65,310 research outputs found
Integrated ultrasonic particle positioning and low excitation light fluorescence imaging
A compact hybrid system has been developed to position and detect fluorescent micro-particles by combining a Single Photon Avalanche Diode (SPAD) imager with an acoustic manipulator. The detector comprises a SPAD array, light-emitting diode (LED), lenses, and optical filters. The acoustic device is formed of multiple transducers surrounding an octagonal cavity. By stimulating pairs of transducers simultaneously, an acoustic landscape is created causing fluorescent micro-particles to agglomerate into lines. The fluorescent pattern is excited by a low power LED and detected by the SPAD imager. Our technique combines particle manipulation and visualization in a compact, low power, portable setup
On the nature of the extremely fast optical rebrightening of the afterglow of GRB 081029
Context. After the launch of the Swift satellite, the Gamma-Ray Burst (GRB)
optical light-curve smoothness paradigm has been questioned thanks to the
faster and better sampled optical follow-up, which has unveiled a very complex
behaviour. This complexity is triggering the interest of the whole GRB
community. The GROND multi-channel imager is used to study optical and
near-infrared (NIR) afterglows of GRBs with unprecedented optical and
near-infrared temporal and spectral resolution. The GRB 081029 has a very
prominent optical rebrightening event and is an outstanding example of the
application of the multi-channel imager to GRB afterglows. Aims. Here we
exploit the rich GROND multi-colour follow-up of GRB 081029 combined with XRT
observations to study the nature of late-time rebrightenings that appear in the
optical-NIR light-curves of some GRB afterglows. Methods. We analyse the
optical and NIR observations obtained with the seven-channel Gamma-Ray burst
Optical and Near-infrared Detector (GROND) at the 2.2 m MPI/ESO telescope and
the X-ray data obtained with the XRT telescope on board the Swift observatory.
The multi-wavelength temporal and spectral evolution is discussed in the
framework of different physical models. Results. The extremely steep optical
and NIR rebrightening observed in GRB 081029 cannot be explained in the
framework of the standard forward shock afterglow model. The absence of a
contemporaneous X-ray rebrightening and the evidence of a strong spectral
evolution in the optical-NIR bands during the rise suggest two separate
components that dominate in the early and late-time lightcurves, respectively.
The steepness of the optical rise cannot be explained even in the framework of
the alternative scenarios proposed in the literature unless a late-time
activity of the central engine is assumed.Comment: 9 pages, 7 figures, accepted for publication in Astronomy and
Astrophysic
The Infrared Imaging Spectrograph (IRIS) for TMT: optical design of IRIS imager with "Co-axis double TMA"
IRIS (InfraRed Imaging Spectrograph) is one of the first-generation
instruments for the Thirty Meter Telescope (TMT). IRIS is composed of a
combination of near-infrared (0.84--2.4 m) diffraction limited imager and
integral field spectrograph. To achieve near-diffraction limited resolutions in
the near-infrared wavelength region, IRIS uses the advanced adaptive optics
system NFIRAOS (Narrow Field Infrared Adaptive Optics System) and integrated
on-instrument wavefront sensors (OIWFS). However, IRIS itself has challenging
specifications. First, the overall system wavefront error should be less than
40 nm in Y, z, J, and H-band and 42 nm in K-band over a 34.0 34.0
arcsecond field of view. Second, the throughput of the imager components should
be more than 42 percent. To achieve the extremely low wavefront error and high
throughput, all reflective design has been newly proposed. We have adopted a
new design policy called "Co-Axis double-TMA", which cancels the asymmetric
aberrations generated by "collimator/TMA" and "camera/TMA" efficiently. The
latest imager design meets all specifications, and, in particular, the
wavefront error is less than 17.3 nm and throughput is more than 50.8 percent.
However, to meet the specification of wavefront error and throughput as built
performance, the IRIS imager requires both mirrors with low surface
irregularity after high-reflection coating in cryogenic and high-level Assembly
Integration and Verification (AIV). To deal with these technical challenges, we
have done the tolerance analysis and found that total pass rate is almost 99
percent in the case of gauss distribution and more than 90 percent in the case
of parabolic distribution using four compensators. We also have made an AIV
plan and feasibility check of the optical elements. In this paper, we will
present the details of this optical system.Comment: 18 pages, 14 figures, Proceeding 9908-386 of the SPIE Astronomical
Telescopes + Instrumentation 201
RETROCAM: A Versatile Optical Imager for Synoptic Studies
We present RETROCAM, an auxiliary CCD camera that can be rapidly inserted
into the optical beam of the MDM 2.4m telescope. The speed and ease of
reconfiguring the telescope to use the imager and a straightforward user
interface permit the camera to be used during the course of other observing
programs. This in turn encourages RETROCAM's use for a variety of monitoring
projects.Comment: 6 pages, 6 figures, Accepted by A
A millimeter-wave kinetic inductance detector camera for long-range imaging through optical obscurants
Millimeter-wave imaging provides a promising option for long-range target detection through optical obscurants such as fog, which often occur in marine environments. Given this motivation, we are currently developing a 150 GHz polarization-sensitive imager using a relatively new type of superconducting pair-breaking detector, the kinetic inductance detector (KID). This imager will be paired with a 1.5 m telescope to obtain an angular resolution of 0.09° over a 3.5° field of view using 3,840 KIDs. We have fully characterized a prototype KID array, which shows excellent performance with noise strongly limited by the irreducible fluctuations from the ambient temperature background. Full-scale KID arrays are now being fabricated and characterized for a planned demonstration in a maritime environment later this year
Recommended from our members
A 25 micron-thin microscope for imaging upconverting nanoparticles with NIR-I and NIR-II illumination.
