Speed and Number of Focal Points on Users’ Responses using Ultrasonic Mid-Air Haptics

    Get PDF
    Spatiotemporal modulation (STM) is used to render tactile patterns with ultrasound arrays. Previous research only explored the effects of single-point STM parameters, such as drawing speed (Vd). Here we explore the effects of multi-point STM on both perceptual (intensity) and emotional (valence/arousal) responses. This introduces a new control parameter for STM - the number of focal points (Nfp) – on top of conventional STM parameter (Vd). Our results from a study with 30 participants showed a negative effect of Nfp on perceived intensity and arousal, but no significant effects on valence. We also found the effects of Vd still aligned with prior results for single-point, even when different Nfp were used, suggesting that effects observed from single-point also apply to multi-point STM. We finally derive recommendations, such as using single-point STM to produce stimuli with higher intensity and/or arousal, or using multi-point STM for milder and more relaxing (less arousing) experience

    Measuring tactile sensitivity and mixed-reality-assisted exercise for carpal tunnel syndrome by ultrasound mid-air haptics

    Get PDF
    IntroductionCarpal tunnel syndrome (CTS) is the most common nerve entrapment neuropathy, which causes numbness and pain in the thumb, the index and middle fingers and the radial side of the ring finger. Regular hand exercises may improve the symptoms and prevent carpal tunnel surgery. This study applied a novel ultrasonic stimulation method to test tactile sensitivity in CTS and also a mixed-reality-assisted (MR-assisted) exercise program which measured hand movements and provided haptic feedback for rehabilitation.MethodsTwenty patients with mild unilateral CTS took part in the experiments. A mid-air haptics device (Ultrahaptics STRATOS Explore) was used to apply amplitude-modulated ultrasound waves (carrier frequency: 40 kHz) onto the skin to create tactile stimulation mechanically. Participants performed a two-alternative forced-choice task for measuring tactile thresholds at 250-Hz modulation frequency. They were tested at the index fingers and the thenar eminences of both hands. Additionally, 15 CTS patients used an MR-assisted program to do hand exercises with haptic feedback. Exercise performance was assessed by calculating errors between target and actual hand configurations. System Usability Scale (SUS) was adopted to verify the practical usability of the program.ResultsThresholds at the thenar eminences of the affected and healthy hands were not significantly different. While the thresholds at the healthy index fingers could be measured, those of the affected fingers were all higher than the stimulation level produced by the maximum output from the ultrasound device. In the exercise program, a significant positive correlation (ρ = 0.89, p < 0.001) was found between the performance scores and the SUS scores, which were above the criterion value established in the literature.DiscussionThe results show that thenar tactile sensitivity is not affected in mild CTS as expected from the palmar cutaneous branch of the median nerve (PCBm), but index finger threshold is likely to be higher. Overall, this study suggests that mid-air haptics, with certain improvements, may be used as a preliminary test in the clinical setting. Moreover, the device is promising to develop gamified rehabilitation programs and for the treatment follow-up of CTS
    corecore