8,904 research outputs found

    Automated mixed traffic transit vehicle microprocessor controller

    Get PDF
    An improved Automated Mixed Traffic Vehicle (AMTV) speed control system employing a microprocessor and transistor chopper motor current controller is described and its performance is presented in terms of velocity versus time curves. The on board computer hardware and software systems are described as is the software development system. All of the programming used in this controller was implemented using FORTRAN. This microprocessor controller made possible a number of safety features and improved the comfort associated with starting and shopping. In addition, most of the vehicle's performance characteristics can be altered by simple program parameter changes. A failure analysis of the microprocessor controller was generated and the results are included. Flow diagrams for the speed control algorithms and complete FORTRAN code listings are also included

    Extending the Life-Cycle of Optical Media

    Get PDF
    This paper examines the products that two companies provide to protect optical media and to eliminate scratches, gauges, and other marks that deface the playing surface

    A long-range and long-life telemetry data-acquisition system for heart rate and multiple body temperatures from free-ranging animals

    Get PDF
    The system includes an implantable transmitter, external receiver-retransmitter collar, and a microprocessor-controlled demodulator. The size of the implant is suitable for animals with body weights of a few kilograms or more; further size reduction of the implant is possible. The ECG is sensed by electrodes designed for internal telemetry and to reduce movement artifacts. The R-wave characteristics are then specifically selected to trigger a short radio frequency pulse. Temperatures are sensed at desired locations by thermistors and then, based on a heartbeat counter, transmitted intermittently via pulse interval modulation. This modulation scheme includes first and last calibration intervals for a reference by ratios with the temperature intervals to achieve good accuracy even over long periods. Pulse duration and pulse sequencing are used to discriminate between heart rate and temperature pulses as well as RF interference

    Microbial load monitor

    Get PDF
    A card configuration which combines the functions of identification, enumeration and antibiotic sensitivity into one card was developed. An instrument package was designed around the card to integrate the card filling, incubation reading, computation and decision making process into one compact unit. Support equipment was also designed to prepare the expandable material used in the MLM

    Control system for a superconducting rectifier using a microcomputer

    Get PDF
    Within the scope of a research program of superconducting rectifiers software is being developed to take care of the control of such systems. The hard-ware architecture which interferes with the in and output signals is based on a LSI-11/2 microprocessor with sufficient mass storage for data logging, console and printer. The flexibility inherent to this hardware configuration is desired for optimalisation of the rectifier concerning maximum current, power, efficiency and quench stability. The paper describes the structure of the program and the interaction between both computer hardware and software and the superconducting rectifier. However, because the reliability of computersystems is unsatisfactory an additional hardware protection system still handles the most important alarms

    Mod-2 wind turbine system concept and preliminary design report. Volume 1: Executive summary

    Get PDF
    The configuration development of the MOD-2 wind turbine system is presented. The MOD-2 is design optimized for commercial production rates which, in multi-unit installations, will be integrated into a utility power grid and achieve a cost of electricity at less than 4 cents per kilowatt hour

    Advanced Transport Operating System (ATOPS) color displays software description: MicroVAX system

    Get PDF
    This document describes the software created for the Display MicroVAX computer used for the Advanced Transport Operating Systems (ATOPS) project on the Transport Systems Research Vehicle (TSRV). The software delivery of February 27, 1991, known as the 'baseline display system', is the one described in this document. Throughout this publication, module descriptions are presented in a standardized format which contains module purpose, calling sequence, detailed description, and global references. The global references section includes subroutines, functions, and common variables referenced by a particular module. The system described supports the Research Flight Deck (RFD) of the TSRV. The RFD contains eight Cathode Ray Tubes (CRTs) which depict a Primary Flight Display, Navigation Display, System Warning Display, Takeoff Performance Monitoring System Display, and Engine Display

    A digital imaging photometry system for cometary data acquisition

    Get PDF
    This report describes a digital imaging photometry system developed in the Space Science Laboratory at the Marshall Space Flight center. The photometric system used for cometary data acquisition is based on an intensified secondary electron conduction (ISEC) vidicon coupled to a versatile data acquisition system which allows real-time interactive operation. Field tests on the Orion and Rosette nebulas indicate a limiting magnitude of approximately m sub v = 14 over the 40 arcmin field-of-view. Observations were conducted of Comet Giacobini-Zinner in August 1985. The resulting data are discussed in relation to the capabilities of the digital analysis system. The development program concluded on August 31, 1985
    corecore