90,616 research outputs found

    Investigating Performance and Reliability of Process Bus Networks for Digital Protective Relaying

    Get PDF
    To reduce the cost of complex and long copper wiring, as well as to achieve flexibility in signal communications, IEC 61850 part 9-2 proposes a process bus communication network between process level switchyard equipments, and bay level protection and control (P&C) Intelligent Electronic Devices (IEDs). After successful implementation of Ethernet networks for IEC 61850 standard part 8-1 (station bus) at several substations worldwide, major manufacturers are currently working on the development of interoperable products for the IEC 61850-9-2 based process bus. The major technical challenges for applying Ethernet networks at process level include: 1) the performance of time critical messages for protection applications; 2) impacts of process bus Ethernet networks on the reliability of substation protection systems. This work starts with the performance analysis in terms of time critical Sampled Value (SV) messages loss and/or delay over the IEC 61850-9-2 process bus networks of a typical substation. Unlike GOOSE, the SV message is not repeated several times, and therefore, there is no assurance that each SV message will be received from the process bus network at protection IEDs. Therefore, the detailed modeling of IEC 61850 based substation protection devices, communication protocols, and packet format is carried out using an industry-trusted simulation tool OPNET, to study and quantify number of SV loss and delay over the process bus. The impact of SV loss/delay on digital substation protection systems is evident, and recognized by several manufacturers. Therefore, a sample value estimation algorithm is developed in order to enhance the performance of digital substation protection functions by estimating the lost and delayed sampled values. The error of estimation is evaluated in detail considering several scenarios of power system relaying. The work is further carried out to investigate the possible impact of SV loss/delay on protection functions, and test the proposed SV estimation algorithm using the hardware setup. Therefore, a state-of-the-art process bus laboratory with the protection IEDs and merging unit playback simulator using industrial computers on the QNX hard-real-time platform, is developed for a typical IEC 61850-9-2 based process bus network. Moreover, the proposed SV estimation algorithm is implemented as a part of bus differential and transmission line distance protection IEDs, and it is tested using the developed experimental setup for various SV loss/delay scenarios and power system fault conditions. In addition to the performance analysis, this work also focuses on the reliability aspects of protection systems with process bus communication network. To study the impact of process bus communication on reliability indices of a substation protection function, the detailed reliability modeling and analysis is carried out for a typical substation layout. First of all, reliability analysis is done using Reliability Block Diagrams (RBD) considering various practical process bus architectures, as well as, time synchronization techniques. After obtaining important failure rates from the RBD, an extended Markov model is proposed to analyze the reliability indices of protection systems, such as, protection unavailability, abnormal unavailability, and loss of security. It is shown with the proposed Markov model that the implementation of sampled value estimation improves the reliability indices of a protection system

    Power quality and electromagnetic compatibility: special report, session 2

    Get PDF
    The scope of Session 2 (S2) has been defined as follows by the Session Advisory Group and the Technical Committee: Power Quality (PQ), with the more general concept of electromagnetic compatibility (EMC) and with some related safety problems in electricity distribution systems. Special focus is put on voltage continuity (supply reliability, problem of outages) and voltage quality (voltage level, flicker, unbalance, harmonics). This session will also look at electromagnetic compatibility (mains frequency to 150 kHz), electromagnetic interferences and electric and magnetic fields issues. Also addressed in this session are electrical safety and immunity concerns (lightning issues, step, touch and transferred voltages). The aim of this special report is to present a synthesis of the present concerns in PQ&EMC, based on all selected papers of session 2 and related papers from other sessions, (152 papers in total). The report is divided in the following 4 blocks: Block 1: Electric and Magnetic Fields, EMC, Earthing systems Block 2: Harmonics Block 3: Voltage Variation Block 4: Power Quality Monitoring Two Round Tables will be organised: - Power quality and EMC in the Future Grid (CIGRE/CIRED WG C4.24, RT 13) - Reliability Benchmarking - why we should do it? What should be done in future? (RT 15

    A Survey on Communication Networks for Electric System Automation

    Get PDF
    Published in Computer Networks 50 (2006) 877–897, an Elsevier journal. The definitive version of this publication is available from Science Direct. Digital Object Identifier:10.1016/j.comnet.2006.01.005In today’s competitive electric utility marketplace, reliable and real-time information become the key factor for reliable delivery of power to the end-users, profitability of the electric utility and customer satisfaction. The operational and commercial demands of electric utilities require a high-performance data communication network that supports both existing functionalities and future operational requirements. In this respect, since such a communication network constitutes the core of the electric system automation applications, the design of a cost-effective and reliable network architecture is crucial. In this paper, the opportunities and challenges of a hybrid network architecture are discussed for electric system automation. More specifically, Internet based Virtual Private Networks, power line communications, satellite communications and wireless communications (wireless sensor networks, WiMAX and wireless mesh networks) are described in detail. The motivation of this paper is to provide a better understanding of the hybrid network architecture that can provide heterogeneous electric system automation application requirements. In this regard, our aim is to present a structured framework for electric utilities who plan to utilize new communication technologies for automation and hence, to make the decision making process more effective and direct.This work was supported by NEETRAC under Project #04-157

    Adaptive OFDM Index Modulation for Two-Hop Relay-Assisted Networks

    Get PDF
    In this paper, we propose an adaptive orthogonal frequency-division multiplexing (OFDM) index modulation (IM) scheme for two-hop relay networks. In contrast to the traditional OFDM IM scheme with a deterministic and fixed mapping scheme, in this proposed adaptive OFDM IM scheme, the mapping schemes between a bit stream and indices of active subcarriers for the first and second hops are adaptively selected by a certain criterion. As a result, the active subcarriers for the same bit stream in the first and second hops can be varied in order to combat slow frequency-selective fading. In this way, the system reliability can be enhanced. Additionally, considering the fact that a relay device is normally a simple node, which may not always be able to perform mapping scheme selection due to limited processing capability, we also propose an alternative adaptive methodology in which the mapping scheme selection is only performed at the source and the relay will simply utilize the selected mapping scheme without changing it. The analyses of average outage probability, network capacity and symbol error rate (SER) are given in closed form for decode-and-forward (DF) relaying networks and are substantiated by numerical results generated by Monte Carlo simulations.Comment: 30 page
    • …
    corecore