3 research outputs found

    The influence of geometrical shapes of stenosis on the blood flow in stenosed artery

    Get PDF
    The present work was carried out to investigate the blood flow behavior and the severity of blockage caused in the arterial passage due to the different geometries such as elliptical, trapezium and triangular shapes of stenosis. The study was conducted with respect to various sizes of stenosis in terms of 70%, 80% and 90% area blockage of the arterial blood flow. The study was carried out numerically with the help of advance computational fluid dynamic software. It was found that the shape of the stenosis plays an important role in overall pressure drop across the blockage region of artery. The highest level of pressure drop was observed for trapezoidal shape of stenosis followed by elliptical and then by triangular shaped stenosis. The wall shear stress across the stenosis is great for trapezoidal shape followed by triangular and elliptical stenosis for same blockage area in the artery

    The impact of patient-specific vascular structure on localized cooling in the human heart

    Get PDF
    Acute Myocardial Infarction (AMI) is the leading cause of worldwide death and disability, and approximately 720,000 Americans will experience an AMI in 2018. Studies have shown that rapid hypothermia therapy (\u3c35°C) before reperfusion in patients with AMI can reduce infarct size by 37%. Localized therapeutic hypothermia has proven the potential to cool heart tissue rapidly following AMI, 3°C in 5 minutes. Using Materialise Mimics digital imaging software and the finite volume method we analyzed temperature distributions in six patient-specific left main coronary artery (LMCA) models. A mock circulatory loop was used to determine the exiting temperatures of a standard 7 Fr catheter to feed into our model with flow rates ranging from 29.2 ml/min to 68.85 ml/min. Our work showed that therapeutic hypothermia (TH) temperatures were evident at the outlets of three out of all six heart models, which varied in each left anterior descending (LAD) and left circumflex (LCX) artery depending on flowrate. Results of this study indicate that biovariability in patient-specific vascular structures significantly impacts therapeutic hypothermia (TH) treatment methods. These results indicate that further research is needed to examine more accurate physiological effects, such as pulsatile flow and vessel wall thickness. Future models will be used to provide insight to guide more efficient TH device designs and operation parameters to optimize patient outcomes following AMI
    corecore