13,843 research outputs found

    Numerical Simulation of Heat Transport in Dispersed Gas-Liquid Two-Phase Flow using a Front Tracking Approach

    Get PDF
    In this paper a simulation model is presented for the Direct Numerical Simulation (DNS) of heat transport in dispersed gas-liquid two-phase flow using the Front Tracking (FT) approach. Our model extends the FT model developed by van Sint Annaland et al. (2006) to non-isothermal conditions. In FT an unstructured dynamic mesh is used to represent and track the interface explicitly by a number of interconnected marker points. The Lagrangian representation of the interface avoids the necessity to reconstruct the interface from the local distribution of the fractions of the phases and, moreover, allows a direct and accurate calculation of the surface tension force circumventing the (problematic) computation of the interface curvature. The extended model is applied to predict the heat exchange rate between the liquid and a hot wall kept at a fixed temperature. It is found that the wall-to-liquid heat transfer coefficient exhibits a maximum in the vicinity of the bubble that can be attributed to the locally decreased thickness of the thermal boundary layer

    Direct numerical simulation of heat transport in dispersed gas-liquid two-phase flow using a front tracking approach

    Get PDF
    In this paper a simulation model is presented for the Direct Numerical Simulation (DNS) of heat transport in dispersed gas-liquid two-phase flow using the Front Tracking (FT) approach. Our model extends the FT model developed by van Sint Annaland et al. (2006) to non-isothermal conditions. In FT an unstructured dynamic mesh is used to represent and track the interface explicitly by a number of interconnected marker points. The Lagrangian representation of the interface avoids the necessity to reconstruct the interface from the local distribution of the fractions of the phases and, moreover, allows a direct and accurate calculation of the surface tension force circumventing the (problematic) computation of the interface curvature. The extended model is applied to predict the heat exchange rate between the liquid and a hot wall kept at a fixed temperature. It is found that the wall-to-liquid heat transfer coefficient exhibits a maximum in the vicinity of the bubble that can be attributed to the locally decreased thickness of the thermal boundary layer

    Direct Numerical Simulation of Complex Multi-Fluid Flows Using a Combined Volume of Fluid and Immersed Boundary Method

    Get PDF
    In this paper a simulation model is presented for the Direct Numerical Simulation (DNS) of complex multi-fluid flows in which simultaneously (moving) deformable (drops or bubbles) and non-deformable (moving) elements (particles) are present, possibly with the additional presence of free surfaces. Our model combines the VOF model developed by van Sint Annaland et al. (2005) and the Immersed Boundary (IB) model developed by van der Hoef et al. (2006). The Volume of Fluid (VOF) part features i) an interface reconstruction technique based on piecewise linear interface representation ii) a three-dimensional version of the CSF model of Brackbill et al. (1992). The Immersed Boundary (IB) part incorporates both particle-fluid and particle-particle interaction via a Direct Forcing Method (DFM) and a hard sphere Discrete Particle (DP) approach. In our model a fixed (Eulerian) grid is utilized to solve the Navier-Stokes equations for the entire computational domain. The no-slip condition at the surface of the moving particles is enforced via a momentum source term which only acts in the vicinity of the particle surface. For the enforcement of the no-slip condition Lagrangian force points are used which are distributed evenly over the surface of the particle. Dissipative particle-particle and/or particle-wall collisions are accounted via a hard sphere DP approach (Hoomans et al., 1996) using a three-parameter particle-particle interaction model accounting for normal and tangential restitution and tangential friction. The capabilities of the hybrid VOF-IB model are demonstrated with a number of examples in which complex topological changes in the interface are encountered

    Computational Simulations for Aortic Coarctation: Representative Results From a Sampling of Patients

    Get PDF
    Treatments for coarctation of the aorta (CoA) can alleviate blood pressure (BP) gradients(D), but long-term morbidity still exists that can be explained by altered indices of hemodynamics and biomechanics. We introduce a technique to increase our understanding of these indices for CoA under resting and nonresting conditions, quantify their contribution to morbidity, and evaluate treatment options. Patient-specific computational fluid dynamics (CFD) models were created from imaging and BP data for one normal and four CoA patients (moderate native CoA: D12 mmHg, severe native CoA: D25 mmHg and postoperative end-to-end and end-to-side patients: D0 mmHg). Simulations incorporated vessel deformation, downstream vascular resistance and compliance. Indices including cyclic strain, time-averaged wall shear stress (TAWSS), and oscillatory shear index (OSI) were quantified. Simulations replicated resting BP and blood flow data. BP during simulated exercise for the normal patient matched reported values. Greatest exercise-induced increases in systolic BP and mean and peak DBP occurred for the moderate native CoA patient (SBP: 115 to 154 mmHg; mean and peak DBP: 31 and 73 mmHg). Cyclic strain was elevated proximal to the coarctation for native CoA patients, but reduced throughout the aorta after treatment. A greater percentage of vessels was exposed to subnormal TAWSS or elevated OSI for CoA patients. Local patterns of these indices reported to correlate with atherosclerosis in normal patients were accentuated by CoA. These results apply CFD to a range of CoA patients for the first time and provide the foundation for future progress in this area

