2,523 research outputs found
Frequency-modulated continuous-wave LiDAR compressive depth-mapping
We present an inexpensive architecture for converting a frequency-modulated
continuous-wave LiDAR system into a compressive-sensing based depth-mapping
camera. Instead of raster scanning to obtain depth-maps, compressive sensing is
used to significantly reduce the number of measurements. Ideally, our approach
requires two difference detectors. % but can operate with only one at the cost
of doubling the number of measurments. Due to the large flux entering the
detectors, the signal amplification from heterodyne detection, and the effects
of background subtraction from compressive sensing, the system can obtain
higher signal-to-noise ratios over detector-array based schemes while scanning
a scene faster than is possible through raster-scanning. %Moreover, we show how
a single total-variation minimization and two fast least-squares minimizations,
instead of a single complex nonlinear minimization, can efficiently recover
high-resolution depth-maps with minimal computational overhead. Moreover, by
efficiently storing only data points from measurements of an
pixel scene, we can easily extract depths by solving only two linear equations
with efficient convex-optimization methods
Deep learning in computational microscopy
We propose to use deep convolutional neural networks (DCNNs) to perform 2D and 3D computational imaging. Specifically, we investigate three different applications. We first try to solve the 3D inverse scattering problem based on learning a huge number of training target and speckle pairs. We also demonstrate a new DCNN architecture to perform Fourier ptychographic Microscopy (FPM) reconstruction, which achieves high-resolution phase recovery with considerably less data than standard FPM. Finally, we employ DCNN models that can predict focused 2D fluorescent microscopic images from blurred images captured at overfocused or underfocused planes.Published versio
Accelerated High-Resolution Photoacoustic Tomography via Compressed Sensing
Current 3D photoacoustic tomography (PAT) systems offer either high image
quality or high frame rates but are not able to deliver high spatial and
temporal resolution simultaneously, which limits their ability to image dynamic
processes in living tissue. A particular example is the planar Fabry-Perot (FP)
scanner, which yields high-resolution images but takes several minutes to
sequentially map the photoacoustic field on the sensor plane, point-by-point.
However, as the spatio-temporal complexity of many absorbing tissue structures
is rather low, the data recorded in such a conventional, regularly sampled
fashion is often highly redundant. We demonstrate that combining variational
image reconstruction methods using spatial sparsity constraints with the
development of novel PAT acquisition systems capable of sub-sampling the
acoustic wave field can dramatically increase the acquisition speed while
maintaining a good spatial resolution: First, we describe and model two general
spatial sub-sampling schemes. Then, we discuss how to implement them using the
FP scanner and demonstrate the potential of these novel compressed sensing PAT
devices through simulated data from a realistic numerical phantom and through
measured data from a dynamic experimental phantom as well as from in-vivo
experiments. Our results show that images with good spatial resolution and
contrast can be obtained from highly sub-sampled PAT data if variational image
reconstruction methods that describe the tissues structures with suitable
sparsity-constraints are used. In particular, we examine the use of total
variation regularization enhanced by Bregman iterations. These novel
reconstruction strategies offer new opportunities to dramatically increase the
acquisition speed of PAT scanners that employ point-by-point sequential
scanning as well as reducing the channel count of parallelized schemes that use
detector arrays.Comment: submitted to "Physics in Medicine and Biology
Detail-preserving and Content-aware Variational Multi-view Stereo Reconstruction
Accurate recovery of 3D geometrical surfaces from calibrated 2D multi-view
images is a fundamental yet active research area in computer vision. Despite
the steady progress in multi-view stereo reconstruction, most existing methods
are still limited in recovering fine-scale details and sharp features while
suppressing noises, and may fail in reconstructing regions with few textures.
To address these limitations, this paper presents a Detail-preserving and
Content-aware Variational (DCV) multi-view stereo method, which reconstructs
the 3D surface by alternating between reprojection error minimization and mesh
denoising. In reprojection error minimization, we propose a novel inter-image
similarity measure, which is effective to preserve fine-scale details of the
reconstructed surface and builds a connection between guided image filtering
and image registration. In mesh denoising, we propose a content-aware
-minimization algorithm by adaptively estimating the value and
regularization parameters based on the current input. It is much more promising
in suppressing noise while preserving sharp features than conventional
isotropic mesh smoothing. Experimental results on benchmark datasets
demonstrate that our DCV method is capable of recovering more surface details,
and obtains cleaner and more accurate reconstructions than state-of-the-art
methods. In particular, our method achieves the best results among all
published methods on the Middlebury dino ring and dino sparse ring datasets in
terms of both completeness and accuracy.Comment: 14 pages,16 figures. Submitted to IEEE Transaction on image
processin
- …