9,122 research outputs found
A closed-form solution to estimate uncertainty in non-rigid structure from motion
Semi-Definite Programming (SDP) with low-rank prior has been widely applied
in Non-Rigid Structure from Motion (NRSfM). Based on a low-rank constraint, it
avoids the inherent ambiguity of basis number selection in conventional
base-shape or base-trajectory methods. Despite the efficiency in deformable
shape reconstruction, it remains unclear how to assess the uncertainty of the
recovered shape from the SDP process. In this paper, we present a statistical
inference on the element-wise uncertainty quantification of the estimated
deforming 3D shape points in the case of the exact low-rank SDP problem. A
closed-form uncertainty quantification method is proposed and tested. Moreover,
we extend the exact low-rank uncertainty quantification to the approximate
low-rank scenario with a numerical optimal rank selection method, which enables
solving practical application in SDP based NRSfM scenario. The proposed method
provides an independent module to the SDP method and only requires the
statistic information of the input 2D tracked points. Extensive experiments
prove that the output 3D points have identical normal distribution to the 2D
trackings, the proposed method and quantify the uncertainty accurately, and
supports that it has desirable effects on routinely SDP low-rank based NRSfM
solver.Comment: 9 pages, 2 figure
Magnetic resonance multitasking for motion-resolved quantitative cardiovascular imaging.
Quantitative cardiovascular magnetic resonance (CMR) imaging can be used to characterize fibrosis, oedema, ischaemia, inflammation and other disease conditions. However, the need to reduce artefacts arising from body motion through a combination of electrocardiography (ECG) control, respiration control, and contrast-weighting selection makes CMR exams lengthy. Here, we show that physiological motions and other dynamic processes can be conceptualized as multiple time dimensions that can be resolved via low-rank tensor imaging, allowing for motion-resolved quantitative imaging with up to four time dimensions. This continuous-acquisition approach, which we name cardiovascular MR multitasking, captures - rather than avoids - motion, relaxation and other dynamics to efficiently perform quantitative CMR without the use of ECG triggering or breath holds. We demonstrate that CMR multitasking allows for T1 mapping, T1-T2 mapping and time-resolved T1 mapping of myocardial perfusion without ECG information and/or in free-breathing conditions. CMR multitasking may provide a foundation for the development of setup-free CMR imaging for the quantitative evaluation of cardiovascular health
- …