Rationale: Intraoperative visualization in small surgical cavities and hard-to-access areas are essential requirements for modern, minimally invasive surgeries and demand significant miniaturization. However, current optical imagers require multiple hard-to-miniaturize components including lenses, filters and optical fibers. These components restrict both the form-factor and maneuverability of these imagers, and imagers largely remain stand-alone devices with centimeter-scale dimensions. Methods: We have engineered INSITE (Immunotargeted Nanoparticle Single-Chip Imaging Technology), which integrates the unique optical properties of lanthanide-based alloyed upconverting nanoparticles (aUCNPs) with the time-resolved imaging of a 25-micron thin CMOS-based (complementary metal oxide semiconductor) imager. We have synthesized core/shell aUCNPs of different compositions and imaged their visible emission with INSITE under either NIR-I and NIR-II photoexcitation. We characterized aUCNP imaging with INSITE across both varying aUCNP composition and 980 nm and 1550 nm excitation wavelengths. To demonstrate clinical experimental validity, we also conducted an intratumoral injection into LNCaP prostate tumors in a male nude mouse that was subsequently excised and imaged with INSITE. Results: Under the low illumination fluences compatible with live animal imaging, we measure aUCNP radiative lifetimes of 600 μs - 1.3 ms, which provides strong signal for time-resolved INSITE imaging. Core/shell NaEr0.6Yb0.4F4 aUCNPs show the highest INSITE signal when illuminated at either 980 nm or 1550 nm, with signal from NIR-I excitation about an order of magnitude brighter than from NIR-II excitation. The 55 μm spatial resolution achievable with this approach is demonstrated through imaging of aUCNPs in PDMS (polydimethylsiloxane) micro-wells, showing resolution of micrometer-scale targets with single-pixel precision. INSITE imaging of intratumoral NaEr0.8Yb0.2F4 aUCNPs shows a signal-to-background ratio of 9, limited only by photodiode dark current and electronic noise. Conclusion: This work demonstrates INSITE imaging of aUCNPs in tumors, achieving an imaging platform that is thinned to just a 25 μm-thin, planar form-factor, with both NIR-I and NIR-II excitation. Based on a highly paralleled array structure INSITE is scalable, enabling direct coupling with a wide array of surgical and robotic tools for seamless integration with tissue actuation, resection or ablation
The InfraRed Imaging Spectrograph (IRIS) for TMT: photometric precision and ghost analysis
The InfraRed Imaging Spectrograph (IRIS) is a first-light instrument for the
Thirty Meter Telescope (TMT) that will be used to sample the corrected adaptive
optics field by NFIRAOS with a near-infrared (0.8 - 2.4 m) imaging camera
and Integral Field Spectrograph (IFS). In order to understand the science case
specifications of the IRIS instrument, we use the IRIS data simulator to
characterize photometric precision and accuracy of the IRIS imager. We present
the results of investigation into the effects of potential ghosting in the IRIS
optical design. Each source in the IRIS imager field of view results in ghost
images on the detector from IRIS's wedge filters, entrance window, and
Atmospheric Dispersion Corrector (ADC) prism. We incorporated each of these
ghosts into the IRIS simulator by simulating an appropriate magnitude point
source at a specified pixel distance, and for the case of the extended ghosts
redistributing flux evenly over the area specified by IRIS's optical design. We
simulate the ghosting impact on the photometric capabilities, and found that
ghosts generally contribute negligible effects on the flux counts for point
sources except for extreme cases where ghosts coalign with a star of
m2 fainter than the ghost source. Lastly, we explore the photometric
precision and accuracy for single sources and crowded field photometry on the
IRIS imager.Comment: SPIE 2018, 14 pages, 14 figures, 4 tables, Proceedings of SPIE
10702-373, Ground-based and Airborne Instrumentation for Astronomy VII,
10702A7 (16 July 2018
The Mid-Infrared Instrument for the James Webb Space Telescope, III: MIRIM, The MIRI Imager
In this article, we describe the MIRI Imager module (MIRIM), which provides
broad-band imaging in the 5 - 27 microns wavelength range for the James Webb
Space Telescope. The imager has a 0"11 pixel scale and a total unobstructed
view of 74"x113". The remainder of its nominal 113"x113" field is occupied by
the coronagraphs and the low resolution spectrometer. We present the instrument
optical and mechanical design. We show that the test data, as measured during
the test campaigns undertaken at CEA-Saclay, at the Rutherford Appleton
Laboratory, and at the NASA Goddard Space Flight Center, indicate that the
instrument complies with its design requirements and goals. We also discuss the
operational requirements (multiple dithers and exposures) needed for optimal
scientific utilization of the MIRIM.Comment: 29 pages, 9 figure
- …