    Transient electrothermal simulation of power semiconductor devices

    Get PDF
    In this paper, a new thermal model based on the Fourier series solution of heat conduction equation has been introduced in detail. 1-D and 2-D Fourier series thermal models have been programmed in MATLAB/Simulink. Compared with the traditional finite-difference thermal model and equivalent RC thermal network, the new thermal model can provide high simulation speed with high accuracy, which has been proved to be more favorable in dynamic thermal characterization on power semiconductor switches. The complete electrothermal simulation models of insulated gate bipolar transistor (IGBT) and power diodes under inductive load switching condition have been successfully implemented in MATLAB/Simulink. The experimental results on IGBT and power diodes with clamped inductive load switching tests have verified the new electrothermal simulation model. The advantage of Fourier series thermal model over widely used equivalent RC thermal network in dynamic thermal characterization has also been validated by the measured junction temperature

    NASA scientific and technical publications: A catalog of special publications, reference publications, conference publications, and technical papers, 1989

    Get PDF
    This catalog lists 190 citations of all NASA Special Publications, NASA Reference Publications, NASA Conference Publications, and NASA Technical Papers that were entered into the NASA scientific and technical information database during accession year 1989. The entries are grouped by subject category. Indexes of subject terms, personal authors, and NASA report numbers are provided

    A Rapid and Computationally Inexpensive Method to Virtually Implant Current and Next-Generation Stents into Subject-Specific Computational Fluid Dynamics Models

    Get PDF
    Computational modeling is often used to quantify hemodynamic alterations induced by stenting, but frequently uses simplified device or vascular representations. Based on a series of Boolean operations, we developed an efficient and robust method for assessing the influence of current and next-generation stents on local hemodynamics and vascular biomechanics quantified by computational fluid dynamics. Stent designs were parameterized to allow easy control over design features including the number, width and circumferential or longitudinal spacing of struts, as well as the implantation diameter and overall length. The approach allowed stents to be automatically regenerated for rapid analysis of the contribution of design features to resulting hemodynamic alterations. The applicability of the method was demonstrated with patient-specific models of a stented coronary artery bifurcation and basilar trunk aneurysm constructed from medical imaging data. In the coronary bifurcation, we analyzed the hemodynamic difference between closed-cell and open-cell stent geometries. We investigated the impact of decreased strut size in stents with a constant porosity for increasing flow stasis within the stented basilar aneurysm model. These examples demonstrate the current method can be used to investigate differences in stent performance in complex vascular beds for a variety of stenting procedures and clinical scenarios

    Computational simulations demonstrate altered wall shear stress in aortic coarctation patients previously treated by resection with end-to-end anastomosis

    Get PDF
    Background.  Atherosclerotic plaque in the descending thoracic aorta (dAo) is related to altered wall shear stress (WSS) for normal patients. Resection with end-to-end anastomosis (RWEA) is the gold standard for coarctation of the aorta (CoA) repair, but may lead to altered WSS indices that contribute to morbidity. Methods.  Computational fluid dynamics (CFD) models were created from imaging and blood pressure data for control subjects and age- and gender-matched CoA patients treated by RWEA (four males, two females, 15 ± 8 years). CFD analysis incorporated downstream vascular resistance and compliance to generate blood flow velocity, time-averaged WSS (TAWSS), and oscillatory shear index (OSI) results. These indices were quantified longitudinally and circumferentially in the dAo, and several visualization methods were used to highlight regions of potential hemodynamic susceptibility. Results.  The total dAo area exposed to subnormal TAWSS and OSI was similar between groups, but several statistically significant local differences were revealed. Control subjects experienced left-handed rotating patterns of TAWSS and OSI down the dAo. TAWSS was elevated in CoA patients near the site of residual narrowings and OSI was elevated distally, particularly along the left dAo wall. Differences in WSS indices between groups were negligible more than 5 dAo diameters distal to the aortic arch. Conclusions.  Localized differences in WSS indices within the dAo of CoA patients treated by RWEA suggest that plaque may form in unique locations influenced by the surgical repair. These regions can be visualized in familiar and intuitive ways allowing clinicians to track their contribution to morbidity in longitudinal studies
    corecore